8
- Technishce Änderungen vorbehalten -
2. Before Installation /
Starting up
Delieverance
Heat pump with build in controller
Installation manual with technical data
Operating instructions
Electrical heating element 1,5 kW
2.1 Important safety instructions
In the design and implementation of the Vanvex RS, all
relevant EU guide lines have been adhered to.
Work on the Vanvex RS may only be performed
by trained personnel! Take all necessary
precautions in order to avoid accidents while
working!
2.1.1 Cooling system – safety instructions
The trained repairman must see to it that parts containing
the refrigerant are emptied to a level at which the execution
of the work can occur in a responsible manner without any
dangers, before the commencement of repairs and service
work.
When repairing and servicing the Vanvex RS with the
refrigerant system opened, and particularly for work with an
open flame (soldering, welding, etc.), precautions must be
taken to prevent fires from starting.
2.1.2 Electrical circuit – safety instructions
When working on the Vanvex RS, the main
supply must always be disconnected – pull the
plug out!
When connecting the Vanvex RS to the power supply, the
local and national rules and norms must be adhered to.
In addition, regard must be paid to possible requirements
posed by the energy supplier.
2.1.3 Water circuit – safety instructions
Only drinking water quality water may be used. During
installation, regard must be paid to the choice of materials
and it must be ensured that they can work together without
problems in the entire circuit.
Special attention must be paid when using
galvanised components and components
containing aluminium!
Safety equipment must be installed to prevent over pressure
in the system.
All pipe work must comply with water safety regulations.
2.2 Delivery
The Vanvex RS is delivered without water, condense water
tube and the safety equipment for the water circuit.
2.3 Storage
The Vanvex RS must be stored upright without water and
in its packaging.
2.4 Transport
The Vanvex RS can not be tilted up to more than 45°C. If
this limit is exceeded, the Vanvex RS can be defect.
The Vanvex RS’s top / casing is not suitable for lifting with
and must be carefully avoided during transport.
2.4.1 Transport with forklift
For transport with a forklift, the Vanvex RS must stand on
the associated transport frame. Always lift it slowly. Due
to the high position of the centre of gravity, the Vanvex R
must be secured against tipping during transportation.
2.4.2 Unloading the heat pump
In order to avoid damages, the Vanvex RS must be
unloaded on a flat surface.
2.4.3 Transport with trolley
The Vanvex RS may only be transported on an associated
transport frame. Also when transported on stair cases. The
transportframe measures appr. 70x80 cm incl. packaging.
The Vanvex R must be secured against sliding on the
trolley.
The Vanvex RS must be secured against sliding on the
trolley.
Water connections, etc., may not be used for transportation
purposes.
Make sure that the trolley does not damage the cabinet
and the connections.
2.5 Placement /set-up
The Vanvex RS may only be installed in a frost-free room.
The installation location should comply with the following
criteria:
• Room temperature between 0 and +35°C.
• Drain possibility for condensate water.
• No abnormal dust concentration in the air.
• Solid base (approx. 1140 kg / m²)
• To achieve problem-free functioning and to allow
access for service, it is recommended that 0.5 m
free space be maintained around the unit.
Set-up sequence:
1. Remove the packaging from the pallet.
2. Remove the transport fittings from the pallet.
3. Take the Vanvex RS off the pallet and place it at
the desired location.
4. Adjust the Vanvex RS vertically by adjusting the
feet.
2.6 Connection of water pipes
During installation the actual pressure and pressure losses
must be taken into account regarding pipe dimensions to
assure sufficient pressure and water flow rates.
Installation Manual