TECHNICAL SUPPORT:
1.800.283.5936 (USA) OR 1.801.974.3760
APPLICATIONS •
BOARDROOM EXAMPLE
42
Note that the compressor is enabled.
Also, note that the Threshold is set to
10 dBu and the ratio is set to 1:5.
These settings will help ensure a
consistent maximum output level
when there are sudden changes in
input level.
The Group selector is set to Group 1
(the compressor for EQ CD Right is
also set to Group 1). All compressors
set to a particular group will operate
simultaneously. In this case, you want
the compressors for both the left and
right CD channels to operate in unison.
Close this window, then click
Filters
in
EQ CD Left to open the Processing
Filters window (see Figure 33).
In this scenario, high-shelving and low-
shelving filters are established for the
left CD channel to enhance
audio response. The same
filters would be established for
the right CD channel.
The high-shelving filter has a
frequency of 3kHz and gain of
3dB. The low-shelving filter has
a frequency of 300Hz and gain
of 3dB.
The outputs are assigned as
indicated in the matrix; no
further output configuration is
necessary for this example.
For more information about
configuring G-Ware functions,
see the XAP 800 Installation
and Operation Manual.
Figure 32. Compressor Setup Window
Figure 33. Processing Filters Window
Содержание XAP 800
Страница 1: ...XAP 800 White Paper ...