Timeout Between Decodes, Same Symbol
Parameter # 89h
Use this option in
Presentation Mode
or
Continuous Bar Code Read
to prevent multiple reads of a symbol
left in the decoder’s field of view. The timeout begins when you remove the symbol from the field of view.
To select the timeout between decodes for the same symbol, available in 0.1 second increments from 0.0 to
9.9 seconds, scan the bar code below, then scan two numeric bar codes from
that correspond to the desired interval. The default interval is 0.6 seconds.
Timeout Between Decodes, Different Symbols
Parameter # 90h
Use this option in
Presentation Mode
or
Continuous Bar Code Read
to control the time the decoder is
inactive between decoding different symbols. It is programmable in 0.1 second increments from 0.1 to 9.9
seconds. The default is 0.2 seconds.
To select the timeout between decodes for different symbols, scan the bar code below, then scan two numeric
bar codes from
that correspond to the desired interval, in 0.1 second
increments.
NOTE
The
Timeout Between Decodes, Same Symbol
value must be greater than the
value.
Timeout Between Decodes, Same Symbol
NOTE
The
Timeout Between Decodes, Different Symbols
value cannot be greater than or equal to the
Timeout Between Decodes, Same Symbol
or the
Decode Session Timeout on page
value.
Timeout Between Decodes, Different Symbols
G S -R 5000 -51C Barcode Configuration Document