Service Manual FL 40-CrossPointer SP 

2.2.3 Curving error 

The laser line is curving to the reference line relatively, this error is curving error.(Figure 5) 

 

                                                                Figure 5 

2.2.3.1 Calibration of curving error of horizontal laser line 

1

Put the instrument on the reference platform. Power on all laser indicators. 

2

Rotate the upper part of the unit, let the vertical laser line V is coincident with the reference line 

3

Observe the locations of the laser line and reference line on the wall. If the horizontal laser line and the 

reference line are curving relatively, i.e. curving error, please calibrate as the follow methods: 

Disassemble  the  housing  parts  firstly,  adjust  the  two  screws  on  point  G  (figure  3).  When  adjust  the  two 

screws  on  point G,  it  need  to loosen  one  screw  before  tighten  another  screw,  until  the  horizontal  laser  line 

icoincident  with  the  reference  line.  The  degrees  of  tightness  of  the  two  screws  should  be  nearly  the  same 

finally. 

 

2.2.3.2 Calibration of curving error of vertical laser line   

1

Put the instrument on the reference platform. Power on all laser indicators. 

2

Rotate the unit, let the vertical laser line V is coincident with the reference line. 

3

Observe  the  locations  of  the  laser  line  and  reference  line  on  the  wall.  If  the  vertical  laser  line  and  the 

vertical reference line are curving relatively, i.e. curving error, please calibrate as the follow methods: 

Disassemble  the  housing  parts  at  first,  adjust  the  two  screws  on  point  F  (figure  3).  When  adjust  the  two 

screws  on  point  F,  it  need  to  loosen  one  screw  before  tighten  another  screw,  until  the  vertical  laser  line  is 

coincident  with the vertical  reference line. The degrees of tightness of the two screws should be nearly  the 

same finally. 

 

 

 

 

Содержание Selection PRO FLG 40-PowerCross GREEN SP

Страница 1: ...FL 40 PowerCross SP Service Manual...

Страница 2: ...instrument 2 Accuracy calibration 2 1 Setting the reference 2 2 Sort of the error and calibration methods 3 Adjustment for alarming range 4 Disassembly and assembly of the instrument 4 1 Disassembly...

Страница 3: ...The hairspring is broken 3 The 1 controling PCB is broken 1 Jointing the broken connecting line 2 Change the broken hairspring 3 Change 1 circuit board Laser line is dim The laser diode is broken Cha...

Страница 4: ...adjacent light ruler to the right front of the adjusting platform the 0 position Of the adjacent light ruler should be consistent with the horizontal reference 0 position 2 2 Sort of the error and cal...

Страница 5: ...10mm adjust the adjusting screw in two self check hole on point A on the housing of the instrument figure 3 make the horizontal laser line is coincident with the reference line Figure 3 2 2 1 1 2 If...

Страница 6: ...figure 3 When adjust the two screws on point D it need to loosen one screw before tighten another screw until the horizontal laser line is coincident with the reference line The degrees of tightness o...

Страница 7: ...one screw before tighten another screw until the horizontal laser line icoincident with the reference line The degrees of tightness of the two screws should be nearly the same finally 2 2 3 2 Calibrat...

Страница 8: ...3 13 Then move 3 connecting PC board in horizontal make the alarming pole of 2 alarming PC board 3 13 locate in the centre of the alarming ring then fasten the screws When the incline degree of any di...

Страница 9: ...th a cutter 1 1 2 Use a cross screwdriver to turn off 4 pcs cross head plate tapping screw ST2 2x5 1 4 and take off 1 operation PC board G609 1 operation PC board 1 3 3 Pull a little harder to move of...

Страница 10: ...1 by a cross srewdriver move off 4 alarming PCB G609 4 alarming PCB 3 4 6 Screw off 1 pc of cross head plate screw M2X10 3 9 by a cross srewdriver move off horizontal laser module green laser module...

Страница 11: ...ery cover part 4 9 3 Use electric iron to burn down the leading line of the power supply plug move off the contacting part 4 6 4 Screw off 3 pcs of nut M2 5 4 2 by a cross srewdriver move off 6 pcs of...

Страница 12: ...board 6 15 6 1 Lifting bracket 6 2 Locking sheet 2 6 3 Damping bracket 6 4 Cross head plate tapping screw ST2 2X5 5 6 5 Locking ring 5 6 6 Cam 6 7 Cross head plate tapping screw ST2 9X9 5 9 6 8 Magne...

Страница 13: ...the Locking ring 6 6 17 saperate turnplate 6 22 2 pcs of gasket 6 18 2 pcs of saddle pad 6 19 lifting bracket 6 1 7 Screw off 4 pcs of cross head plate tapping screw ST2 9X9 5 6 7 move off the base co...

Страница 14: ...showed in figure 11 connect the corresponding connecting line to each PCBs accordingly Solder 4 hairsprings to the corresponding place of4 Alarming PC board or G609 4 Alarming PC board 3 4 and 3 Conne...

Страница 15: ...that note especially Requirement of assembly a Gelatinize 706 glue water on the jointing as follows The interface between base 4 5 and inserting block 4 13 Lifting bracket 6 1 and press cover 6 21 Fin...

Отзывы: