TROUBLESHOOTING

WARNING

!

TO PREVENT SERIOUS INJURY FROM EQUIPMENT FAILURE:
Do not use damaged equipment. If abnormal noise, vibration, or excess 
smoking occurs, have the problem corrected before further use.
Procedures not specifically explained in this manual must be performed 
only by a qualified technician.

1.  BEFORE EACH USE, inspect the 
general condition of the charger.  Check 
for:

• loose hardware,

• cracked or broken parts,

• damaged electrical wiring or

cable insulation, and

• any other condition that may affect its 
safe operation.

2. After Use, wipe external surfaces of the 
tool with clean cloth.

Problem

Possible Causes

Probable Solutions

Parallel Kit doesn't 
have power.

1. Device not plugged in 
properly.
2. Circuit Breaker tripped.
3. Parallel Kit needs service.

1. Turn off generator and check 
outlet connections for correct 
positioning. Restart generator.
2. Turn off and unplug Parallel 
Kit, reset Circuit Breaker, plug 
in Parallel Kit and turn on.
3. Have Parallel Kit repaired.

Overload indicator 
flashes.

Rated load capacity 
exceeded.

Lower the number of items 
plugged into the generator to 
stay within the rated capacity.

Follow all safety precautions whenever diagnosing or servicing the 
Parallel Kit.

Содержание PARALLEL KIT

Страница 1: ...ual contains important information regarding safety operation maintnance and storage of this product Before use read carefully and understand all cautions warnings instructions and product labels Failure to do so could result in serious personal injury and or property damage GENMAX PARALLEL KIT ...

Страница 2: ...lugs into outlets 10 Do not remove bend or modify any metal prongs or pins of the Parallel Kit 11 Do not use excessive force to make connections 12 Keep away from water 13 Keep Parallel Kit dry and away from wet ground and mud 14 Do not drive drag or place objects over Parallel Kit Cords 15 Do not walk on Parallel Kit Cords Set Up Precautions 1 Never use generators indoors including in garages bas...

Страница 3: ...acemaker failure Caution is necessary when near the engine s magneto or recoil starter 18 Accessories that may be suitable for one piece of equipment may become hazardous when used on another piece of equipment 19 Stay alert watch what you are doing and use common sense when operating this parallel kit Do not use while tired or under the influence of drugs alcohol or medication 20 Dress properly Do...

Страница 4: ... the manufacturer or distributor Only a qualified service technician may adjust parts that may increase or decrease governed engine speed 4 Wear safety goggles during service 5 Maintain labels and nameplates on the equipment These carry important information 6 Have the equipment serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the equip...

Страница 5: ... Amp Outlet The outlet is capable of carrying a maximum of 30 amps Reset If the inverter is overloaded the reset breaker will trip The engine will continue to run but there will be no output from the inverter Unplug the devices and reduce the load Push in the reset breaker to reset it Pilot Light The parallel box output is green on Ground Terminal The ground terminal is used to externally ground t...

Страница 6: ...properly 2 Add fuel and oil to the generators according to the instructions in the generator manual 3 Set up the Parallel Kit either on the ground or clipped to one of the two generators 4 Connection cable 1 Connect the Connectors red to the parallel outlets red on both generators and Parallel Kit 2 Connect the Connectors black to the parallel outlets black on both generators and Parallel Kit 3 Co...

Страница 7: ...an be restarted to avoid generator damage Do not overload the generators Substantial overloading will shut off the AC output and may shorten the service life of the generators LOW IDLE ON OFF 50A Note The voltage of the parallel device is 120V and the output current is 80A a 50A socket and a 30A socket Three generators can be connected in parallel at the same time and the total power in parallel s...

Страница 8: ... may affect its safe operation 2 After Use wipe external surfaces of the tool with clean cloth Problem Possible Causes Probable Solutions Parallel Kit doesn t have power 1 Device not plugged in properly 2 Circuit Breaker tripped 3 Parallel Kit needs service 1 Turn off generator and check outlet connections for correct positioning Restart generator 2 Turn off and unplug Parallel Kit reset Circuit B...

Отзывы: