background image

GE-R4 WIRING DIAGRAM 

GE-R4 

Section A-3

Wiring Diagram 

 

WIRING DIAGRAM GE-R4

WIRING DIAGRAM

Yanick Alain

GE-R4

13/04/07

DRAW

CONFIGURATION

WIR

/DIAGIC/GE-R4

FILE

REV

0

1265 A

GE-R4

3

2

L1

L2/N

OUTPUT

COIL

SIGNAL

1

POWER

INPUT

STAGE 1

L1

L2/N

OUTPUT

COIL

SIGNAL

3

POWER

INPUT

STAGE 3

L1

L2/N

OUTPUT

COIL

SIGNAL

4

POWER

INPUT

STAGE 4

L1

L2/N

OUTPUT

COIL

SIGNAL

2

POWER

INPUT

STAGE 2

NEUTRAL

FOR COILS

L2

L1

L2

L1

L2

L1

L2

L1

N

MASTER CONTROLLER 

OUT 1

L1

OUT 2

L1

OUT 3

L1

OUT 4

L1

3

2

3

2

3

2

 

 

www.monitrol.com

Содержание GE-R4

Страница 1: ...GE R4 MANUAL 1 2 3 4 Installation User s Guide ATTENTION ELECTRICIAN SEE WIRING DETAILS ON PAGES A 3 ADDITIONAL INFORMATION IN SECTION B WIRING DIAGRAM INDEX WARRANTY INSTALLATION www monitrol com...

Страница 2: ...orms or power supply equipment may damage this equipment For added security against line voltage surges it is recommended that surge and noise suppression devices be installed at the electrical distri...

Страница 3: ...4 FILE REV 0 1265 A GE R4 3 2 L1 L2 N OUTPUT COIL SIGNAL 1 POWER INPUT STAGE 1 L1 L2 N OUTPUT COIL SIGNAL 3 POWER INPUT STAGE 3 L1 L2 N OUTPUT COIL SIGNAL 4 POWER INPUT STAGE 4 L1 L2 N OUTPUT COIL SIG...

Страница 4: ...g tips and hints see guide for details HIGH VOLTAGE WIRE INSTALLED ACCORDING TO LOCAL WIRING CODE THE CURRENT SHALL NOT EXCEED 25A 3HP AT EACH OUTPUT OUT MAXIMUM 2 WIRES OF SAME SIZE PER BLACK TERMINA...

Страница 5: ...rol over its four stages via the use of the master control or alternatively by manual switch It will also keep you constantly informed of its four stages via LED indications As the LED will be lighted...

Страница 6: ...y access location but away from damaging elements heat cold water direct sunlight Do not drill the face the side the top or the underside of the control Do not install the GE R4 module near high volta...

Страница 7: ...ws provided with the brackets Then mount the enclosure on the wall by inserting screws through the brackets adjustment slots into the wall Make sure to position the enclosure so that all wires extends...

Страница 8: ...GE R4 Electronic module Board L1 L2 N STAGE 1 OUTPUT POWER INPUT COIL SIGNAL 1 L1 L2 N STAGE 2 OUTPUT POWER INPUT COIL SIGNAL 2 NEUTRAL FOR COILS L1 L2 N STAGE 3 OUTPUT POWER INPUT COIL SIGNAL 3 L1 L...

Страница 9: ...of three modes as follows OFF To turn the stages permanently off set the toggle switches to the OFF position ON To turn the stages continually on set the toggles switches to the ON position AUTO To al...

Страница 10: ...NRTL C Protection index IP 54 dust and splashing water Warranty 2 years RELAY OUTPUT Maximum Load For Stages 1 4 1HP 120VAC 3HP 240VAC 25A 250VAC resistive Important Notice Low voltage and high voltag...

Страница 11: ...ower 6 Mounting 7 Layout Board 8 Powering Up Procedure 9 Verify all Connections 9 Hermetically Close the GE R4 9 Put the power on 9 Secure the front panel with a lock 9 Using the toggle switches 9 Out...

Страница 12: ...of God flood fire hail or any other natural disaster Any unauthorized work modification or repair on this product automatically voids the warranty and disclaims the manufacturer from all responsibilit...

Страница 13: ...MAG GE R4 VER 1 0 April 17 2007 www monitrol com...