2. Before Installation /    

 

 

  Starting up

Delieverance

Heat pump with build in controller

Installation manual with technical data

Operating instructions

Electrical heating element 1,5 kW

2.1 Important safety instructions

In the design and implementation of the Vanvex RS, all 

relevant EU guide lines have been adhered to.

Work on the Vanvex RS may only be performed 

by trained personnel! Take all necessary 

precautions in order to avoid accidents while 

working!

2.1.1 Cooling system – safety instructions 

The trained repairman must see to it that parts containing 

the refrigerant are emptied to a level at which the execution 

of the work can occur in a responsible manner without any 

dangers, before the commencement of repairs and service 

work.

When repairing and servicing the Vanvex RS with the 

refrigerant system opened, and particularly for work with an 

open flame (soldering, welding, etc.), precautions must be 

taken to prevent fires from starting.

2.1.2 Electrical circuit – safety instructions

When working on the Vanvex RS, the main 

supply must always be disconnected – pull the 

plug out!

When connecting the Vanvex RS to the power supply, the 

local and national rules and norms must be adhered to.

In addition, regard must be paid to possible requirements 

posed by the energy supplier.

2.1.3 Water circuit – safety instructions

Only drinking water quality water may be used. During 

installation, regard must be paid to the choice of materials 

and it must be ensured that they can work together without 

problems in the entire circuit. 

Special attention must be paid when using 

galvanised components and components 

containing aluminium!

Safety equipment must be installed to prevent over pressure 

in the system.

All pipe work must comply with water safety regulations.

2.2 Delivery

The Vanvex RS is delivered without water, condense water 

tube and the safety equipment for the water circuit.

2.3 Storage

The Vanvex RS must be stored upright without water and 

in its packaging.

2.4 Transport

The Vanvex RS can not be tilted up to more than 45°C. If 

this limit is exceeded, the Vanvex RS can be defect.

The Vanvex RS’s top / casing is not suitable for lifting with 

and must be carefully avoided during transport.

2.4.1 Transport with forklift

For transport with a forklift, the Vanvex RS must stand on 

the associated transport frame. Always lift it slowly. Due 

to the high position of the centre of gravity, the Vanvex R 

must be secured against tipping during transportation.

2.4.2 Unloading the heat pump

In order to avoid damages, the Vanvex RS must be 

unloaded on a flat surface.

2.4.3 Transport with trolley

The Vanvex RS may only be transported on an associated 

transport frame. Also when transported on stair cases. The 

transportframe measures appr. 70x80 cm incl. packaging.

The Vanvex R must be secured against sliding on the 

trolley.

The Vanvex RS must be secured against sliding on the 

trolley.

Water connections, etc., may not be used for transportation 

purposes.

Make sure that the trolley does not damage the cabinet 

and the connections.

2.5 Placement /set-up

The Vanvex RS may only be installed in a frost-free room.

The installation location should comply with the following 

criteria:

•  Room temperature between 0 and +35°C.

•  Drain possibility for condensate water.

•  No abnormal dust concentration in the air.

•  Solid base (approx. 1140 kg / m²)

•  To achieve problem-free functioning and to allow 

access for service, it is recommended that 0.5 m 

free space be maintained around the unit.

Set-up sequence:

1.  Remove the packaging from the pallet.

2.  Remove the transport fittings from the pallet.

3.  Take the Vanvex RS off the pallet and place it at 

the desired location.

4.  Adjust the Vanvex RS vertically by adjusting the 

feet.

2.6 Connection of water pipes

During installation the actual pressure and pressure losses 

must be taken into account regarding pipe dimensions to 

assure sufficient pressure and water flow rates.

Installation Manual

Содержание Vanvex R OPTIMA 155

Страница 1: ...Installation Manual Vanvex RS Domestic hot water heat pump Version V1 1008 GB...

Страница 2: ...it safety instructions 8 2 2 Delivery 8 2 3 Storage 8 2 4 Transport 8 2 4 1 Transport with forklift 8 2 4 2 Unloading the heat pump 8 2 4 3 Transport with trolley 8 2 5 Placement set up 8 2 6 Connecti...

Страница 3: ...emperature with the heat pump on C 55 Max water temperature with operation of heat pump and electrical heating element C 65 Domestic water boiler Material Steel specially enamelled Net volume Litre 28...

Страница 4: ...nt overview No Description 1 Compressor 2 Condenser 3 Vaporiser 4 Centrifugal fan 5 Expansion valve 6 Drying filter 7 Pressure switc 8 Magnitic valve 9 One way valve Component overview Sensor Temperat...

Страница 5: ...the heat pump have to have a safty valve and an automatic nonreturn valve The installation of the cold water connection shall be at the back of the unit 3 4 RG The max pressure is 10 bar and the max t...

Страница 6: ...2 Reducing valve 3 Test valve 4 Contra valve 5 Manometer adapter 6 Circulation pump 7 Screwed connection with coupling 8 RG Connecting of cold water according to DIN 1988 Safety valve p 6 bar to be mo...

Страница 7: ...PE MA4 T8 T7 T6 T5 PE N 13 12 11PE 10N 9F 8 6 5 4 3 2 1 X1 X3 X2 T1 6AH ICD 852xxx155 PC COM PE L PE Brun brown braun Bl blue blau Brun brown braun Sort black schwarz Brun brown braun Bl blue blau Gu...

Страница 8: ...the safety equipment for the water circuit 2 3 Storage The Vanvex RS must be stored upright without water and in its packaging 2 4 Transport The Vanvex RS can not be tilted up to more than 45 C If thi...

Страница 9: ...be equipped with a pressure reduction valve and eventually a filter When installing the pipe work in the house any dirt in the pipes must be avoided Eventually flush the pipes with clean water before...

Страница 10: ...ood beneath 5 Carry on with removal c Remove the lower part of the palette while keeping the product in an angle position still with 2 pcs wood be neath 6 Product on floor with 2 pcs of wood 7 Removal...

Страница 11: ...ain The water trap must contain a water column of at least 60 mm It is also possible to use other tight air traps like a tube with one turn If mounting of the water trap is omitted water damage or dam...

Страница 12: ...fer to user manual 5 Fault finding The domestic hot water heat pump is equipped with followring safety devices 5 1 High pressure switch To prevent the compressor exceeding its range of application the...

Страница 13: ...The right to make changs is reserved 13 6 Service Maintenance For maintenance refer to the operating instructions...

Страница 14: ...The right to make changs is reserved 14 Note...

Страница 15: ...The right to make changs is reserved 15...

Страница 16: ...erslev Tel 45 73 53 27 00 Fax 45 73 53 27 07 E Mail salg genvex dk Germany Novelan GmbH D 95359 Kasendorf Tel 49 0 92 28 99 60 7 0 Fax 49 0 92 28 99 60 7 189 E Mail info novelan de Great Britain Total...

Отзывы: