14
U
NSCHEDULED
M
AINTENANCE
A
Replacing the Light Bulb.
•
To release the light cover.
– Pressin on center tab and lower lens.(
Figure 1
).
– Replace the light bulb with a rough service bulb of
no
more than 100 Watts
.
•
Raise Light Cover to close.
T
ROUBLESHOOTING
I
F THERE IS ANY TROUBLEWITH THE
O
PENER
,
TRY
THESESOLUTIONS BEFORE CALLING THE
H
ELP
N
UMBER
.
NOTE
In all cases, watch the opener
’s lights for any flashing
trouble codes.Refer to the Flashing Light Trouble Codes
on page 16 for the problem cause and remedy.
FRONT OF
UNIT
Figure 1
Light Lens
I
MPORTANT
S
AFETY
I
NSTRUCTIONS
WARNING:TO REDUCE
THERISKOFSEVERE
INJURY OR DEATH
1
READ ANDFOLLOW ALL INSTRUCTIONS.
2
Never let children operate or play with the Door
Controls. Keep theRemote Control awayfrom children.
3
Always keep the moving door in sight and away from
people and objects until the door is completely closed.
NOONESHOULDCROSSTHEPATH OFA MOVINGDOOR.
4
NEVERGO UNDERASTOPPED,PARTIALLYOPEN DOOR.
5
Test Opener monthly. The door MUST reverse on
contact with a 1-1/2" high object (or a 2" x 4" board
laid flat) at the center of the doorway on the floor.
After adjusting either the Force or the Limit of travel,
retest the Door Opener. Failure to adjust the Opener
properly may cause severe injury or death.
6
When possible use theEmergencyRelease only when
the door is closed. Use caution when using this
Release with the door open. Weak or broken springs
are capable of increasing the rate of door closure and
increasing the risk of severe injury or death.
7
KEEPGARAGEDOORSPROPERLYBALANCED. See
Owner's Manual. An improperly balanced door
increases the risk of severe injury or death. Have a
Genie Factory Authorized Dealer make repairs to
cables,spring assemblies,and other hardware.
8
SAVETHESEINSTRUCTIONS.
WARNING
Use theWallConsole included with Opener. Any other wall
consolecan cause theOpener to operate unexpectedly
and the light tostop working.
Trouble 1:
O
PENER DOES NOT OPERATE FROM
THE REMOTE OR WALL CONTROL
A
Check that the
opener’s AC outlet has power.Plug a lamp into the
outlet to check.
B
The motor
’s automatic thermal shutoff switch may have
been activated from repeated use
(opener’s lights will
flash 4 times). Wait 30 minutes for the motor to cool
down and retry.
C
Check the wall control wiring at the wall control
’s and
opener’s terminals and be sure that the remote is
programmed into the opener.
Trouble 2:
O
PENER TRIES TO OPERATE
,
BUT THE
DOOR DOES NOT MOVE
A
A door spring may have broken.Visually inspect the door
hardware for any broken springs.Have a qualified garage door service
professional repair the door if any hardware is broken.
B
In cold weather climates, check that the door is not frozen to the
ground or that snow buildup is not blocking the door.
C
If the opener light flashes 4 times, the door force setting
may be too low.Adjust the force.
Trouble 3:
O
PENER OPERATES
,
BUT THE DOOR
DOES NOT MOVE
A
Check that the carriage is engaged to the bullet/belt. The
carriage release lever must be in the horizontal position in order for it
to engage.
Trouble 4:
T
HE DOOR STARTS TO OPEN BUT
STOPS BEFORE FULLY OPENING
A
If the opener light flashes 4 times, the open force setting may be
too low. Reset the force.
B
The door hardware may be binding causing the door force setting
to be exceeded.Disengage the carriage and manually check the door
movement and balance.Lubricate the door hardware as recommended
by the manufacturer.
Trouble 5:
T
HE DOOR DOES NOT OPEN
COMPLETELY
A
Adjust the open limit setting.
Trouble 6:
T
HE DOOR DOES NOT CLOSE
COMPLETELY
A
Adjust the close limit setting.