Entreprise certifiée ISO 13485 : 2016, NF EN ISO 13485 : 2016 
par le LNE G'MED 

 

 

 

 

 
 
You can access a few options, by doing a right-click on the graph. In the menu who shows up: 

   

Copy

, allows you to copy the graph in the clipboard. 

   

Save as...

, allows you to save the graph picture. 

    

Layout...

,  allows you to configure the graph layout during an impression. 

   

Print...

, allows you to print the graph. 

   

Show  points  values

,  allows  you  to  show  the  value  of  a  point  by  pointing  the  curve 

with the cursor.   (x,y)   a p p e a r s    ,  x   represent   the   pressure   and   y   le shifting. 

   

Cancel zooms

, allows you to cancel one by one the previous zooms. 

   

Cancel all zooms

, allows you to cancel all the previous zooms. 

   

Reset scale

, allows you to return to the default scale. 

 

5.5. Configuration tab 

 

 

The configuration tab gives access to you to the account management, of the printer and saves. 
 

5.5.1 Configuration 

 

 

 

     

Default practitioner name

:  e n t e r   here  the  name  of  the  practitioner  who  primarily  use  the 

ROTAM. 

It’s  this  name  which  is  found  in  the  tab  « Patient  record »  when  a  new  patient  is 

saved in the data. 

   

  Path of the data base

: select a ROTAM data base. 

By  default  the  data  base  is  placed  in  C:\Program  Files\ROTAM  Control\BDD\rotam.mdb.  
H o w e v e r ,  here indicating another path, 

it’s possible to work with another data base. 

     

Default ROTAM test

: allows  you to specif y th e def ault test used in the tab  

« Preparation ROTAM test » : 134, 150, 200, 250. 

   

Curves number

: allows you to configure the test numbers (99 maximum) whose curves will 

automatically appear in the graph tab « Results ». 

 
 

I

t’s mandatory to click the « validate the configuration » button to save and 

apply the new settings.

 

 
 

 
 
 
 
 
 
 

Содержание ROTAM

Страница 1: ...Instruction for use of the ROTAM DIAGNOSTIC INSTRUMENT FOR PERIPHERALS LIGAMENTS AND ANTERIOR LIGAMENTS INJURIES...

Страница 2: ...5 1 ROTAM software installation on a PC 7 5 2 First used of the software 8 5 3 Tab patient record 8 5 4 Tab preparation test ROTAM 9 5 4 1 Automatic mode 10 5 4 2 Information 10 5 4 3 Controls 11 5 4...

Страница 3: ...aments at this opposite rotation We perform measurements on the 2 inferiors members and the diagnostic of failure can be done by observing the difference between these 2 values 2 Glossary of marking s...

Страница 4: ...on sensors An USB A USB B cable 1 80m A 2m cable to connect the ROTAM to the electric power supply A 1 7m mains power cable An emergency stop button Electrodes cable Foot attachment with straps A prot...

Страница 5: ...ing the ROTAM installation can t be done by someone with reduced mobility 4 1 1 Unpacking See first instructions for use 4 1 2 Installation of the ROTAM The ROTAM must be on an examination table in or...

Страница 6: ...device using the USB cable Connect the power supply bloc to the sector tension 100 240 V 2 A 50 60 Hz When thel ROTAM device is turn on a green LED is on When all the connections are connect and that...

Страница 7: ...to the norm EN 60950 1 This software can be installed only on a computer with the explotation system WINDOWS A Insert the USB key in the computer drive B Click on Setup C The window Welcome to ROTAM W...

Страница 8: ...e software the following window shows up By default the Name and the Password a r e admin and admin It is then possible to create and delete accounts by going into the software configuration section c...

Страница 9: ...all a patient record already saved we can use the research by date or by name By date When a date is in with the drop down menu to the right of name you have the list of associated names to the date t...

Страница 10: ...Left torque left ligament resistance Right torque right ligament resistance Rotation leg rotation angle Tighten tightening force of the knee Complete the distance base foot data for positioning the p...

Страница 11: ...This module allows you to launch the ROTAM test and doing a reset of the programme after a loss of connection software 5 4 4 Connections This module allows you to connect the software to the ROTAM Whe...

Страница 12: ...ed test data The deletion is irreversible The button PDF Report allows you to generate a PDF file with the marked tests and the correspondent graph Reports can be found in My Documents PDF Genourob Ex...

Страница 13: ...to the default scale 5 5 Configuration tab The configuration tab gives access to you to the account management of the printer and saves 5 5 1 Configuration Default practitioner name e n t e r here th...

Страница 14: ...cument Footer information printed on top of the document 5 5 3 Account management Different fields of the account management part New user enter the name for the new user Password enter the password f...

Страница 15: ...1060 HPa It removed the patient s clothes legs Explain to the patient the operation of the ROTAM to avoid the patient surprise during the test during the forced rotation of the tibia relative to the f...

Страница 16: ...cup on the patella Locating the positions of the patella and the TTA and fix the patient s leg Attach the knee cup on the patella showing the trait of the patella in the center of the hole marked fro...

Страница 17: ...port and take the measurement Adjust the position of the support boot until the heel fits snugly Fix the foot in position by tightening both buckles Fix the tibia by tighten with the two straps Take t...

Страница 18: ...r settings rubric select the tested knee and clarify his status enter the support foot distance see 1 4 2 2 Tighten the knee cup and the thigh strap and launch the tests Secure the knee cup by tighten...

Страница 19: ...both legs display the curves via the Results tab In the number table select the data you would like to see for the curve and click on the small corresponding box to the left then click on Display clic...

Страница 20: ...n is situated on the front right side of the device If you need to If the patient experiences pain during the test for example press firmly on the button The test in progress will cease immediately an...

Страница 21: ...do not place your fingers around the boot to avoid pinching The ROTAM has been created for a functional time of 5 minutes maximum follow by a rest time of 15 minutes minimum Do not clean with water or...

Страница 22: ...CTRICAL EQUIPMENT It is strictly forbidden to delete BDDs databases from the GNRB software It is strongly recommended to save BDDs regularly to an external hard disk 8 TRANSPORTING THE ROTAM The ROTAM...

Страница 23: ...lectronic equipments 10 CERTIFICATIONS Manufacturing and marketing s dates Manufacturer s address GENOUROB SAS B t 60 rue Henri G ret 53000 LAVAL France First marketing s date 29 01 2019 The manufactu...

Страница 24: ...ensure that it is used in such an environment Emissions test Compliance Electromagnetic environment guidance Electromagnetic radiation disturbance Radiated emissions CISPR 11 Group 1 ROTAM uses RF ene...

Страница 25: ...Home health care environment and an environment of a professional health care facility Voltage dips short interruptions and voltage variations on power supply input lines IEC61000 4 11 0 UT for 0 5 cy...

Страница 26: ...environment of a professional health care facility Proximity fields issued by RF wireless communication devices IEC 61000 4 3 interim method 9 V m 710 MHz 745MHz 780MHz 5240MHz 5550MHz 5785 MHz 27V m...

Страница 27: ...Entreprise certifi e ISO 9001 2008 ISO 13485 2003 NF EN ISO 13485 2004 par le LNE G MED 27 05ROTAM FT02 008 B...

Отзывы: