4
ENGLISH
Fig. 9
3
1
4
2
7. TEST OF THE AUTOMATED SYSTEM
Check operating efficiency of the automated system and all
accessories connected to it.
Hand the "User's Guide" page to the Client, explain correct
operation and use of the operator and indicate the potentially
dangerous areas of the automated system.
8. MANUAL OPERATION
If the gate has to be operated manually,
turn off power
and
proceed as follows:
1) Slide the protective tab, Fig.9 / 1.
2) Fit the key and turn it through 90°, Fig.9 / 2.
3) Lift up the manoeuvre lever, Fig.9 / 3.
4) To release the operator, turn the manoeuvre lever
through 180°, as shown by the arrow on the release
system Fig.9 / 4.
Open or close the leaves manually.
Attention:
to keep the operator in manual operation mode,
the operator must be
released and without power
.
9. RESTORING NORMAL OPERATION
To restore normal operation mode of the automated system,
turn the metal lever clockwise, close the cover and switch
on power to the system.
Carry out some manoeuvres in order to check if all functions
of the automated system have been correctly restored.
10.MAINTENANCE
Periodically check the gate structure and particularly check
the perfect efficiency of the hinges.
Periodically check the correct adjustment of the electronic
anti-crushing and the efficiency of the release system
enabling the manual operation (see related paragraph).
The safety devices installed on the system need to be checked
every six months.
11.REPAIRS
For any repairs, contact authorised Repair Centres.
Содержание E-volution 01
Страница 1: ...E volution 01...