1.  INTRODUCTION

The GFX50 includes Indoor and Outdoor Temperature Sensors, Indoor Humidity Sensor and Control Unit.

2.  INSTALLATION

2.1  Assembly

Open the product by detaching the front from the mounting base, as 
shown in Fig. 2.a:

Remove  the  locking tab and screw from the the base underside. 

Slide the plastic tab back as shown to remove it from the base. 

upwards.

in the middle on the bottom of the case while lifting the front panel 

clock

set

mode

an

h ld

resume

aria

cloc

k

set

mode

fan

hold

resume

Fig. 2.a

Fasten the humidistat base to the wall using the screws supplied. 

Access the terminal block by squeezing the clips on the terminal cover.

Important:

  Make   sure   all   connections  are   complete  before 

 

 

 

 

 

 

 

 

 

 

Note:

  For  the  purposes  of  electrical  safety  (EN60730-1),  once  the 

controller has been installed, replace the plastic locking tab in the  

humidistat base.

Accessories and dipswitches (Fig. 2.b)

Connector

Function

J1

- Supervisor serial connection using code IROPZ48500.
- Key connector for copying the parameters. The serial 
connection, if used, must be momentarily disconnected..

J2

Not Used.

FLAT 
Front-rear

polarity

Tab. 2.a

J2

 = sonda esterna T+H - ADCF006500

J1

per opzione 

seriale o chiave 
di programmazione

FLAT Front-Rear

Dip-switches

Fig. 2.b

2.2 Dimensions

For installation, see the drilling template included in the packaging.

5 5/16” (135mm)

1 7/16” (36mm)

3 3/8”

(86mm)

Fig. 2.c

4

Make the necessary connections and run the wires through the hole 
in the middle of the base.  Separate the sensor wires from the control 
wires.  The diagrams are shown in Section 2.3.

Содержание GFX50

Страница 1: ...GFX50 Residential Humidistat User manual Revision 1 1...

Страница 2: ...vironments that comply with the temperature and humidity limits do not install the device in particularly hot environments Too high temperatures may reduce the life of electronic devices damage them a...

Страница 3: ...buttons 6 3 2 Description of the buttons 6 4 CONFIGURATIONS 7 4 1 Setting the Dip Switches 7 4 2 Setting Parameters 7 4 3 Auto Humidity Control 7 4 4 Sensor Calibration 8 4 3 Additional Functions 8 5...

Страница 4: ...nections are complete before Note For the purposes of electrical safety EN60730 1 once the controller has been installed replace the plastic locking tab in the humidistat base Accessories and dipswitc...

Страница 5: ...connectioins See Fig 2 b Note the factory See Elite Steam Manual GFX50 ON D P 1 2 3 4 DIPSWITCHSETTNGS ON OFF OFF ON Fig 2 c GFX50 terminal 1 and 2 See Fig 3 x 2 3 4 Placement of Remote Outdoor Tempe...

Страница 6: ...ttons to increase or decrease the time Press a second time to exit and return to the main menu If sleep mode is already active pressing the button shows the time remaining on the timer E g if in Night...

Страница 7: ...When the time bands are set the CLOCK symbol is shown on the display PARAMETERS check set the other parameters dIF dS1 based on the mode used Note Note If AUTO humidity mode is enabled the humidity s...

Страница 8: ...mer This value can be changed at any time To exit the menu press the NIGHT button again 5 FUNCTIONS 5 1 H humidity control This type of control is used to send a start signal to a humidifier or dehumi...

Страница 9: ...re OFF 1H to 7H OFF 7 ALARMS AND SIGNALS Note three dashes are displayed 7 1 Table of alarms code on display ect EE system memory error manual stops all outputs Eth temperature humidity sensor fault a...

Страница 10: ...86x36mm Tab 5 a 8 2 Wiring n o i s r e v d e t a l o s i n o N t u p n i l a t i g i D direct connection of the voltage free contact contact closing current 3 to 5 mA Isolated version with external po...

Страница 11: ...Note...

Страница 12: ...NERAL FILTERS INC 43800 GRAND RIVER AVE NOVI MICHIGAN 43875 1115 WWW GENERALAIRE COM CANADIAN GENERAL FILTERS LTD 400 MIDWEST POAD TORONTO ONTARIO M1P3A9 WWW CGFPRODUCTS COM Agency Form GFX50 05 Rev 1...

Отзывы: