background image

INSTALLATION 

MANUAL

GPure Taps

Single Temp Wall mounted Tap 

GPT7000

Single Temperature Bib Tap

     

GPT7500

Содержание GPT7000

Страница 1: ...INSTALLATION MANUAL GPure Taps Single Temp Wall mounted Tap GPT7000 Single Temperature Bib Tap GPT7500...

Страница 2: ...2 Contents Product Features 3 Product Range 4 Unit Components 5 Installation Instructions 6 Operation 8 Time Adjustment 9 Maintenance 10 FAQs 12 Product Warranty 14...

Страница 3: ...less steel and engineering plastic that minimizes the risk of lead contamination of the drinking water supply so that GPure can be specified with confidence for tapware and bubblers applications such...

Страница 4: ...property of Gentec Australia Pty Ltd All dimensions are in mm unless speci ed PRODUCT CODE AND DESCRIPTION MAR LD GPT01 MB 110320 133 7 58 1 191 71 5 133 7 36 5 41 41 7 6 50 22 191 A E D C 4 3 2 1 B...

Страница 5: ...www gentecaustralia com au 5 Unit Components Part No Desctiption 1 Indicator Cap 2 Screw 3 Handle 4 Cartridge 5 Body 6 Flexible Hose Flange separated in the GPT7000W...

Страница 6: ...e sink or basin Pre formed hole size must be 35mm in diameter O ring 4 From underneath the sink or basin fix rubber seal fixing plate and fixing nuts use socket set or tube spanner to clamp the mixer...

Страница 7: ...ll Units 1 Flush the water supply pipework prior to installation 2 Install the flow regulator into the body 3 Ensure the strainer is installed prior to connection 5 Select the desired colour indicator...

Страница 8: ...the installation and AS NZS3500 to ensure optimum per formance Min Continuous Flow Working Pressure 50kPa Max Continuous Flow Working Pressure 450kPa Optimum Flow Working Pressure 350Kpa Max Static Pr...

Страница 9: ...CARTRIDGE TIMING 1 TO 20 SECONDS Time Adjustment Timed Adjustment Range FCC Description TFT9050 Flow cup 0 5 1 Sec TFT9056 Flow cup 0 20 5 Sec TFT9054 Flow cup 0 40 10 Sec From 1 to 20 Seconds Contact...

Страница 10: ...damage to internal components occurs during this procedure First start by shutting off the main water supply No Description Qty 01 Indicator 1 02 Screw 1 03 Handle 1 04 Cartridge 1 05 Body 1 06 Stem...

Страница 11: ...g 10 place it back into the head valve 7 11 Place the stem 6 through the head valve 7 12 Replace the stopper 12 ensure the o Ring 11 is in place then tighten the stopper 12 Do not over tighten 13 Fit...

Страница 12: ...12 Notes Foroptimum operationallife the installation ofa PRVset to 350kPa is recommended...

Страница 13: ...he form set out in Schedule 2 to these conditions accepting liability in accordance with clause 2 6 if the product is not faulty 2 3 The Principal will on receipt of a notice in accordance with clause...

Страница 14: ...ivery 4 2 To the full extent permitted by law the Principal 4 2 1 excludes all implied warranties and conditions under statute or general law as to merchantability description quality suitability fitn...

Страница 15: ...s produced by the machine from which that fax is sent and which confirms transmission of that fax in its entirety unless that local time is not a Business Day or is after 5pm on a Business Day in whic...

Страница 16: ...info gentecaustralia com au www gentecaustralia com au Unit 6 20 28 Ricketty St Mascot Sydney NSW 2020 P 612 9319 4422 F 612 8088 7635 MAR IM GPT01 MB 231220...

Отзывы: