*Regular service must be carried out on the product to avoid product failure.

Automatic ON/OFF

Wave ON/OFF

Hygienic/Flush

RUN TIME ADJUSTMENT

Before changing the run time, Select 
the Mode option with the black 
remote controller. Then, using the 

 

Grey  remote controller,  Button 3 
(increase) and Button 4 (decrease) 
the run time.

Note:

To change the time between hygiene 
flushes (6hours, 12hours, 24hours, 
48hours) Use the black remote 

controller 2 . To INCREASE the time 
between  hygiene flush use button 
3. To Decrease the time between 
hygiene flushes button 4 .

Remote Operation

When hands are in the sensor’s range, program 
turns ON. Removing hands from the sensor’s 
range will switch the sensor OFF. See Figure 1

Default is for Sensor to switch OFF after 2 
seconds RUN; however this is adjustable with 
the  Grey remote controller  1.

Waving hands within the sensors range switches 
the program to ON.

Waving hands again within the sensors range 
will switch the sensor to OFF. See Figure 2

Pre-set run time is 15 seconds run, however 
this is adjustable using the Grey remote 
controller 1.

• 

Hygiene flush is not activated by  Default.

• 

Hygiene flush can be activated by black 
remote STS9005B2.

• 

Hygiene flush run time is locked at 40 
second run time. This run time cannot be 
adjusted.

Figure 1

Figure 2

Functions

Grey Remote

Black Remote

STS9006

Adjusting 

Controller 

Set

Product 

Type

Sensor Range and Time 
Adjustment.

*Sensor Adjustment range 

<100mm up to 200mm

Selection Mode

Button 1

Increase the sensor distance 
( 1cm-2cm increments)

Activate Automatic ON/OFF 

( 2sec run time)

Button 2

Decrease the sensor distance 
( 1cm-2cm increments)

*Before using  buttons 3 or 4,  

First select the Mode (with the 

black remote  2)

Activate Wave ON/OFF  (15 sec run time)

Button3

Increase the run timing

Increase time between Hygiene flush

Button 4

Decrease the run timing

Decrease time between Hygiene flush

Button 5

Deactivate / Activate Sensor

Hygiene Flush on/off

Содержание SMARTEC STS1000

Страница 1: ...RTEC Electronic 90 Basin Tap STS1000 M B BM Electronic 45 Basin Tap STS1500 M B BM Electronic Wall Mounted Tap STS2500 M B BM Electronic Sensor Plate STS3500 STS4500 M B BM Electronic Sensor Plate Kit...

Страница 2: ...4 Technical Drawings 6 Installation Requirements 8 Unit Components 9 Remote Functions and Operations 10 General Connections 12 Taps Mounting Instructions 14 Soap Dispenser Instructions 16 Sensor Plate...

Страница 3: ...d under licence by SAI Global Certification Services Pty Limited ACN 108 716 669 SAI Global 286 Sussex Street Sydney NSW 2000 GPO Box 5420 Sydney NSW 2001 This certificate remains the property of SAI...

Страница 4: ...TAP ELECTRONIC SINGLE TEMPERATURE 45 BASIN TAP STS3000 M B BM STS4000 M B BM ELECTRONIC SINGLE TEMPERATURE SENSOR KIT WITH SPOUT ELECTRONIC SINGLE TEMPERATURE SENSOR KIT WITH SPOUT Product Range Use 3...

Страница 5: ...t on the product to avoid product failure STS2500 STS1020 STS2520 ELECTRONIC SINGLE TEMPERATURE WALL MOUNTED TAP ELECTRONIC SOAP DISPENSERS MAINS POWERED ONLY STS3500 M B BM STS4500 M B BM ELECTRONIC...

Страница 6: ...TURE BASIN TAP ELECTRONIC SINGLE TEMPERATURE 45 BASIN TAP STS2500 M B BM STS2520 ELECTRONIC SINGLE TEMPERATURE WALL MOUNTED TAP ELECTRONIC WALL MOUNTED SOAP DISPENSER Technical Drawings G1 2 G1 2 22 6...

Страница 7: ...stralia com au STS1020 STS4500 M B BM ELECTRONIC SOAP DISPENSER ELECTRONIC SINGLE TEMPERATURE SENSOR STS3500 M B BM S3000 ELECTRONIC SINGLE TEMPERATURE SENSOR SPOUT 400 100 120 44 3 31 7 43 400 100 12...

Страница 8: ...sance triggering and activate the sensor when installed out of the suggested minimum clearance See images bellow Installation MUST be by a certified plumber and adhere to AS3500 and manufacturer s rec...

Страница 9: ...Optimum 350kpa Maximum 500kpa Temperature Minimum 10 C Maximum 50 C Unit components No Description Qty 01 Tap Body 1 02 Sensor 1 03 Foam Washer 1 04 Metal Washer 1 05 Back Nut 1 06 Flexible Hose 1 07...

Страница 10: ...ant button to change the setting to Remote Functions Functions Grey Remote Black Remote STS9006 Adjusting Controller Set Product Type Sensor Range and Time Adjustment Sensor Adjustment range 100mm up...

Страница 11: ...ygiene flushes button 4 Remote Operation When hands are in the sensor s range program turns ON Removing hands from the sensor s range will switch the sensor OFF See Figure 1 Default is for Sensor to s...

Страница 12: ...y using the screws provided Ensure to have enough space between the wall and the fixing point FOR UNITS STS1000MB STS1500MB STS2500MB IMPORTANT INFORMATION Make sure to turn on the power first and the...

Страница 13: ...remove your hands out of range water should stop within 2 seconds The maximum duration of continuous flow is 1 minute The default factory set distance is 5 15cms BATTERY CHANGE 1 The indicator light...

Страница 14: ...nting Instructions 3 Place the Flange and the tap unit in the pre punched hole 30mm to 35mm in the counter top 4 From underneath the sink or basin fix rubber seal fixing plate and fixing nut with a sp...

Страница 15: ...able followed by the flexi hose through the tap hole Finally insert the tap body 5 Replace washer and mounting nut and fasten to the hob 6 Replace G1 2 Nut to flexi hose 7 Attach flexi hose to water m...

Страница 16: ...ing diagram for the pump installation FOR THE BENCH MOUNTED UNIT 1 Drill a hole 32mm in the counter top 2 Remove the locknut and Insert the sensor cable followed by the flexi tube through the tap hole...

Страница 17: ...wall and tighten Do not compress or distort the bracket 2 Connect the sensor cable from the sensor plate 2 to the solenoid wire Use a conduit to feed the wire up to the sensor plate 3 Install the sens...

Страница 18: ...tery power transformer Before Installation Before connecting water to the valve ensure to flush the line and remove all debris All fixtures must be installed using slim compression fittings Working pr...

Страница 19: ...r plate by tightening the screws provided equally Fix the top screws first to ensure the plate is straight Note the screws have up to 45mm adjustment 7 Place the cover plate 4 to the sensor plate 3 Us...

Страница 20: ...nlet marked connection Also check that the water connection turned on or running from the source should inspect the water pressure before connecting should be less than 500kPa 6 My tap is turning on e...

Страница 21: ...me 2 2 8 completed credit card authorisation in the form set out in Schedule 2 to these conditions accepting liability in accordance with clause 2 6 if the product is not faulty 2 3 The Principal will...

Страница 22: ...s under statute or general law as to merchantability description quality suitability fitness for purpose or otherwise 4 2 2 is not liable for loss of profit indirect consequential or incidental loss d...

Страница 23: ...Day or is after 5pm on a Business Day in which case that communication will be deemed to have been received at 9am on the next Business Day 5 2 3 if emailed at the local time in a place of receipt of...

Страница 24: ...MAR IM SMR03 MB 181119 info gentecaustralia com au www gentecaustralia com au Unit 6 20 28 Ricketty St Mascot Sydney NSW 2020 P 612 9319 4422 F 612 8088 7635...

Отзывы: