background image

9

Subject to Technical Modifications of Combi 185 S/LS

Heat-exchanger operation

 

(S-model only)

1) Hot boiler

Heat exchanger operation is used if it is desired to heat 

water only via an external hot boiler (an oil burning fur-

nace for example). The unit is set to the lowest acceptable 

water temperature and will then function as an emergency 

back-up. Thereafter, it will be the thermostat on the oil 

burner which will determine the heating of the water. 

In this operational mode an extra sensor is mounted in the 

tank in order to control the boiler. See the section: Optional 

connection of a heat-exchanger. 

Maximum water temperature must be set at 65 °C. 

This can be exceeded for short periods, in connection with 

disinfection for example.

If the boiler must function as an extra heat source for 

the unit, it is recommended that the temperature of the 

thermostat of the boiler is set about 5 °C lower than the 

thermostat of the unit itself.

This will secure that the boiler is only operating when wa-

ter consumption cannot be fulfilled by the unit.

When the unit is made operational, it is necessary to en-

sure that sensor values are set as desired. 

2) Wood burner or solar cells

This optional operational connection can be utilized if 

a wood burning furnace or a solar cell installation is to 

support the function of the unit. Via sensor T9 (see the 

diagram), the temperature in the wood burning furnace or 

the solar cell installation is measured.  If the temperature 

is higher than the water temperature in the tank, it is pos-

sible for the control unit to activate an accelerator pump 

which will circulate water through the spiral in the tank, 

and thereby heat the water.  Hysteresis can be adjusted to 

0-5 °C. Maximum temperature is 70 °C. Above this level, 

the control unit will disengage the pump in order to protect 

the tank. 

Energy saving tips 

Do not set the water temperature higher than necessary.

The lower the temperature, the higher the efficiency of the 

unit. Only use high temperatures when necessary. 

Tips for operating the  

fans 

Do not ventilate more than necessary. Over-ventilation will 

often result in very low humidity in the atmosphere in the 

dwelling which will result in discomfort. In addition, it is a 

waste of energy to over-ventilate.

However, always be aware of the required minimum at-

mospheric volume and that this is adhered to.

Re-checking

After the installation has been completed, it is recom-

mended to check once again that all connections are 

water- and airtight and that condensed water will flow off 

without hindrance. 

For maintenance, see the instruction manual. 

For trouble -shooting, see the instruction manual.

Содержание Combi 185 LS

Страница 1: ...erigesvej 6 DK 6100 Haderslev Tel 45 73 53 27 00 salg genvex dk genvex dk COMBI 185 S LS VENTILATION HEAT PUMP AND SANITARY HOT WATER WITH ELECTRIC DIAGRAM FOR OPTIMA 311 UK Version 02 07 2014 INSTALL...

Страница 2: ...ducts in heated spaces 7 Water connection 7 Electrical water heater sensor anode 7 Electrical installation 7 Check and initial adjustment of the system 8 Optimal initial adjustment of the system 8 Re...

Страница 3: ...185 uses only about 30 of the electric energy which a directly heated tank would consume Coolant Circulation Coolant circulation takes place within a self contained circuit where the HFCKW free coolan...

Страница 4: ...fficient pressure and water where this is drawn Those aspects of the installati on which concern water must be performed in accordance with local HWS regulations Water pipes can either be made hard or...

Страница 5: ...is to be connected to the various connectors Fresh air FRONT Exhaust air Supply air Extract air Connect air Supply air The ducting system leading from the unit to air injected into the living quarter...

Страница 6: ...lation of ducts in cold spaces In order to exploit the unit s high recovery potential efficiency it is necessary to insulate the ducts correctly Genvex recommends as follows Supply air and extract air...

Страница 7: ...fitting the piping system in a dwelling contami nation of the pipes must be avoided If required flush the piping system with clean water before the unit is connected When fitting pipes it must be ens...

Страница 8: ...can be put into opera tion The system should be adjusted initially for basic ventila tion which is speed 2 In order to reduce energy consump tion as much as possible the overall atmospheric volume sho...

Страница 9: ...be utilized if a wood burning furnace or a solar cell installation is to support the function of the unit Via sensor T9 see the diagram the temperature in the wood burning furnace or the solar cell i...

Страница 10: ...10 Subject to Technical Modifications of Combi 185 S LS Electric diagram Optima 311 with ES 960 PCB...

Страница 11: ...11 Subject to Technical Modifications of Combi 185 S LS PCB ES 960 for Optima 311...

Страница 12: ...heat exchanger MA2 Supply air T4 T5 T3 T6 T1 T7 T8 Hot water container Heat coil KV VV T9 Solar collector T2 Controller panel Extract air Fresh air MA4 Sensors T1 Supply air T2 Room T3 Fresh air T4 E...

Страница 13: ...maximum tempera ture of the sanitary hot water does not transgress 65 C and the pressure in the accessory heat exchanger is not more than 3 bar Boiler Heater circuit Heat pumo Sensor lead 1 Non return...

Страница 14: ...14 Subject to Technical Modifications of Combi 185 S LS...

Страница 15: ...Genvex A S Sverigesvej 6 DK 6100 Haderslev Tel 45 73 53 27 00 salg genvex dk genvex dk...

Отзывы: