Section 4 • Repair Procedures
REV B
June 2007
4 - 64
GS-2668 RT • GS-3268 RT
Part No. 112657
MANIFOLDS
9-7
Valve Coils
How to Test a Coil
A properly functioning coil provides an
electromagnetic force which operates the solenoid
valve. Critical to normal operation is continuity
within the coil. Zero resistance or infinite resistance
indicates the coil has failed.
Since coil resistance is sensitive to temperature,
resistance values outside specification can
produce erratic operation. When coil resistance
decreases below specification, amperage
increases. As resistance rises above specification,
voltage increases.
While valves may operate when coil resistance is
outside specification, maintaining coils within
specification will help ensure proper valve function
over a wide range of operating temperatures.
Electrocution/burn hazard. Contact
with electrically charged circuits
could result in death or serious
injury. Remove all rings, watches
and other jewelry.
Note: If the machine has been in operation, allow
the coil to cool at least 3 hours before performing
this test.
1 Tag and disconnect the wiring from the coil to
be tested.
2 Test the coil resistance using a multimeter set
to resistance (
Ω)
. Refer to the Valve Coil
Resistance Specification table.
Result: If the resistance is not within the
adjusted specification, plus or minus 10%,
replace the coil.
Valve Coil Resistance
Specification
Note: The following coil resistance specifications
are at an ambient temperature of 68°F / 20°C. As
valve coil resistance is sensitive to changes in air
temperature, the coil resistance will typically
increase or decrease by 4% for each 18°F / 20°C
that your air temperature increases or decreases
from 68°F / 20°C.
Description
Specification
Solenoid valve, 2 position 2 way
9
Ω
12V DC with diode (schematic item AI)
Solenoid valve, 2 position 2 way
7.5
Ω
12V DC (schematic item BB)
Solenoid valve, 3 position 4 way
7.5
Ω
12V DC (schematic item BD)
Solenoid valve, 2 position 2 way
8.2
Ω
10V DC (schematic items CA, CB, CC and CD)
Solenoid valve, 2 position 3 way
6
Ω
12V DC (schematic item DA)
Solenoid valve, 2 position 2 way
8.8
Ω
12V DC with diode (schematic items FB and FK)
Solenoid valve, 2 position 4 way
5
Ω
12V DC with diode (schematic items FD, FQ and FT)
Solenoid valve, 3 position 4 way
5
Ω
12V DC with diode (schematic items FE and FR)
Solenoid valve, 3 position 4 way
8.8
Ω
12V DC with diode (schematic item FF)
Solenoid valve, 2 position 3 way
8.8
Ω
12V DC with diode (schematic item FP)
Proportional valve,
5
Ω
12V DC (schematic item FU)
Содержание GS-2668 RT
Страница 4: ...June 2007 GS 2668 RT GS 3268 RT Part No 112657 iv This page intentionally left blank ...
Страница 14: ...June 2007 GS 2668 RT GS 3268 RT Part No 112657 xiv This page intentionally left blank ...
Страница 148: ...Section 5 Fault Codes June 2007 5 6 GS 2668 RT GS 3268 RT Part No 112657 This page intentionally left blank ...
Страница 153: ...Section 6 Schematics June 2007 Part No 112657 GS 2668 RT GS 3268 RT 6 5 This page intentionally left blank ...
Страница 159: ...Section 6 Schematics June 2007 Part No 112657 GS 2668 RT GS 3268 RT 6 11 This page intentionally left blank ...
Страница 163: ...Section 6 Schematics June 2007 Part No 112657 GS 2668 RT GS 3268 RT 6 15 This page intentionally left blank ...
Страница 167: ...Section 6 Schematics June 2007 Part No 112657 GS 2668 RT GS 3268 RT 6 19 This page intentionally left blank ...
Страница 171: ...Section 6 Schematics June 2007 Part No 112657 GS 2668 RT GS 3268 RT 6 23 This page intentionally left blank ...
Страница 175: ...Section 6 Schematics June 2007 Part No 112657 GS 2668 RT GS 3268 RT 6 27 This page intentionally left blank ...
Страница 182: ...Section 6 Schematics June 2007 6 34 GS 2668 RT GS 3268 RT Part No 112657 This page intentionally left blank ...
Страница 184: ... from serial number GS6805 44771 Part No 112657 Rev C2 Service Manual GS 2668 RT GS 3268 RT ...