TECHNICAL SUPPORT:
1.800.283.5936 (USA) OR 1.801.974.3760
APPENDICES •
WORKSHEETS
61
Input Channel
123456789
1
0
11
1
2
Program Parameter
Selection Range
Input
T
ype
Mic 55dB
, Mic 25dB, Line
Phantom Power
On
, Of
f
Input Gain
Adjust
-60dB to +20 dB (
0
)
AGC
On,
Off
Mute
On,
Off
Input Filters 1-4
See Processing Filters Worksheets
Input
A
ctivation
Auto
, Manual
Chairman Mic
On,
Off
Gate Ratio
0 - 50 dB (
15
)
Of
f
Attenuation
0 - 50 dB (
12
)
Hold
T
ime
.1 - 8.0 seconds (
.3
)
Decay Rate
Slow
,
Medium
, Fast
Manual
Ambient
0dB to -70dB (
-30
)
Adaptive
Ambient
On
, Of
f
P
A
Adaptive Mode
On,
Off
P
A
Adapt Reference
Output 1-12,
AEC/Expansion Bus Ref E1-E4
See System Parameters to define E1-E4.
Mixer Group Select
Internal 1-4 or Global
A
-D (A)
See System Parameters to define Mixers.
Output Channel
123456789
1
0
11
1
2
Program Parameter
Selection Range
Output Gain
Adjust
-60dB to 20 dB (
0
)
Mute
On,
Off
NOM
On
or Of
f
AB
C
D
E
F
G
H
Program Parameter
Selection Range
Processing Filters 1-15
See Processing Filters Worksheets
Delay
0-500ms (
0ms
) .02ms steps
Compressor
On,
Off
Threshold
-30dB to +20dB
(0dB)
Ratio
1:1
- 1:20
Attack
T
ime
0.5ms to 100ms in 0.5ms steps
(1ms)
Release
T
ime
5ms to 2sec/Increment of 5ms
(1s)
Processing
Attenuation
0dB to -60dB
(0dB)
XAP
800 Input/Output Parameters W
orksheet
Processing Channel
Gentner XAP 800
Acoustic Echo Cancellation
On
, Of
f, adapt reference, non-linear process.
Noise Cancellation
Off
On,
, 6-15dB cancellation depth
Speech Leveler
Off
,On
AEC Reference
Output 1-12,
AEC/Expansion Bus Ref E1-E4
XAP
800
Input/Output
P
arameters
W
orksheet
Содержание XAP 800
Страница 1: ...XAP 800 White Paper ...
Страница 67: ......