background image

38

EN

RELATIVE 0-POSITION (REFERENCE POINT)

Within the range of ± 20 mm of the standard reference point (0-position) a relative 0-position can be 

set. Press the „0SET“ button when the laser beam hits the receiving window (the „0SET“ symbol will 

flash on the display). This current position of the laser beam is now set as the relative 0-position on the 

receiver. Press the „0SET“ button to return to the default mode. 

MM INDICATION

If the reference level of the receiver is e. g. 18 mm below the laser beam this height difference will be 

displayed by an exact numerical value (see the left diagram). 

further examples

The laser beam is 

exactly on-level.

The laser beam is 

19 mm above the 

reference point 

(move the receiver 

up).

The laser beam is 

35 mm below the 

reference point 

(move the receiver 

down).

Содержание 244045

Страница 1: ...www geo fennel com DE EN FR FL 245HV USER MANUAL ...

Страница 2: ...arly the safety instructions A proper use only guarantees a longtime and reliable operation geo FENNEL Precision by tradition SUPPLIED WITH A Rotating Laser Level FL 245HV Receiver with clamp for levelling staff Remote control Rechargeable battery Charger Wall mount Floor support Box for alkaline batteries Laser intensive glasses Magnetic target Container User manual FL 245HV with receiver FR 45 A...

Страница 3: ... 9 Y axis 5 9 Axis direction vertical yes Remote control range IR 100 m Rotating speed 300 800 rpm Power supply operating time 26 h NiMH Temperature range 20 C 50 C Dust water protection IP 65 CHARACTERISTICS Working range up to 1200 m diameter depending on the receiver used Dust water protection IP 65 for exterior application Variable scanning and laser point mode Permanent 90 plumb beam Automati...

Страница 4: ...is being charged if the LED is green the battery is fully charged ATTENTION The rechargeable battery can be charged if it is in the instrument or if it is ouside Battery status indication If the ON OFF LED flashes the battery has to be recharged Both the standard Li Ion battery pack and alkaline batteries can be used 1 Insert alkaline batteries into the alkaline battery box ensure correct polarity...

Страница 5: ... set up outside of its self levelling range In this case set up the instrument on a more even surface VERTICAL USE Unfold the datum point on the integrated floor mount and set up the laser in its vertical lay down position The laser automatically self levels in this position Set the ciruclar bubble as accurately as possible by using the two thumb screws This ensures that the instrument is set with...

Страница 6: ...TTON ONLY 4 With this button the remote control function can be disabled in order to avoid that several units on one construction site disturb each other If the remote control LED is illuminated it is the remote control function is ready to receive LED REMOTE CONTROL 9 If the LED is illuminated the the remote control function is ready to receive TILT MODE 7 After completion of the self levelling p...

Страница 7: ...m the rotation to the scan mode Press button 1 x long scan line Press button 2 x short scan line Press button 3 x dot mode SCAN DIRECTION 13 Change the direction of the scan mode with button 13 LED 14 REMOTE CONTROL This LED flashes if any button is used and a beep sounds ON OFF REMOTE CONTROL FUNCTION 15 With this button the remote control can be powered off but not the instrument Press the ON OF...

Страница 8: ...28 EN APPLICATION ...

Страница 9: ...racy coarse normal fine 10 Light on off 11 Magnets 2 12 1 4 thread for clamp back side SUPPLIED WITH Receiver FR 45 battery clamp user manual Technical Data Indication Front display Accuracy coarse 10 mm Accuracy normal 4 mm Accuracy fine 2 mm Tones 3 Operating time 400h Power supply 1 x 9V SYMBOLS 1 Power ON OFF 2 Battery status indicator 3 Detection indicator 4 Sound ON OFF 5 Detected position i...

Страница 10: ...rder to save battery power the receiver will automatically turn off if it has not received laser scan ning singal for 5 minutes USE OF RECEIVER Press the button 5 to switch the unit on Move the receiver up and down carefully to detect the laser beam A Move the receiver down Acoustic signal ultra short requent beep B Move the receiver up Acoustic signal short requent beep C On level Acoustic signal...

Страница 11: ...y front rear LED height indicators front side rear Power supply Operating times Alkaline 110 h Temperature range 10 C to 50 C Display illumination yes Magnets top side Bubble vials top side Dust water protection IP 67 Dimensions 170 x 77 x 32 mm Weight 0 5 kg FEATURES Extra long receiving window mm indication of height difference between the laser plane and the reference point The segments of the ...

Страница 12: ...ear LCD Display Magnetic strip Side LED indicators Rear LED indicatiors Battery compartment cover Magnetic strip LED indicators Sound illumination ON OFF button Accuracy button Bubble vial Bubble vial Receiving window 0SET button Offset Front LCD Display Units Power ON OFF FEATURES ...

Страница 13: ...l indication 0SET symbol Accuracy symbol Illumination symbol Sound symbol ON OFF button Power ON OFF the receiver Accuracy button Select accuracy setting UNITS button Select units of measure Sound illumination button Sound and or illumination ON OFF 0SET button Set a relative ZERO position ...

Страница 14: ...tment cover Always remove the batteries if the receiver will not be used for a long period of time to avoid leakage BATTERY STATUS INDICATOR The FR 77 MM front LCD display has four power status symbols The receiver will automatically power off when the batteries are empty AUTOMATIC POWER OFF If the receiver does not receive a laser beam or is not operated for 10 minutes it will automatically power...

Страница 15: ...ram right SELECT ACCURACY SETTING Power on the unit and select the receiving accuracy fine normal or coarse by pressing the accuracy button The default accuracy setting following Power is Fine SWITCH ON OFF THE SOUND Power on the receiver and press the button Sound illumination to select the sound and volume required The symbols in the LCD display show the status of the sound and volume coarse 9 m...

Страница 16: ... receiver and keep the button Sound illumination pressed until the illumination is on SELECT THE UNITS Power on the receiver and press the UNITS button sucessively until the required unit symbol appears in the display Millimetre Centimetre Inch Inch fraction ...

Страница 17: ...ance between the rotating laser and the receiver is less than 1 m erroneous measurements may occur Indication 1 The laser beam is high arrow is illuminated Acoustic signal Slow beep Move the receiver up Indication 2 The laser beam is low arrow is illuminated Acoustic signal Fast beep Move the receiver down Indication 3 The LED 0 position bar is illuminated Acoustic signal Continuous beep On level ...

Страница 18: ...ser beam is now set as the relative 0 position on the receiver Press the 0SET button to return to the default mode MM INDICATION If the reference level of the receiver is e g 18 mm below the laser beam this height difference will be displayed by an exact numerical value see the left diagram further examples The laser beam is exactly on level The laser beam is 19 mm above the reference point move t...

Страница 19: ...with a laser pole levelling staff or similar accessory For optimum accuracy always level the bubble vials on the receiver before taking measurements SPECIAL MOUNT To increase the versatility and scope of the receiver a special mount is provided see illustrations ...

Страница 20: ...or either parts or labour In case of a defect please contact the dealer where you originally purchased this product The warranty will not apply to this product if it has been misused abused or altered Without limiting the foregoing leakage of the battery bending or dropping the unit are presumed to be defects resulting from misuse or abuse EXCEPTIONS FROM RESPONSIBILITY 1 The user of this product ...

Страница 21: ...should be carried out by authorized workshops only Please contact your local dealer Do not remove warning labels or safety instructions Keep the instrument away from children Do not use the instrument in explosive environment The user manual must always be kept with the instrument LASER CLASSIFICATION The instrument is a laser class 2 laser product according to DIN IEC 60825 1 2014 It is allowed t...

Страница 22: ...5 Baunatal Tel 49 561 49 21 45 Fax 49 561 49 72 34 info geo fennel de www geo fennel de Technische Änderungen vorbehalten All instruments subject to technical changes Sous réserve de modifications techniques Precision by tradition 10 2019 ...

Отзывы: