Specifications
Module GE-R4
DESCRIPTION VALUE
Storage temperature
-4°F to 131°F (-20°C to 55°C)
Operating temperature
32°F to 122°F (0°C to 50°C)
Humidity
90% maximum Non-condensing
Weight 2
lbs.
(0.9Kg)
Size
11” x 17” x 5.5” (27.9 cm x 43.2 cm x 14 cm)
Norms
CSA (NRTL/C)
Protection index
IP 54 (dust and splashing water)
Warranty
2 years
RELAY OUTPUT
Maximum Load For Stages 1 -4
1HP @ 120VAC,
3HP @ 240VAC,
25A @ 250VAC resistive
Important Notice.
- Low-voltage and high-voltage wire must be passed through different conducts at
least 1 foot (30 cm) apart. If low-voltage and high-voltage conduits must be
crossed, the crossing must be at a 90-degree angle.
- All wiring must be made by a certified electrician and conform to local electrical
regulations.