1.6 GS2988 CD Control I/O
A switch (SW2) and a jumper (RSET_SEL) facilitate the manual configuration of the
GS2988 Cable Driver on the EB-GS2985-S evaluation board. These are described in the
tables below.
Table 1-5: SW3 Positions
Switch Position
Label
Description
HIGH (1)
LOW (0)
Default
1
GS
Gain Select
Compensation for
6dB flat attenuation
No change in gain
0
2
BP
Bypass
Bypass On
Bypass Off
0
3
CM
Common Mode Set
NOTE: CM should be
set to 1 when using
a 2.5V supply for the
Reclocker.
Output CM set to
2.1V
Output CM set to
2.9V
0
Table 1-6: MUTE Select (MUTE_SEL)
Label
Connection
Description
AUTO (default)
Auto Mute
HI
Mute On
LO
Mute Off
Table 1-7: SW2 Positions
Switch Position
Label
Description
HIGH (1)
LOW (0)
Default
1
EQ
Input trace
e
q
ualization
Input trace
e
q
ualization Off
Input trace
e
q
ualization On
1
2
DIS
Output disable
Output 1 enabled
Output 1 disabled
1