background image

TROUBLESHOOTING

This section contains the most common problems that can occur with the 
Mask Light Amplified Mic along with probable causes of malfunction and 
recommended corrective actions .

Item

Problem

Probable Cause 

Remedy

1

Mask Light will not 
turn on of off 

Loose or broken or not properly 
connected connections 

A. Ensure good 
connection, through 
proper torque of the two 
mounting screws 

B. Replace communi-
cations / power cord 
assembly

2

Momentary switch on microphone 
inoperative

Replace internal 
assembly

3

Microphone is 
intermittent 

Contacts not properly contacting 

A. Verify continuity 
of communications / 
power cord assembly 

B. Tighten screws to 
proper torque 

4

LED is intermittent 

Contacts not properly contacting 

A. Verify continuity 
of communications / 
power cord assembly 

B. Tighten screws to 
proper torque 

Table 1 – Inspection and Maintenance

Содержание MASK LIGHT AMPLIFIED MIC

Страница 1: ...1002682 00 REV A 2021 Gentex Corporation Gentex is a registered trademark of Gentex Corporation or its affiliates MASK LIGHT AMPLIFIED MIC QUICK REFERENCE GUIDE...

Страница 2: ...the external assembly such that the screws match with the two outer holes on mask NOTE Do not remove rubber cover 1 Using two fingers to hold the screws in place push the external assembly into the ma...

Страница 3: ...tom of the mask cavity when installed Align the internal assembly pins to match the inner holes in the mask 4 Press the internal assembly into place until the push pins snap together 5 Tighten the Phi...

Страница 4: ...Oxygen Mask Regulator Helmet and Communications Test Set or other microphone test equipment 7 8 Follow these steps to operate the Mask Light Amplified Mic POWER ON OFF Use tongue switch to toggle the...

Страница 5: ...te communications test set configured for 28 Volt operation Actuate the lip tongue lever switch to ensure proper on off function 1 2 3 Step Nomenclature Inspect For Repair 1 External Assembly Cuts pun...

Страница 6: ...re good connection through proper torque of the two mounting screws B Replace communi cations power cord assembly 2 Momentary switch on microphone inoperative Replace internal assembly 3 Microphone is...

Страница 7: ...for this product Part Number Description 1001682 00 Mask Light Amplified Microphone Assembly 1001682 02 External Assembly Mask Light Amplified Microphone Replacement Kit 1001682 01 Internal Assembly M...

Страница 8: ......

Отзывы: