2) Assemble Clamp parts (if required)

 

If your clamps came unassembled, please follow these simple steps.  
It is very important that the washer always be used between the 
knob and the clamp body.  
- Slide telescoping rods into clamp bodies. 
- Install set pins through clamp bodies and telescoping rods 
- Install carriage bolt through one end and seat into clamp 
- Loosely install washer and self-locking knob onto carriage bolt 

 

3) Install Clamp on Generator Frame (or Frame Adapter)

 

 

- Locate the first clamp to be installed just below the electrical panel on your generator  
- If required, slide 

rubber sleeve

 over frame member 

(1” and 1 ¼” frames only – 

adapter not for use on 1 ½” frames)

 

- Position rubber adapter opening to face outward toward clamp opening (fig. A).  
Alternatively the rubber adapter opening    can face away from the clamp opening if it is 
not possible to face it toward the opening. 
- Push clamp opening straight onto frame opening (fig. A).  The clamp will pop over the 
frame.  Then slide up and over rubber adapter (fig. B) (if used) 
- Position clamp diagonally from sides of the generator frame (fig. C); 
- Tighten knob, centered on washer until clamp is firmly in place.  This usually requires 
2-4 full turns once the knob/washer seat to the clamp body.   If the clamp is over 
tightened, the clamping strength is reduced as you will notice the clamp mouth begin to 
pull away from the frame.  In this case, slightly release the tension on the knob 
- Repeat procedure on remaining three sides; position clamps at generally the same 
height.  

 

Fig. 3-A   

 

Fig. 3-B                             Fig. 3-C

 

 
 

 

Содержание StormBracer

Страница 1: ...Manual Free Installation Tip Videos www GenTent Com Installation THANK YOU Congratulations on your purchase of the GenTent the first ever wet weather safety canopy specifically engineered for portabl...

Страница 2: ...ent Accessories and Spare Parts Catalog 16 We are happy to double check your installation at no cost and offer any additional adjustment advice or tips Simply email your pics to support gentent com in...

Страница 3: ...clamp base Tightening the knob without using the washer VOIDS the WARRANTY as it risks breakage CAUTION Over tightening clamps should be avoided If you notice the mouth of the clamp pulling aware fro...

Страница 4: ...the GenTent that have not been specified by the manufacturer GenTent products or components returned without an RMA and proof of purchase are not covered see How to Get Service Also consequential and...

Страница 5: ...lescoping rod set pins 8 GenTent clamp rubber pads for 1 and 1 5 round tubular frames If you purchased a GenTent 20K product code begins with GT20K 1 Product and Safety Manual 1 GenTent 20k Canopy 1 S...

Страница 6: ...nting point for the GenTent clamps Should your kit include a frame extender or frame adapter package GTX GTU GTR GTH please follow the instructions for installation of the frame extender s or frame ad...

Страница 7: ...on the diameter you will use one or both of these with your clamps Please see the following matrix A 1 inch B 1 25 inches C 1 5 inches Rubber Pads Yes No Yes Rubber Sleeve Yes Yes No If you do not kn...

Страница 8: ...de aligns with the height of the clamp Test fit the pad inside the clamp opening as shown Peel and Stick the pad into the clamp Peel the backing paper from the pad Take care when peeling the backing s...

Страница 9: ...frames only adapter not for use on 1 frames Position rubber adapter opening to face outward toward clamp opening fig A Alternatively the rubber adapter opening can face away from the clamp opening if...

Страница 10: ...rved V5 July 2013 4 Set Rod Adjustment Pin See Easy Adjustment Guide for GenTent 10k or GenTent 20k depending on your model below Measure length and width of generator frame to the outside of the fram...

Страница 11: ...A Fig 4 B Following the Pin Setting shown Fig 4 A and 4 B set telescoping rod to proper location and install setting pin Note that the rod location for setting 0 and 1 are the same all the way in Fig...

Страница 12: ...rresponding clamp hole Insert a fiberglass frame rod into Central Connector hole until it stops fig 5 A Insert other end of the fiberglass rod fully into the correct clamp hole of the corresponding cl...

Страница 13: ...equal and level fig 6 A Center GenTent canopy such that Vent Rod is centered under the top cap fig 6 A Fig 6 A GenTent 10k and GenTent 20k Slide one corner elastic over the corresponding clamp telesc...

Страница 14: ...short electrical skirt otherwise select the long electrical skirt Only use one skirt Flip the canopy overflap up from corner to corner on the side that is over the electrical outlets fig 6 C Align the...

Страница 15: ...y Now press the main skirt body over the electrical outlet to the other corner then wrap that edge around and press firmly in place Proper Door Sealing Tip GenTent now ships with the StormBracer door...

Страница 16: ...GenTent clamp from directly connecting to the frame or when a generator frame is small and requires extended length or width GTACCB1U00 Universal Frame Extender injection molded for use with square tu...

Отзывы: