PCB assembly is a kind of sophisticated electronic circuit board.    A scanner mainly includes the 

following items: Scan Board, CCD Board, Switch Board, Panel Board, etc..    Therefore, well 

packing will be required when sending them by post or courier. 

1.

 

Some sophisticated IC components are mounted on the PCB assembly, hence it is necessary to 

pack each PCB assembly with a separate static protecting beg, in order to avoid static electricity. 

2.

 

CCD sensor is the most important component on the CCD Board, hence, CCD sensor must be 

covered by a protecting sheet (shown as below) when mailing it, in order to prevent from scratch. 

 

3.

 

Reliable external packing is also very important when sending the PCB assembly by post, in that 

it would avoid unnecessarily lost or damage.   

S

S

h

h

o

o

r

r

t

t

 

 

o

o

f

f

 

 

s

s

p

p

a

a

r

r

e

e

 

 

p

p

a

a

r

r

t

t

s

s

 

 

w

w

h

h

i

i

l

l

e

e

 

 

r

r

e

e

p

p

a

a

i

i

r

r

i

i

n

n

g

g

 

 

a

a

 

 

s

s

c

c

a

a

n

n

n

n

e

e

r

r

 

 

If you are short of spare parts when you have some scanners waiting to be repaired, it would be 

recommended to take the necessary parts from one scanner, so that you may have the as many as 

scanners be repaired and sent back to your customer, and left only one or few scanners waiting for 

spare parts sending from KYE. 

CCD sensor, covered by a screen 

protecting sheet 

Содержание ColorPage-Vivid 1200XE USB

Страница 1: ...ColorPage Vivid 1200XE USB...

Страница 2: ...place the Motor 9 How to Replace the Gear Wheel 10 How to replace the Scan board 10 How to Replace the CCD Board 11 How to Replace the FFC Cable 12 How to Replace the Lamp 13 How to Replace the Mirror...

Страница 3: ...s from Customers Analyzing possible malfunction causes Deciding proceeding the rectification methods Replacing necessary defective parts Return the scanners with proper repackaging to customers Verify...

Страница 4: ...mage 5 Others such as the Broken of the Defection Mirror or the Broken of the Document Glass etc Solutions of the problems z Main lamp unilluminated Main lamp unilluminated Mechanical Electronic Probl...

Страница 5: ...or Upper Housing Base Housing or Belt is not in the right position Defective Gear Replace Scan Board Replace Motor Re install Upper Housing Base Housing or Belt Replace Gear Motor Problem Analyze the...

Страница 6: ...Please refer to the related chapters for solving these problems C Ch ha ap pt te er r 2 2 Poor Scanning Image Electronic Mechanical Defective CCD Board Incorrect CCD Focus Defective Scan Board Defecti...

Страница 7: ...g transportation The Auto Lock Key is located on the base of the scanner Turn over the Scanner then you can see the Auto Lock Key figure 2 1 2 Before using the Scanner please make sure the scanner to...

Страница 8: ...o Disassembly the Scanner figure 2 2 1 Step 1 We will find a mortise like and a tenon like device which fasten up the top cover and the base frame figure 2 2 2 Step 2 Use fingers to exert to turn outs...

Страница 9: ...the Glass Stop Block out of the glass holder and release the space between the edge of the Document Glass and the Upper Housing figure 2 3 3 Step 3 After the Glass Stop Block is removed turn the Docu...

Страница 10: ...f the base frame Take out the Sliding Axle from the module so lightly figure 2 4 3 Step 3 Hold on the Timing Belt and turn the spring Take off the other end by the same way then you can easily take of...

Страница 11: ...the screws Loosen the screws from fixed plate of idle arm with a screwdriver figure 2 5 2 Step 2 Disconnect the connector of the Motor that is connected to the Scan Board Then take off the Motor figur...

Страница 12: ...g out the E Ring please be careful not to let it gone How to replace the Scan board figure 2 7 1 Step 1 Before gentle pull up the scan board from the slot on the button case disconnect the cable of FF...

Страница 13: ...2 8 2 Step 2 Dissolve the green seal on the screws on the scan board before you loosen them figure 2 8 3 Step 3 Disconnect the connector of Inverter then you can take off the CCD Board Notice To Insta...

Страница 14: ...bend the FFC Cable and result system failure figure 2 9 2 Step 2 Pull out another end of the FFC Cable which is attached to the CCD Board figure 2 9 3 Step 3 When installing the FFC Cable ensure that...

Страница 15: ...amp figure 2 10 1 Step 1 Disconnect the CCD Connector that is attached to the CCD Board Loosen the screw then you can take off the Inverter Disconnect the Lamp Connector that is attached to the Invert...

Страница 16: ...1 Loosen the 2 pcs screws of module cover with a screwdriver figure2 11 2 Step 2 Exert to push forward then you can take apart the module cover figure 2 11 3 Step 3 You can see module cover module fi...

Страница 17: ...take out the mirror fix clips by tweezers figure 2 11 7 figure 2 11 8 Reflection side Non reflection side Step 7 When installing Mirrors use one hand to insert the mirror into the position that it bel...

Страница 18: ...1 Step 1 Need to loosen the 2 pcs screws then you can open the lens cover figure2 12 2 Step 2 Loosen the 2 pcs screws of lens cover with a screwdriver figure 2 12 3 Step 3 You can replace or adjust l...

Страница 19: ...o o A Ad dj ju us st t C CC CD D R Re es so ol lu ut ti io on n a an nd d P Pi ix xe el ls s A Ad dj ju us st tm me en nt t F Fl lo ow ws s z Operation Flow Start Module Installation Preparation Scann...

Страница 20: ...o of f F Fa ac ci il li it ti ie es s a an nd d T To oo ol ls s figure 3 1 1 Facilities 1 Computer 2 CCD Adjustment Software figure 3 1 2 Tools 1 Module Horizontal Resolution 2 600dpi 1200dpi 2 Screw...

Страница 21: ...Pr ro oc ce ed du ur re es s How to Adjust the Lens Resolution figure 3 2 1 Step 1 1 Connecting the scanner to the computer And activating the adjustment program according to the model you want to rep...

Страница 22: ...dule Horizontal Resolution Adjustment tool 2 Loosen the screws then adjust lens resolution of the front and rear use the tweezers figure 3 2 4 Step 3 1 Slightly adjust the position of lens till the wa...

Страница 23: ...you may solidly fasten the screws Notice A The Scanner Center value for the Module Horizontal Resolution Adjustment tool is between 10 to 10 B The CCD points value for the Module Horizontal Resolutio...

Страница 24: ...rder to avoid static electricity 2 CCD sensor is the most important component on the CCD Board hence CCD sensor must be covered by a protecting sheet shown as below when mailing it in order to prevent...