August 2018
Part No. 57.4400.9220GT
GTH-2506 GTH-3007
2-5
Section 2 • Specifications
Function Manifold
Specifications
Function Manifold
System relief valve pressure, maximum
(measured at test port TP1)
4060 psi
280 bar
Fork tilt relief valve pressure, maximum
(measured at test port TP1)
4350 psi
300 bar
Boom telescopic cylinder relief valve
pressure, maximum
(measured at test port TP1)
1450 psi
100 bar
Secondary Function Valves
Steer relief valve pressure, maximum
2537 psi
175 bar
Steer anti-shock relief valve pressure,
maximum
3408 psi
235 bar
Parking brake relief valve pressure,
maximum (measured at test port TP5)
360 psi
25 bar
Service brake pressure, maximum
(measured at test port TP4)
1160 psi
80 bar
SPECIFICATIONS
Air Conditioner Refrigerant
Specifications
System Full Charge
R134a
750 g
1 lbs 10 oz
Continuous improvement of our products is
a Genie policy. Product specifications are
subject to change without notice.