background image

3500W Propane Generator   

General Precautions (cont’d)

Personal Safety (cont’d)

 • Avoid accidental starting. Make sure the power switch is in its “OFF” position, and disconnect  
   the spark plug wire when not in use.

 • Remove adjusting keys or wrenches before turning the generator on. A wrench or a key that is  
    left attached to a rotating part of the generator may result in personal injury. 

 • Do not overreach. Keep proper footing and balance at all times.

 • Use safety equipment. Always wear eye protection. Wear ANSI approved safety impact eye  
    goggles. Dust mask, non-skid safety shoes, hard hat, or hearing protection must be used for  
    appropriate conditions. 

 • Do not force the generator. Use the correct generator for your application. The correct generator  
    will do the job better and safer at the rate for which it is designed.

 • Do not use the generator if the power switch does not turn it on or off. Any generator that cannot  
    be controlled with the power switch is dangerous and must be replaced.

Generator Use and Care

Make sure the power switch is in its “OFF” position and disconnect the spark plug wire before 
making any adjustment, changing accessories, or storing the generator. Such preventive safety 
measures reduce the risk of starting the generator accidentally.

Store idle generators out of reach of children and other untrained persons. Generators are 
dangerous in the hands of untrained users.

Maintain generators with care. Do not use damaged generator. Tag damaged generators “Do not 
use” until repaired.

Check for misalignment or binding of moving parts, breakage of parts, and any other condition that 
may affect the generator’s operation. If damaged, have the generator serviced before using. Many 
accidents are caused by poorly maintained generators.

Use only accessories that are recommended by the manufacturer for your model. Accessories that 
may be suitable for one generator may become hazardous when used on another generator.

10

Содержание PROPANE GENERATOR

Страница 1: ...3500W PROPANE GENERATOR Owner s Manual 4 3 12 1 0 1 04 2 0 230 2 12 0 1 2 0 Please read and save these instructions www GentronUSA com...

Страница 2: ...ther partly enclosed areas Deadly levels of carbon monoxide can build up in these areas Using a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outdoors and far...

Страница 3: ...nance 23 Installation 24 Compliance 26 Specifications 27 WARNING READ AND UNDERSTAND ALL SAFETY PRECAUTIONS IN THIS MANUAL BEFORE OPERATING FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS MANUAL COULD RES...

Страница 4: ...d business hours at the service center location and the availibility of replacement parts All decisions of Gentron with regard to this limited warranty shall be final This warranty gives you specific...

Страница 5: ...equired oil adjustments or other installation and start up costs Expendable parts or accessories supplied with the product which are expected to become inoperative or unusable after a reasonable perio...

Страница 6: ...ons Be sure to retain them for future use WARNING WARNINGS INDICATE A CERTAINTY OR STRONG POSSIBILITY OF PERSONAL INJURY OR DEATH IF INSTRUCTIONS ARE NOT FOLLOWED CAUTION CAUTIONS INDICATE A POSSIBILI...

Страница 7: ...PROPANE IS EXTREMELY FLAMMABLE AND IS EXPLOSIVE UNDER CERTAIN CONDITIONS KEEP OUT OF REACH OF CHILDREN Propane fuel and fumes are flammable and potentially explosive Use proper fuel storage and handli...

Страница 8: ...hot engine shutdown If this occurs open exhaust system drain plugs if equipped and allow the gases to dissipate before attempting to restart the generator Use only engine manufacturer recommended fue...

Страница 9: ...olarized plug where one blade is wider than the other This plug fits in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a...

Страница 10: ...e electrical characteristics and rated capacities of the generator Before servicing equipment powered by the generator disconnect the equipment from its power input Keep all electrical equipment clean...

Страница 11: ...turn it on or off Any generator that cannot be controlled with the power switch is dangerous and must be replaced Generator Use and Care Make sure the power switch is in its OFF position and disconnec...

Страница 12: ...enance instructions may create a risk of electric shock or injury Heart Pacemakers WARNING PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR PHYSICIAN S BEFORE USING THIS PRODUCT ELECTROMAGNETIC FIELDS IN C...

Страница 13: ...ngth of the generator frame at its low side For trailer installation the generator should be mounted on the center point of the trailer over the wheels The trailer must be capable of supporting the we...

Страница 14: ...safety eye goggles and safety hat Do not alter or adjust any part of the generator that is assembled and supplied by the manufacturer Always follow and complete scheduled engine and generator maintena...

Страница 15: ...e to use only UL approved cords having the correct gauge and length according to the following table Nameplate Amps Cord Lengths full load 0 5 16 16 12 12 5 1 8 16 14 10 8 1 12 14 12 12 1 15 12 10 15...

Страница 16: ...Owner s Manual 15 Battery This product does not need a battery...

Страница 17: ...e connection Propane Intake Valve Step 1 Step 2 Insert hose connection to generator and tighten Insert other end of hose to the propane cylinder tighten Propane Cylinder NOTE This is your common propa...

Страница 18: ...LED WITH OIL OF A HIGH QUALITY SAE 10W 30 GRADE ENGINE OIL TO DO SO UNSCREW AND REMOVE THE ENGINE S OIL DIPSTICK LOCATED AT THE BOTTOM OF THE ENGINE CRANKCASE FILL THE ENGINE S CRANKCASE UNTIL THE OIL...

Страница 19: ...from the bottle to the machine Turn the engine switch to the ON position Move the choke lever to the START position Turn the fuel valve to the START position Turn the valve on the propane bottle all t...

Страница 20: ...19 Operation cont d 1N LNCHA HMNLO NCIHM Pull the recoil starter to start the engine Move the choke lever to the RUN position Turn the fuel valve to the RUN position Owner s Manual...

Страница 21: ...VED LINE CONDITIONER MAY CAUSE DAMAGE TO THE EQUIPMENT GENTRON IS NOT RESPONSIBLE FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN APPROVED LINE CONDITIONER 2 Once the generator is runnin...

Страница 22: ...connection to a separate generator 2 Connect the power cord of a 12 VDC powered tool or equipment to the DC Terminals CAUTION MAKE SURE TO CONNECT THE POSITIVE LEAD OF THE POWER CORD TO THE POSITIVE...

Страница 23: ...the insulator is cracked or chipped Clean the spark plug with a wire brush if it is to be reused 4 Measure the plug gap with a feeler gauge 5 Check that the spark plug washer is in good condition 6 Af...

Страница 24: ...ion If an engine problem occurs have it checked by a qualified service technition before further use Do not use damaged equipment Before each use make sure the engine s oil and fuel levels are adequat...

Страница 25: ...UIPMENT WHEN MOVING IT TO THE INSTALLATION LOCATION ALWAYS CONNECT HOIST LINES TO THE FRAME OF THE GENERATOR General Location Make sure to locate and install the generator outdoors where cooling air i...

Страница 26: ...g 3 8 diameter expansion anchor bolts not supplied Grounding NOTE IT IS RECOMMENDED THAT ONLY A TRAINED AND LICENSED ELECTRICIAN PERFORM THIS PROCEDURE Owner s Manual Brass Rod electrode Ground Connec...

Страница 27: ...cate This certificate of conformity does not cover small non road engines imported prior to the effective date of the certificate This certificate of conformity is conditional upon compliance of said...

Страница 28: ...AC 25 23A 60Hz Continuous rated Wattage 2 800 Peak Wattage 3 500 Outlet 2 120V AC 2 spring grounded One 120 240V AC twist lock outlet 27 Specifications AC electrical DC electrical 12V 8 3 A Gasoline e...