Section 3 In-Flight Procedures
3-23
2nd Ed Aug 2019
S-TEC 3100 Digital and Analog
Figure 3-21:
Emergency Level Mode; Servos Engaged, No AP
3.9.5.
Half Bank (HB) Mode
Half bank (HB) mode is an optional switch/annunciator that limits the 3100's
authority and improves passenger comfort. From HDG or GPSS mode,
press the HB switch to engage HB mode. When HB is engaged, the 3100
limits the commanded bank angle and maximum command bank angle by
50%.
“ON” illuminates when half bank is engaged. “OFF”
illuminates when half bank is disengaged. HB mode
disengages either by pressing the switch again or if the
3100 mode is not HDG or GPSS mode.
Figure 3-22:
HB Mode Switch/Annunciator
NOTE:
HB mode ONLY operates in HDG or GPSS mode.
3.9.6.
Menu (MNU) Button
Press
to modify the display contrast and brightness and to mute
selected audible alerts, as follows:
1) Rotate
(outer knob) CW to increase or CCW to decrease display
contrast.
2) Rotate
(inner knob) CW to increase or CCW to decrease display
and mode button brightness.
3) Push
(inner knob) to toggle mute (indicated by icon). When
muted, all audible alerts are muted except for the disconnect tone.
When unmuted, all configured (loaded) audible alerts and tones sound.