4-16
GTH-5519
Part No. 1272852
September 2016
Section 4 • Fault Codes
SPN
FMI Short Text Detail
4366
5
SCR tank heating valve primary side; open load
4366
12
SCR-heater relay urea tank powerstage output; over temperature
4366
3
SCR Tank heating valve; short circuit to battery
4366
4
SCR Tank heating valve; short circuit to ground
4375
5
Urea pump motor; open load
4375
3
Urea pump motor; short circuit to battery
4375
4
Urea pump motor; short circuit to ground
4334
0
Physical range check high for Urea Pump Pressure
4334
1
Physical range check low for Urea Pump Pressure
4334
0
Urea pump pressure sensor; high signal not plusible
4334
1
Urea pump pressure sensor; low signal not plausible
4334
3
Sensor error urea pump pressure; signal range check high
4334
4
Sensor error urea pump pressure; signal range check low
4376
5
SCR reversing valve; open load
4376
12
SCR reversing valve; over temperature
4376
3
SCR reversing valve; short circuit to battery
4376
4
SCR reversing valve; short circuit to ground
3031
0
AdBlue-Tank temperature: maximum exceeded
3031
1
DEF-Tank temperature: below minimum
3031
3
Sensor error urea tank temperature; short circuit to battery
3031
4
Sensor error urea tank temperature; short circuit to ground
97
12
Water in fuel level prefilter; maximum value exceeded
523946
0
Zerofuel calibration injector 1 (in firing order); maximum value exceeded
523947
0
Zerofuel calibration injector 2 (in firing order); maximum value exceeded
523948
0
Zerofuel calibration injector 3 (in firing order); maximum value exceeded
523949
0
Zerofuel calibration injector 4 (in firing order); maximum value exceeded
523950
0
Zerofuel calibration injector 5 (in firing order); maximum value exceeded
523951
0
Zerofuel calibration injector 6 (in firing order); maximum value exceeded
523946
1
Zerofuel calibration injector 1 (in firing order); minimum value exceeded
523947
1
Zerofuel calibration injector 2 (in firing order); minimum value exceeded
523948
1
Zerofuel calibration injector 3 (in firing order); minimum value exceeded
523949
1
Zerofuel calibration injector 4 (in firing order); minimum value exceeded
523950
1
Zerofuel calibration injector 5 (in firing order); minimum value exceeded
523951
1
Zerofuel calibration injector 6 (in firing order); minimum value exceeded
FAULT CODES
Содержание GTH-5519
Страница 5: ...September 2016 Part No 1272852 GTH 5519 v INTRODUCTION Serial Number legend...
Страница 6: ...vi GTH 5519 Part No 1272852 September 2016 This page intentionally left blank...
Страница 12: ...xii GTH 5519 Part No 1272852 September 2016 TABLE OF CONTENTS This page intentionally left blank...
Страница 58: ...3 36 GTH 5519 Part No 1272852 September 2016 Section 3 Repair Procedures This page intentionally left blank...
Страница 127: ...September 2016 Section 5 Schematics 5 27 5 28 Hydraulic Schematic...