21
G
uide
S
ervice
ColorPage-Vivid 1200XE USB
How to Adjust the CCD Points & Center Value
figure 3.3.1.
Step 1
1.
Loosen the screws that adjust the CCD Board.
2.
With one hand to adjust the Scanner Center
slightly to the right or left.
3.
After the Scanner Center is set, hold the CCD
Board with one hand, and then adjust the CCD
points slightly up or down.
4.
When adjustments have been done, and then
you may solidly fasten the screws.
Notice:
A.
The Scanner Center value for the Module
Horizontal Resolution Adjustment tool is
b10 to -10).
B.
The CCD points value for the Module
Horizontal Resolution Adjustment tool is
between 3
±
1).
figure 3.3.2
.
Step 2
1.
Slightly adjust the position of CCD Board till
the waveform shown in the computer screen has
reached its maximum wavelength.
2.
Fasten the screws temporarily, but do not solidly
fasten the screws.
figure 3.3.3.
Step 3
1.
Fasten the screws , then place green seal onto
the screws.
2.
Re-install the Scanner Module back to its
original position.