To adjust the timing of the cartridge, remove
the colour indicator. The grub screw may
now be adjusted to vary the run time.
•
To adjust the timing, you will need to
use the allen key provided or you need
a 1.5mm allen key to adjust the timing.
•
Turning the screw clockwise will reduce
the run time.
•
Turning the screw anti clockwise will
increase the run time
ADJUSTING CARTRIDGE TIMING (1 TO 20 SECONDS)
Time Adjustment
Timed Adjustment Range
FCC.
Description
TFT9050
Flow cup 0 - 5 +/-1 Sec
TFT9056
Flow cup 0-20 +/-5 Sec
TFT9054
Flow cup 0-40 +/-10 Sec
From 1 to 20 Seconds
Contact GENTEC before attempting to
change flow cups.
Warranty may be void if damage to internal
components or spare parts occurs during
service / maintenance.
GPure is available in a range of fixed timing
options which are installed ex-works.
Refer to the chart below:
Service inspections at regular intervals especially in high usage areas will assist in
optimising the operational life of the product.