GeneralAire Water Savor Скачать руководство пользователя страница 2

V.  Customized Water Savor™ Settings

 (to ensure maximum water savings):  

1.  Start by using the recommended setting for your humidifi er.  If your humidifi er is not on a Table below, start at setting #6 (minimum savings).  
2.  Maintain the recommended setting for 3 days. This allows time for humidity to migrate and stabilize throughout the home.
3.  After 3 days at the recommended setting, record humidity levels by using a humidity gage, or simply determine how the humidity feels in 

the home. If humidity has not dropped, move on to step 4 to save even more water.

4.  Switch the setting on the dip switch to one number less than the current setting.  For example; if your current 

setting is at #3, turn #3 setting to OFF and turn setting #2 ON (see Figure 4, to right).

5.  Maintain the new setting for 3 days, again to allow humidity time to absorb and migrate throughout the home.
6.  After 3 days at the new setting, again record what the humidity is in your home by using a humidity gage or 

judging how the humidity feels in the home.

7.  If the humidity dropped, change back to the previous setting.  This would indicate your humidifi er’s optimum water saving capabilities.
8.  If the humidity did not drop, repeat steps 3 & 4, until you fi nd the optimum setting.

OFF

Figure 4

ON

OFF OFF OFF OFF

FORM NO. WSC_06_REV_B - Engineering / Files / Released / Manuals

(10-2015; JPF)  H: Indesign Work / Installation Manual / WaterSavor

2

WSC WaterSavor Controller Installation Manual

Cut Out to Mail

Product Information

Serial Number:  __________________________________________________

Model:__________________________________________________________

Installation Date Month:    ___________Day:  _________Year:  __________

Owner Information

Name:  _________________________________________________________

Address:  _______________________________________________________

Address 2:  _____________________________________________________

City:  _______________________State:  _________Zip Code:  __________

Phone:  ________________________________________________________

Email:  _________________________________________________________

Contractor Information

Contractor Name: ________________________________________________

Address: ________________________________________________________

Address 2: ______________________________________________________

City:  ______________________State:  _________Zip Code:  ____________

Contractor Phone:  _______________________________________________

Contractor Email:  ________________________________________________

Warranty Registration

Register Online  

www.GeneralAire.com / Support Center
www.cgfproducts.com/Warranty Registration

Or Mail

USA CUSTOMERS, MAIL TO:

General Filters, Inc
Attn: Warranty Dept.
43800 Grand River Ave.
Novi, MI 48375
www.generalfi lters.com

CANADIAN CUSTOMERS, MAIL TO:

Canadian General Filters, Ltd.
Attn: Warranty Dept.
400 Midwest Rd.
Toronto, ON M1P3A9 Canada
www.cgfproducts.com

Keep a copy for your records!

Warranty Registration - Keep a Copy For Your Records

VI.  Warranty

Your WaterSavor™ Controller is warranted to the consumer against defects in materials and workmanship for a period of one year from date of 
installation. Defective units will be replaced without charge except for removal, reinstallation and transportation costs.  To obtain a replacement 
unit under this limited warranty, the consumer must send the defective unit to the manufacturer.  The manufacturer assumes no liability in 
connection with the installation or use of this product, except as stated in this limited warranty.  The manufacturer will in no event be liable for 
incidental or consequential damages.

Model

Hot 

Cold 

Setting

GeneralAire

SL16

5

3

1042 / 1042WSC

5

3

1099LHS

5

4

570 / 570WSC

5

3

900 / 900WSC

5

3

RECOMMENDED DIP SWITCH SETTINGS

Model  

Hot 

Cold 

Setting

Honeywell

HE220

5

4

HE240

5

4

HE260

5

4

HE265

5

4

HE280

5

4

Model

Hot 

Cold 

Setting

Aprilaire 
White Rogers

AA 500

5

4

AA 600

5

4

AA 700

5

4

HFT2100

5

4

HFT2700

5

4

Model 

Hot 

Cold 

Setting

Goodman
Desert Springs

HE12A / HE12M

5

3

HE17A / HE17M

5

3

HE12MB

5

3

HE17MB

5

3

DS-PFT

6

5

Model

Hot 

Cold 

Setting

Skuttle
Lennox

SK 2000

5

4

SK 2001

5

4

SK 2002

5

4

HCWB3-12

5

4

HCWB3-17

5

4

Manufacturers of Whole House Residential Indoor Air Quality Products.