www.GenieCompany.com/commercial
|
800.843.4084
©2012 The Genie Company
|
GCL-GTss
33" MAX
DOOR 4'-10"
10 58 "
5"
HIGHEST POINT
OF DOOR
DURING TRAVEL
13 11
16 "
5 13
16 "
7 13
16 "
7 9
16 "
MOUNTING BRKT
GHX-TROLLEY-1/2,3/4 & 1HP
GCL-GT
|
HEAVY-DUTY GEAR HEAD TROLLEY OPERATOR
1. Maximum door weight, and not the square footage, is the critical factor in selecting the proper operator.
2. Max Door Height 24’
3. For “Commercial Steel Insulated” category, various “backer” options are available. The chart above is based in all cases on the thickest backer available.
4. “PU-FIP” stands for “polyurethane, foamed-in-place”. If no notation is present, insulation is “polystyrene laid-in-place”.
Notes:
Accessories and Options
• Timer to Close Module
Timed close set via the LCD display from 2 seconds up to 5 minutes. Includes
pre-close warning contacts, timer hold input, auxiliary open input, normally
closed safety input, and monitored edge input.
• Auxiliary Output Module
Provides relay contacts at the open, close, and mid-stop limits. Contacts
for 5-minute lamp, and “ADA” contacts set via LCD display to warn during
opening, closing or both.
• Intellicode
®
I Transmitters
Available in single up to four button, or open/close/stop models.
• Environmental Modifications
Totally enclosed non-ventilated, or fan-cooled motors available - Must
be ordered from the factory. Nema 4 or Nema 4X environmental
modifications - Must be ordered from the factory.
• UL325-2010 Approved Reversing Devices
The installation of a monitored external entrapment device is required for
momentary contact close operation on all commercial door operators. Only
the following devices, when purchased through Genie, are UL-Approved
for use to meet this requirement:
• Safe-T-Beam
®
Photoeye Kit with adjustable bracket P/N 38176R.S
1
• Impact-protected Commercial Photoeye Kit P/N OPAKPE.S
• MillerEdge ME/MT/CPT (DC or T3) 2-wire edge sensor. Must be
used with TCM (OPABTCGX.S) or Interface Module (OPAKMEIGX.S).
• Nema 4 Photoeyes P/N OPAKPEN4GX.S
1
— Default device when operator is ordered.
Construction
• Motor
AC continuous-duty motor. Motor replaceable without changing limits.
Thermally protected.
• Drive
Primary — Heavy-duty worm gear running in oil bath.
All-weather synthetic lube for low/high temp operation.
Secondary — Heavy-duty chain and sprocket reduction.
• Brake
24VDC disc brake standard.
• Friction Clutch
Adjustable clutch to help protect against door and operator damage.
• Precision Radial Ball Bearings
Used exclusively throughout the operator powertrain.
• Rail Assembly
2” heavy-gauge roll-formed angle with nylon chain guides.
• Emergency Disconnect
Drawbar disconnect via pull cord for manual operation of door.
• Pre-wired to accept:
- Monitored entrapment device such as photo eyes.
- Single or 3-button control stations.
- External interlock switches.
MAX DOOR SIZE (SQ*FT) - SECTIONAL
Door Series
Commercial Steel Insulated & Non-Insulated
Thermospan
®
ThermoMark
™
Aluminum
216
216
Ins.
220
220 Ins.
2415
2415
Ins.
2411
2411
Ins.
125
150
200
200-20
5150
5200
451
452
Flush
Ribbed
Insulated
Insulated
Model
Max
Door Wt.
(lbs)
16GA.
16GA.
Ins.
20GA.
Steel
20GA.
Ins.
24GA.
24GA.
Ins.
Nominal
24GA.
Nominal
24GA.
Ins.
PU-FIP
PU-FIP
1.38”
PU-FIP
2”
PU-FIP
2”
20GA.
Ext.
PU-FIP
Raised
Panel
1.38”
PU-FIP
Raised
Panel
2”
1/8”
Glass
1.38”
1/4” or
1/2”
Glass
1.38”
1/2 HP
1310
300
256
410
280
520
400
320
320
256
430
430
350
450
430
400
320
3/4 HP
1450
340
256
450
320
540
410
320
320
256
450
450
400
480
460
400
350
1 HP
1650
390
290
510
380
580
410
320
320
256
480
480
420
510
490
400
400
Dealer Imprint Area
AMPERAGE RATING - 60Hz
Hp
115V 1Ø 208V 1Ø 230V 1Ø 208V 3Ø 230V 3Ø 460V 3Ø 575V 3Ø
1/2
10
5
5
3
3
3
2
3/4
11
6
6
3
4
3
2
1
14
7
7
4
4
3
2