GenTran Silent Generator Скачать руководство пользователя страница 1

 

INSTALLATION and OPERATING MANUAL 

 

 

The Silent Generator™ Power System is a battery-powered backup system for 
use when backup power is required and a traditional combustion-engine 
generator power source is not practical or possible due to noise, regulation, 
reliability, space or fuel storage/availability issues.  The Silent Generator™ 
Power System provides an uninterruptible power output, ideal for office 
computers and servers, refrigeration, medical equipment, aquariums and 
other reliability-demanding power applications. When connected to AC 
power, the Silent Generator™ Power System is constantly recharging, ready 
for the next power disruption. 

 

Additionally, the Silent Generator™ Power System can be recharged with 
most any renewable DC power source such as solar, wind or hydro and 
qualifies for up to a 30% Federal Section 1122 tax credit

1

 or a Section 1603 

grant in lieu of Renewable Energy Tax Credits

2

, significantly reducing the 

initial investment required. 

 

This Installation and Operating Guide provides information required for 
proper installation, operation, environmental consideration, and battery 
maintenance recommendations. 

 

 

This manual is published for informational purposes and should not be considered all inclusive.  If further information is required, you should 
consult Gen/Tran Corporation.  Sale of product shown in this document is subject to terms and conditions outlined in appropriate Gen/Tran 
selling policies or other contractual agreement between the parties.  This document is not intended to and does not enlarge or add to any 
such contract.  Every effort has been made to ensure the accuracy and completeness of the information in this manual. Gen/Tran reserves the 
right to change and update the manual and product at any time without prior notice.  
 
No warranties, expressed or implied, including warranties of fitness for a particular purpose or merchantability, or warranties arising from 
course of dealing or usage of trade, are made regarding the information, recommendations and descriptions contained herein.  In no event 
will Gen/Tran Corporation be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or otherwise for 
any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of 
equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against 
the purchaser or user by its  customers resulting from the use of the information, recommendations and description contained herein. 

 
 

NOTE TO INSTALLER: Please leave this manual with the customer for future reference. 

Una versión en español de este manual está disponible para descargar en nuestra página web www.gen-tran.com/support/installation 

 
MODEL NUMBER ___________________________________SERIAL NUMBER ________________________________________________________ 
 
DATE OF INSTALLATION ______________________________DEALER NAME/PHONE ___________________________________________________ 
 

Please note Model number and Serial Number here for future reference.  Serial Number may be found on back of the unit.

 

 

                                                 

1

 To be eligible for a S1122 Tax Credit, the qualified property must be used in a residential property. Please consult your tax advisor for complete 

information.  

2

 To be eligible for a S1603 Grant, the qualified property must be used in a trade or business or held for the production of income. Residential or nonbusiness 

properties are not eligible. Please consult your tax advisor for complete information.

 

Содержание Silent Generator

Страница 1: ...es the right to change and update the manual and product at any time without prior notice No warranties expressed or implied including warranties of fitness for a particular purpose or merchantability or warranties arising from course of dealing or usage of trade are made regarding the information recommendations and descriptions contained herein In no event will Gen Tran Corporation be responsibl...

Страница 2: ...ill not eliminate this risk Do not operate the Silent Generator Power System with damaged or substandard wiring if it has received a sharp blow been dropped or otherwise damaged in any way Do not disassemble the Silent Generator Power System there are no user serviceable parts inside Contact Gen Tran to obtain service Attempting to service the unit yourself may result in a risk of electrical shock...

Страница 3: ...25 C Nominal Battery Voltage 48 Volts DC DC Input Operating Range 42 64 VDC Nominal AC Output 120 240 VAC 5 at 50Hz or 60 Hz Max Output Current 17 Amps 240 VAC 33 Amps 120 VAC Max Output Surge 25 C 200 7 Sec 150 30 Sec 115 30 Min Internal Battery Type Sealed Lead Acid AGM 2 types Deep Cycle repetitive discharge charge apps Float used occasionally for backup power Available Battery Capacity 800 Amp...

Страница 4: ... all times Temperature Ambient temperature not to exceed 104 F 40 C Ventilation Minimum room size of 6 x 6 x 8 Power 20A 2 Pole 125 250VAC dedicated power circuit Cabinet physical specifications Height 48 31 122 7 cm Width 19 16 48 7 cm Depth 28 3 71 9 cm Weight Model SG 4000 X 1 X 800AH storage approximately 930 lbs 422 kg Model SG 4000 X 2 X 1000AH storage approximately 1010 lbs 458 kg 1 5 UNLOA...

Страница 5: ...Power System down the ramp until the unit is on level ground Remove shipping brackets from pallet If the Silent Generator Power System is to be permanently mounted re attach the shipping brackets in reverse order mentioned above and anchor to floor 8 In case the cabinet will need to be moved to another location retain the shipping brackets ramps to move the Silent Generator Power System again They...

Страница 6: ...let Box and power inlet on the Silent Generator Power System 2 1 2 HARDWIRING CONNECTING A more permanent installation solution is to hardwire the Silent Generator Power System directly to a dedicated 20A 125 250VAC 2 Pole circuit breaker in your load center Cut the male plug off of the RJB12410 cordset and connect to the 20A 125 250VAC 2 pole circuit breaker in your load center following all loca...

Страница 7: ...7 2 3 THE USER INTERFACE LCD SCREEN OVER LOAD Systemoverload systemshutsoff loadswillnotbepowered disconnect loads will AUTO STARTafter6seconddelay SYSTEM OVERLOAD ...

Страница 8: ...ed SECTION 5 BATTERY MAINTENANCE and REPLACEMENT The Silent Generator Power System uses VRLA AGM sealed batteries full charged and ready to use from the factory The Silent Generator Power System should be installed and connected to an AC or DC power source within 90 days of purchase While the batteries have a design life of 10 years long periods between charging self discharging more frequent char...

Страница 9: ... in 6 seconds after loads are reduced 2 Recharge batteries with AC and or DC power 3 Refer to Apollo User s Manual 4 C Power system runs shorter than expected in backup mode 1 Batteries are not fully charged 2 Batteries have been damaged due to overuse or deep discharging 3 Loads are larger than planned 1 Ensure AC and or DC power is connect to system and charge for 24 hours 2 Test batteries and r...

Страница 10: ...la President Gen Tran Corporation August 16 2011 Disclaimer This certification statement is made as of August 16 2011 and Gen Tran Corporation makes no warranty as to the qualification of the products for federal tax credits if there are changes in requirements or applicable law after such date Gen Tran Corporation is not a tax advisor Taxpayers claiming a tax credit should consult a tax professio...

Страница 11: ... application use with any fuels ultra hazardous substances or other materials not pre approved by us b use as a component part of a product expressly warranted by another manufacturer c repair alteration or modifications by other than our approved service technicians d your failure to follow routine specified or suggested maintenance e removal of any tamper proof seals on the Product or f use of b...

Страница 12: ... 30009 Toll Free 1 888 GEN TRAN www gen tran com PN 50772 Rev A Gen Tran and PowerStay are registered trademarks of Gen Tran Corporation Silent Generator is a trademark of Gen Tran Corporation 2011 All rights reserved ...