Remote Control Operation

A  Press Button on Remote Control .  Garage door will move .
B  Press Button again .  Garage door will stop: 

 

 

 

 

The door automatically stops at the end of the open or    

 

 

close cycle .

C  Press Button again .  Garage door will reverse .

          

                

WARNING:

A moving garage door may cause serious injury or death .
  Keep people clear of opening while door is moving .
  Do not allow children to play with the Remote Controls .
If the Safety Reverse does not work properly:
  Close the door and disconnect the Opener using the  

 

 

Emergency Release Cord .

  Do not use the door Opener, Remote Controls, or  

 

 

Wireless Keypad .

  Refer to the door and door Opener Owner’s Manuals  

 

 

before attempting any repairs .

1 2 3 4

Figure 13 Learn Code Button and Indicator Light

Figure MA-5  Learn Code Button and Indicator Light

1 Button Compact Remote

w/Docking Station

Figure MA-4  Genie Remote Controls

3 Button Compact Remote

w/Docking Station

A  Install two 60 Watt light bulbs (not included) into Light 
Sockets (Figure MA-6):
 

  Rough service, 130 Volt bulbs are recommended .

B  Hold the lens, with the bottom hinges pointing up, against 
the power head metal front cover (Figure MA-7) . 

 

 

    Insert (2) #8-32 x 3/8” Phillips Hex Head Screws    

 

    through the Bottom hinges and into holes provided 

 

    in metal front cover of Power Head (Figure MA-7) .   

 

    Tighten screws . 

 

 

 

 

 

    Flip Lens up and fasten with (2) #8-32 x 3/8” Phillips Pan  

 

    Head Screws where indicated .

Figure MA-7 

Figure MA-6 

i

nStall

 l

iGht

 b

ulbS

 

and

 l

enS

     

 WARNING:

Use the Wall Console included with Opener .  Any 

other wall console can cause the Opener to operate 

unexpectedly and the light to stop working .

To program a Homelink® or Car2U Device:
(This GDO is Homelink® and Car2U compatible)

 

  Follow the Homelink® or Car2U instructions in your car  

 

  owner’s manual .

Содержание DirectLift

Страница 1: ...up to 7 6 tall Doors Extension Kit available for 8 Doors Included Wall Control MUST be installed prior to Operation of this Garage Door Operator Safe T Beam Safety Reverse System Must be Installed an...

Страница 2: ...it yourself repairs Trained service representatives are available Monday Friday 8 00 a m 11 00 p m Eastern Time and on Saturday 10 00 a m to 8 00 p m Eastern Time subject to holidays You may also get...

Страница 3: ...em Places an invisible beam across door opening that reverses the door during down travel to the fully open position if anything passes through beam Safe T Reverse Contact Reversing System Automatical...

Страница 4: ...olid door including door frame must be braced or reinforced before installing Opener C A door opener reinforcement bracket may also be needed to connect garage door to Opener s Door Bracket This Opene...

Страница 5: ...hrough finish material using Lag Screws MOUNTING EXAMPLES Perforated Straps Conduit Perforated Angle Iron Wood Check Ceiling for Grounded Power Source Check Step 6 NOTE Permanent wiring must be instal...

Страница 6: ...store p GER 2 Emergency Release Kit for entry during power failure store p Wood for header ceiling and or door braces store p Masonry fasteners for Safe T Beam Bracket installation store p Safe T Bea...

Страница 7: ...h Figure MA 2 If door is fully open adjustment is finished If door stops but is not fully open a Measure distance between bottom of door top of door opening b Move OPEN Limit Switch that same distance...

Страница 8: ...o delete a Remote Control or Wireless Keypad see To Erase All Receiver Memory C Programming the Remote Controls Programming 1 Accessories To Erase All Remotes from Power Head Memory A Press and hold L...

Страница 9: ...igure MA 5 Learn Code Button and Indicator Light 1 Button Compact Remote w Docking Station Figure MA 4 Genie Remote Controls 3 Button Compact Remote w Docking Station A Install two 60 Watt light bulbs...

Страница 10: ...ther lubricants may damage the Opener FCC AND IC CERTIFIED All devices comply with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful int...

Страница 11: ...tomer Service at 1 800 35 GENIE 5 Check position of Lock Switch on Console Door will only run open 1 Check Safe T Beam System as detailed in the Safe T Beam System Self diagnostic Troubleshooting Char...

Страница 12: ...CONDARY TRANSFORMER SEQUENCER HOUSING Vcc SIGNAL Vcc TRIP STB SYSTEM COMMAND 1 0 1 3 5 Power Head Assembly 1 Parts Identification Item Part Name 1 Power Head Assembly 1 A Cover by Series Model 1 B Fro...

Страница 13: ...8 Emergency Release Knob 1 19 Emergency Release Tag not shown 1 20 Header Bracket 1 21 Door Bracket 1 22 1 4 x 2 Lag Screw 7 23 Straight Door Arm 1 24 Clevis Pin 2 25 Cotter Pin 2 26 Curved Door Arm 1...

Страница 14: ...ulisseau Rallonge de prolongeant la course de l ouvre porte Chain Glide pour une porte de 2 4 m 8 pi de hauteur 60 WATT Enhanced Rough Service Light Bulb Ensures proper equipment compatability Bombill...

Отзывы: