![Genie GTH-1544 Скачать руководство пользователя страница 99](http://html1.mh-extra.com/html/genie/gth-1544/gth-1544_service-and-repair-manual_2212081099.webp)
September 2016
Part No.1272857
GTH-1544
4-27
Section 4 • Fault Codes
1109
2
Engine shut off demand ignored
1136
0
Physikal range check high for ECU temperature
1136
1
Physikal range check low for ECU temperature
1136
3
Sensor error ECU temperature; signal range check high
1136
4
Sensor error ECU temperature; signal range check low
1176
3
Sensor error pressure sensor upstream turbine; signal range check high
1176
4
Sensor error pressure sensor downstream turbine; signal range check high
1180
0
Physical range check high for exhaust gas temperature upstream turbine
1180
0
Turbocharger Wastegate CAN feedback; warning threshold exceeded
1180
0
Exhaust gas temperature upstream turbine; warning threshold exceeded
1180
1
Physical range check low for exhaust gas temperature upstream turbine
1180
1
Turbocharger Wastegate CAN feedback; shut off threshold exceeded
1180
1
Exhaust gas temperature upstream turbine; shut off threshold exceeded
1180
3
Sensor error exhaust gas temperature upstream turbine; signal range check high
1180
4
Sensor error exhaust gas temperature upstream turbine; signal range check low
1180
11
Sensor exhaust gas temperature upstream turbine; plausibility error
1188
2
Wastegate; status message from ECU missing
1188
7
Wastegate actuator; blocked
1188
11
Wastegate actuator; internal error
1188
11
Wastegate actuator; EOL calibration not performed correctly
1188
11
Wastegate actuator; over temperature (> 145°C)
1188
11
Wastegate actuator; over temperature (> 135°C)
1188
11
Wastegate actuator; operating voltage error
1188
13
Wastegate actuator calibration deviation too large, recalibration required
1231
14
CAN-Bus 1 "BusOff-Status"
1235
14
CAN-Bus 2 "BusOff-Status"
1237
2
Override switch; plausibility error
1322
12
Too many recognized mis
fi
res in more than one cylinder
1323
12
Too many recognized mis
fi
res in cylinder 1 (in
fi
ring order)
1324
12
Too many recognized mis
fi
res in cylinder 2 (in
fi
ring order)
1325
12
Too many recognized mis
fi
res in cylinder 3 (in
fi
ring order)
1326
12
Too many recognized mis
fi
res in cylinder 4 (in
fi
ring order)
1327
12
Too many recognized mis
fi
res in cylinder 5 (in
fi
ring order)
1328
12
Too many recognized mis
fi
res in cylinder 6 (in
fi
ring order)
1639
0
Sensor error fan speed; signal range check high
1639
1
Sensor error fan speed; signal range check low
FAULT CODES
Содержание GTH-1544
Страница 5: ...September 2016 Part No 1272857 GTH 1544 v Serial Number Legend 6 5 5...
Страница 6: ...vi GTH 1544 Part No 1272857 September 2016 This page intentionally left blank...
Страница 12: ...xii GTH 1544 Part No 1272857 September 2016 This page intentionally left blank...
Страница 24: ...2 12 GTH 1544 Part No 1272857 September 2016 Section 2 Specifications This page intentionally left blank...
Страница 72: ...3 48 GTH 1544 Part No 1272857 September 2016 Section 3 Repair Procedures This page intentionally left blank...
Страница 147: ...September 2016 Section 5 Schematics 5 33 5 34 Hydraulic Schematic Deutz Engine Deutz engine Sheet 1 of 2...
Страница 150: ...5 37 5 38 September 2016 Section 5 Schematics Hydraulic Schematic Perkins Engine Perkins engine Sheet 2 of 2...
Страница 151: ......