background image

COMPAS 24 - COMPAS 24C

ENGLISH

Guide for the installer

Page

Thank  you  for  choosing  our  product.  GENIUS  is  sure  you  will  get 

the performances you expect to satisfy your requirements. All our 

products are the result of a many years’ experience in the field of 

the automated systems, strengthened by being part of a world 

leading group in this sector.

  In  the  middle  of  the  manual  you  will  find  a  detachable 

booklet containing all the images for the installation.

The COMPAS automated system consists of a non-reversing electro-

mechanical operator available in two versions:

• COMPAS 24C with built-in control unit

• COMPAS 24 without control unit

The operator was designed for automating the opening of gates 

with one or two leaves, with maximum length of 2.5m. 

A handy, safe releases system, with personalised key, moves the 

leaf in case of a power cut or fault.

The two articulated arms are designed for moving gates with very 

large  pilasters.  The  distance  between  the  hinge  and  the  gear-

motor securing point can be up to 220 mm. Thanks to the special 

geometry of the two arms, all possible shearing points have been 

eliminated.

IMPORTANT WARNINGS FOR THE INSTALLER

Carefully read the whole manual before beginning to install the 

operator.

Store the manual for future reference.

The correct operation and the declared technical specifications 

are only valid if the instructions given in this manual are strictly 

observed and only GENIUS accessories as well as safety device 

are used.

To  guarantee  an  adequate  level  of  safety  of  the  automated 

system, the use of a control unit with an adjustable electronic 

clutch is necessary due to the lack of a mechanical clutch .

The automated system was designed and built to control vehicle 

access. Avoid any other use.

The  operator  cannot  be  used  to  move  safety  exits  or  gates 

installed on emergency routes (escape routes).

Do not transit when the rod is moving.

Anything not expressly specified in this manual is not permitted.

1. COMPONENTS (Fig. 1)

Pos.

Description

a

Gearmotor

b

Transformer

c

Control unit (for master motor only)

d

Release device

e

Receiver module (optional)

f

Mechanical stops

g

Transmission arm

h

Covering housing

i

Rear bracket

j

Lower housing

2. TECHNICAL SPECIFICATIONS

Model

Compas 24C

Compas

Power supply

230 V~

/

Electric motor

24 V

Absorbed power

120 W

40 W

Max torque

250 N/m

Nominal torque

165 N/m

Max angular speed

13 °/sec

Max leaf 

a b

2.5 m

Max leaf weight. 

b

See graph fig. 2

Use frequency at 20°C

80 cycles/day

Consecutive cycles at 20°C

30

Mximum continuous operating time

O.T. 17 min.

Protection Class

IP44

Operating ambient temperature

 -20°C     +55°C

Noise level

<70 dB (A)

Operator weight

8.7 Kg

7 Kg

Dimensions

See fig. 3

a

  For leaves with a length L>2m, an electric lock must be installed 

to guarantee locking the leaf.

b

  The weight 

P

 of the leaf is a function of the length 

L

. Check if your 

leaf is in the zone shown in the graph of fig. 2.

3. ELECTRICAL CONNECTIONS (Fig. 4)

Pos.

Description

Cables section

a

Gearmotor COMPAS 24 C

3x2.5 mm

2

b

Gearmotor COMPAS 24 

a

2x2.5 mm

2

c

Flashing lamp

2x1.5 mm

2

d

Key-operated selector switch

2x0.5 mm

2

e

Photocell transmitter

2x0.5 mm

(BUS)

f

Photocell receiver

2x0.5 mm

(BUS)

g

Electric lock 

b

2x1 mm

2

Only for two leaf applications.

b

 Obligatory for leaf L>2m.

  The lay-out below refers to an installation with two motors, 

with all safety and signalling devices connected.

  For two-motor applications, use a cable, type H05RN-F to 

connect the MASTER and SLAVE operators.

4. INSTALLATION

4.1. PRELIMINARY CHECKS

To ensure a correctly operating automated system, the structure of 

the gate to be moved must satisfy the following requirements:

The  mechanical  construction  elements  must  comply  with  the 

provisions of the EN12604 and EN 12605 standards.

leaf  length  must  conform  to  the  operator  characteristics  (see 

paragraph 2)

sturdy, rigid gate structure, suitable for the automated system

smooth, uniform gate movement, without any friction and jam-

ming during the entire opening;

adequately sturdy hinges, in good condition

an efficient earth socket for connection of the operator

  We advise you to carry out the metalwork jobs if any, before 

installing the automated system.

  The condition of the gate structure directly influences the re-

liability and safety of the automated system.

  If the leaf to be motorised incorporates a door for the pedestrian 

passage it is compulsory to add a safety switch on the door, 

connected to the stop input, in order to inhibit the operation 

of the automated system when the door is open.

  The gearmotor cannot be used to move safety exits or gates 

fitted on emergency routes (escape routes).

4.2 INSTALLATION DIMENSIONS

Procedure for finding the securing position of the operator, using 

Fig. 5 to help you:

measure dimension “

A

” of the gate and trace a horizontal line 

Содержание COMPAS 24

Страница 1: ...COMPAS 24 COMPAS 24 C GUIda per l installatore Guide for the installer Guide pour l installateur Gu a para el instalador Leitfaden f r den Installateur Gids voor de installateur...

Страница 2: ...4 5 6 7 8 9 10 11 12 13 14 15 in the Standards indicated at point 10 The safety devices EN 12978 standard protect any danger areas against mechanical movement Risks such as crushing dragging and shear...

Страница 3: ...ede Anlage wird der Einsatz von mindestens einem Leuchtsignal empfohlen sowie eines Hinweisschildes das ber eine entsprechende Befestigung mit dem Aufbau des Tors verbunden wird Dar ber hinaus sind di...

Страница 4: ...nts of the following EEC directives 2006 95 EC Low Voltage directive 2004 108 EC Electromagnetic Compatibility directive and also declares that it is prohibited to put into service the machinery until...

Страница 5: ...ed power 120 W 40 W Max torque 250 N m Nominal torque 165 N m Max angular speed 13 sec Max leaf a b 2 5 m Max leaf weight b See graph fig 2 Use frequency at 20 C 80 cycles day Consecutive cycles at 20...

Страница 6: ...hown in Fig 14 ref b Take the operator back to the work position see paragraph 6 1 2 3 4 5 6 7 8 9 10 11 12 13 4 4 WIRING THE OPERATOR When you have finished securing the operator you can wire it Ther...

Страница 7: ...ATIONS Applications other than those in this manual are EXPRESSLY PROHI BITED 8 MAINTENANCE To ensure correct long term operation and a constant level of sa fety we advise you to generally control the...

Страница 8: ...COMPAS 24 COMPAS 24C Immagini Images Images Im genes Bilder Afbeeldingen Pag Fig 01 Fig 02 Fig 03 Fig 04 Fig 06 Fig 07 Fig 05...

Страница 9: ...COMPAS 24 COMPAS 24C Immagini Images Images Im genes Bilder Afbeeldingen Pag Fig 08 Fig 09 Fig 10 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15...

Страница 10: ...COMPAS 24 COMPAS 24C Immagini Images Images Im genes Bilder Afbeeldingen Pag Fig 16 Fig 17 Fig 18 Fig 19...

Страница 11: ...hat pre vent the gate from closing when there is an obstacle in the area they protect The system ensures mechanical locking when the motor is not ope rating and therefore for gates of less than 2m in...

Страница 12: ...ng 1 Velligheldsvoorziening 1 Dispositivo di sicurezza 2 Safety device 2 dispositif de s curit 2 Dispositivo de seguridad 2 Scherhelt svorrichtung 1 Velligheldsvoorziening 2 Coppia di fotocellule 1 Pa...

Страница 13: ...chnicien T cnico Techniker Technicus Cliente Customer Client Cliente Kunde Klant 4 Tecnico Technicia Technicien T cnico Techniker Technicus Cliente Customer Client Cliente Kunde Klant 5 Tecnico Techni...

Страница 14: ...el derecho dejando inmutadas las caracter sticas esenciales de los aparatos de aportar en cualquier momento y sin comprometerse a poner al d a la presente publicaci n todas las modificaciones que cons...

Отзывы: