background image

4

ENGLISH

Fig. 9

3

1

4

2

7. TEST OF THE AUTOMATED SYSTEM

Check operating efficiency of the automated system and all

accessories connected to it.
Hand the "User's Guide" page to the Client, explain correct

operation and use of the operator and indicate the potentially

dangerous areas of the automated system.

8. MANUAL OPERATION

If the gate has to be operated manually, 

turn off power

 and

proceed as follows:
1) Slide the protective tab, Fig.9 / 1.

2) Fit the key and turn it through 90°, Fig.9 / 2.
3) Lift up the manoeuvre lever, Fig.9 / 3.
4) To release the operator, turn the manoeuvre lever

through 180°, as shown by the arrow on the release

system Fig.9 / 4.

Open or close the leaves manually.

Attention:

 to keep the operator in manual operation mode,

the operator must be 

released and without power

.

9. RESTORING NORMAL OPERATION

To restore normal operation mode of the automated system,

turn the metal lever clockwise, close the cover and switch

on power to the system.
Carry out some manoeuvres in order to check if all functions

of the automated system have been correctly restored.

10.MAINTENANCE

Periodically check the gate structure and particularly check

the perfect efficiency of the hinges.
Periodically check the correct adjustment of the electronic

anti-crushing and the efficiency of the release system

enabling the manual operation (see related paragraph).
The safety devices installed on the system need to be checked

every six months.

11.REPAIRS

For any repairs, contact authorised Repair Centres.

Отзывы: