background image

600-

2.16.15

-EE.1

 

Trademarks 

Any brand or product names are trademarks or registered trademarks of their respective holders. 

The Genesis Group Trademark Information 

GenWatch3® is a registered trademark of GenCore Candeo, LTD., a subsidiary of Burks GenCore 
Co., Inc. D.B.A. The Genesis Group and Phil Burks. 

Copyright 

Copyright © 2006-

2020

; Burks GenCore Co., Inc. D.B.A. The Genesis Group and Phil Burks. All 

rights are reserved. No part of this publication or the associated program may be reproduced, 
transmitted, transcribed, in whole or in part, in any form or by any means, whether it is 
mechanical, magnetic, optical, electronic, manual or otherwise, without the prior written consent 
of Burks GenCore Co., Inc. D.B.A: 
The Genesis Group and Phil Burks 
5800 Eagles Nest Blvd 
Tyler, Texas 75703. 
 
Includes technology licensed from Motorola. 

Disclaimer 

The GenWatch3 User’s Manual is printed in the U.S.A. Burks GenCore Co., Inc. D.B.A. The 
Genesis Group and Phil Burks believe that the information included in this manual is correct; 
however, Burks GenCore Co., Inc. D.B.A. The Genesis Group and Phil Burks reserves the right to 
alter, revise and make periodic changes to the manual and its contents. Burks GenCore Co., Inc. 
D.B.A. The Genesis Group does not assume responsibility to notify any person of such revisions 
or changes. While we have taken strides to carefully examine our software and documentation and 
believe that it is reliable, the Genesis Group and Phil Burks assume no responsibility for the use of 
the manual, or GenWatch3 software, nor for any patent infringements or other rights of third 
parties who may use the manual or the GenWatch3 software. Burks GenCore Co., Inc. D.B.A. The 
Genesis Group and Phil Burks make no representations or warranties with respect to the contents 
or fitness for a particular purpose beyond the cost of the software paid by the end-user. 
 
The software contains valuable trade secrets and proprietary information. Unauthorized use of the 
manual or software can result in civil damages and canal prosecution. As an end user, you agree to 
abide by and heed these statements. 

License 

Title to the media on which the program is recorded and to the documentation in support of the 
product is transferred to you, but title to the program, and all subsequent copies of the program, 
despite the form or media in or on license is not a sale of the original or any subsequent copy. You 
assume responsibility for the selection of the program to achieve your intended results, and for the 
installation, use, and results obtained from the program. 
 
Refer to the GenWatch3 Manual Overview for your full license. All license information contained 
on pages 4-7 (Book 600-2.16.15-AA.1) are to be considered as contained herein. 

Support 

Customer satisfaction is our number one priority at Genesis. We are here to provide you with the 
best software possible, and we want to know when you have any questions, concerns or problems 
with GenWatch3 so that we can make it a better product for everyone. 
 
Refer to the 

Troubleshooting & Support

 section of the GenWatch3 Manual Shell (Book 600-

2.16.15-AA.1) for complete support and contact information. 

 

 

Содержание GenWatch3 GW RSP25

Страница 1: ...GenWatch3 GW_RSP25 Module Software Version 2 16 15 Module Book 600 2 16 15 EE 1 4 2 2020...

Страница 2: ...2 600 2 16 15 EE 1...

Страница 3: ...bility for the use of the manual or GenWatch3 software nor for any patent infringements or other rights of third parties who may use the manual or the GenWatch3 software Burks GenCore Co Inc D B A The...

Страница 4: ...ypes KIH 2 0 6 6 Release revisions TDW 2 2 Document reviewed WRK 2 3 Release Revisions REB 2 4 Revision Before Release CWF 2 5 Revisions Before Release CWF 2 6 Revisions Before Release CWF 2 7 Revisio...

Страница 5: ...Power 10 Antenna 11 Placement 11 Connection to the PC 11 Connection Management 11 Programming 12 CHAPTER 2 MANAGING P25 CONNECTIONS 13 P25 CONNECTIONS 13 Adding a Connection 13 Updating a Connection 1...

Страница 6: ...6 600 2 16 15 EE 1 CHAPTER 4 HARDWARE COMPATIBILITY 29 RADIO 29 RADIO INTERFACE 30...

Страница 7: ...and its role in the GenWatch3 solution Managing P25 Connections Describes how to create and manage GW_RSP25 connections Filtering P25 Data Describes how to create a packet filter for a GW_RSP25 conne...

Страница 8: ...8 600 2 16 15 EE 1...

Страница 9: ...ackets are received via serial TCP IP or PPP connection to a digital transceiver or from a remote GW_RSP25 that is setup to rebroadcast CAI packets Each CAI packet source is maintained by a GW_RSP25 c...

Страница 10: ...to connect to the PC If the transceiver is connected via serial port the EFJ Remote Programming Interface RPI can provide a PC connection through the PTT port on the front of the transceiver At least...

Страница 11: ...ly any need to touch the radio there is no need for the radio to be easily accessible Connection to the PC The transceiver is connected to the computer using the USB programming cable provided by Moto...

Страница 12: ...E 1 Programming The XTL series radio must be programmed with only the following features Any additional features may prohibit the radio from functioning as an RF Modem Figure 1 1 Required XTL Series R...

Страница 13: ...he socket the connection is using remains open Connection has not received packets within the last 5 seconds blinks between red and white background for all connections that are not Topaz Conventional...

Страница 14: ...h to delete This will show the properties of this connection 2 Click the Delete button This will result in a confirmation prompt 3 Click Yes Connection Properties Each GW_RSP25 connection contains man...

Страница 15: ...CAI data source For TCP IP Serial and Millennium Serial this is the forwarding TCP IP port on the local machine for all data received Redundancy Position For Millennium connections this allows the con...

Страница 16: ...ection set up as a Serial TCP IP Forwarding TCP IP port on the local machine for all data received from the serial port N A Forwarding TCP IP port on the local machine for all data received from the s...

Страница 17: ...requency column If channel settings are not being decoded frequencies will not be displayed and packets that should contain a frequency will be listed as corrupt In this case you must manually enter t...

Страница 18: ...z for P25 4 0 KHz for NPSPC and 5 0 KHz for interleave analog Channel Band Width RX Values include o 12 500 Hz Generally used by all digital systems o 20 000 Hz o 25 000 Hz o 30 000 Hz Channel Band Wi...

Страница 19: ...epeat the second control channel value in the third and fourth positions o If your system uses only three control channels then repeat the third control channel value in the fourth position Control Ch...

Страница 20: ...F F4 FE Queue Reasons Unit must wait for service call to be available again User or system defined values 128 255 hexadecimal 80 FF The GW_RSP25 GUI allows users to define the same codes for use in Ge...

Страница 21: ...also be imported from a CSV file To import a file click the Import button above the desired list and the Import Codes window appears The title will denote which set of codes you are importing In Figur...

Страница 22: ...the file you wish to open When you open the file the list of reason codes from the file will be displayed in the grid The grid can be used to make sure the list is complete Click Import to import the...

Страница 23: ...rest of the GenWatch3 modules If a filter is set up only packets that reference groups selected in the user s groups or radio IDs that reference this group as their default group are included NOTE De...

Страница 24: ...ction in the Connections list This will show the connection s properties and enable the Options button bottom left of the screen To see the Options button you must be logged in as a user whose role co...

Страница 25: ...overhead messages containing system information for radios By default GenWatch3 throttles these packets down to one per 5 seconds The Disable Filler Packet Throttle option disables the throttling of...

Страница 26: ...Data Files GenWatch3 stores raw data files on your GenWatch3 computer Genesis and Motorola support personnel use these files to help diagnose control channel decode issues you may have with GenWatch3...

Страница 27: ...s archive operation to another drive For instructions on how to change the raw data file directory see the GenWatch3 Config Files section of Chapter 3 GenWatch3 Service in the GenWatch3 Core Manual Wa...

Страница 28: ...28 600 2 16 15 EE 1...

Страница 29: ...Number 242 5377 XXX The GW_RSP25 module is compatible with the following transceivers via the Millennium interface XTL 2500 o Manufacturer Motorola o Model Number Varies based on programming o Firmwa...

Страница 30: ...nnect the radio s to the PC Connecting the radio to the computer s serial port can be accomplished with the following Remote Programming Interface o Manufacturer EF Johnson o Part Number 023 5300 000...

Отзывы: