Alarm message table
Messages
Probable Causes
“
Comm. Err.
Bin {1-4}
”
- The mentioned bin module is activated and has not communicated with the GE-
BIN4 controller for a 5-minute period.
“
Check GE-FBT
Mod{1-4}
”
- The mentioned bin’s GE-FBT module cannot provide a stable weight value.
“
Low Level
Bin {1-4}
”
- The mentioned bin’s measured weight is lower than
LOW LIMIT [6]
6
.
“
Max Run Time
Bin {1-4}
”
- The mentioned bin’s auger has run continuously for more than
MAX RUN
TIME [3]
7
.
“
LC {1-8} Bin
{1-4} Defect
”
- The mentioned load cell of the mentioned bin is defective or unplugged for a 5-
minute period.
“
Error Code 1
”
- The system has rebooted 5 times within a 3-minute period or 10 times within a 15-
minute period. This situation will be considered resolved if system does not reboot
for 15 minutes. If this situation persists, contact your distributor.
“
Error Code
{2-5}
”
- If one or more errors of these types occur, contact your distributor.
“
Error Code
6
”
- The MCHIP has remained in the socket for five or more minutes.
6
Refer to the
BIN {1-4} SETUP (2.1.1-4)
screen for more information on this parameter.
7
Refer to the
AUGER {1-4} SETUP (2.2.1-4)
screen for more information on this parameter.
www.monitrol.com
Содержание GE-BIN4
Страница 5: ...GE BIN4 WIRING DIAGRAM LAYOUT GE BIN 4 Section A 5 WIRING DIAGRAM GE FBT GE LIM www monitrol com...
Страница 8: ...GE BIN4 INSTALLATION Section B 8 GE BIN4 INSTALLATION GE BIN4 SECTION B www monitrol com...
Страница 18: ...GE BIN4 USER S GUIDE Section C 18 GE BIN4 USER S GUIDE GE BIN4 SECTION C www monitrol com...
Страница 51: ...GE BIN4 INDEX WARRANTY GE BIN4 Section D 51 INDEX WARRANTY GE BIN4 SECTION D www monitrol com...
Страница 55: ...www monitrol com...
Страница 56: ...GE BIN4 VER 1 9 March 18 2020 www monitrol com...