background image

That is how you should stop data logging if you plan to initiate

another logging session later without uploading logged data

to your computer in the interim. If you allow logging to

continue and you do not upload your data to your computer

soon, you risk filling up the HT08

08

08

’s memory.  

A simpler and safer way to stop data logging is to plug the

HT  into your computer’s USB port immediately after

completing a logging session and then use the ELUSB

software to stop logging.
Each time you plug the HT  into the USB port, the window

shown in Fig. 2 will appear. When you plug in the unit, it

makes no difference whether it is still logging; the procedure

for uploading (importing) data logs is identical. Just click on

the middle selection—

Stop the USB Data Logger and

download data

—to instantly execute both functions. The

data will be imported as a .txt file. A “Save As” window will

appear, asking you to identify where you want the file to be

stored and what you want to name it.

VIEWING, PRINTING AND EXPORTING 

DATA LOGS

Immediately after you close the “Save As” window by 

clicking on 

Save

, the uploaded data log will automatically be

displayed as a set of curves representing all loggable values.

Fig. 4 is a typical example. The initial display includes all

parameters, including dew point and GPP or g/kg (which the

software automatically calculates) and alarm setpoints that you

may have entered during Setup. To remove any parameter or

horizontal and vertical grid lines from the overall plot, uncheck

its box at right.

14

Содержание HT08

Страница 1: ...USB RH TEMPERATURE GPP MINI DATA LOGGER USER S MANUAL HT08 Please read this manual carefully and thoroughly before using this product HT08 Manual RR FINAL_061914_awb...

Страница 2: ...7 12 Installing Replacing the Battery 7 Install Software and Drivers 7 9 Configure the Unit 9 12 Operating Instructions 13 16 Deploy the Unit 13 14 Stop Logging and Import Logs 14 Viewing Printing and...

Страница 3: ...a job s drying phase Data logging can be started or stopped by pushing a button on the unit eliminating the need to bring a laptop to the job site After a data log has been captured and stored it can...

Страница 4: ...uring Alerts provided by the low humidity alarm function of the HT can mitigate the risk of damaging high voltage static discharges KEY FEATURES One button starts stops data logging without a PC Plug...

Страница 5: ...R PACK The HT08 comes in a blister pack that also contains One 1 2 AA battery Replacement batteries Part No BA10 are available from General www generaltools com A disc with software drivers for Window...

Страница 6: ...rself with their names and functions before moving on to the Setup Instructions A Temperature and humidity sensor window B Battery compartment latch is on rear of unit C Two color green and red LEDs i...

Страница 7: ...ery each of the two LEDs will flash red once and then green once Note If the battery is removed from a unit before it has been set up from software or while it is recording the unit must be reconfigur...

Страница 8: ...t to install the software elsewhere click Browse and choose another location Within each window after selecting either the default location or another location click Next N to continue 7 When the Prep...

Страница 9: ...le USB jack does not have enough vertical clearance to accommodate the HT08 T08 T08 without mechanically stressing its USB plug do not plug the HT directly into the jack You do not want the plug of th...

Страница 10: ...o appear Click Yes to stop recording and import all data recorded to that point in time Click No to continue to Setup without importing recorded data meaning it will be lost Click Cancel to go back an...

Страница 11: ...and low temperature alarm setpoints High and low humidity alarm setpoints To begin click on Set up the USB Data Logger in the window shown in the figure above Doing so will cause the following window...

Страница 12: ...e meter to log unless you use it to log data for months rather than weeks or days Be aware that if you do manage to fill up the HT s memory by logging for a very long time at a very short sampling tim...

Страница 13: ...dow Fig 1 Callout A is not covered The humidity and temperature values at the unit s location are representative of the room The HT with its protective cap on can be deployed either by laying it on a...

Страница 14: ...uploading importing data logs is identical Just click on the middle selection Stop the USB Data Logger and download data to instantly execute both functions The data will be imported as a txt file A...

Страница 15: ...ific period of time scale up and down the curves by dragging the slider at the bottom of the window to the left and right Hovering the cursor over a particular point of the curve displays all data rel...

Страница 16: ...unit is ready to log data a quick press of the MODE button will cause both LEDs to flash green once If the HT08needs to be configured the two LEDs will alternately flash red and green twice If a quick...

Страница 17: ...t Accuracy 3 from 20 to 80 RH 3 5 elsewhere RH Measurement Resolution 0 1 and Repeatability Internal Storage Capacity 16 300 pairs of RH Temp readings Temperature Response Time 5 30 seconds Humidity R...

Страница 18: ...repair or replace this instrument if after examination the company determines it to be defective in material or workmanship This warranty does not apply to damages that General determines to be from...

Страница 19: ...ntact our Customer Service to obtain an RGA Return Goods Authorization number before forwarding the unit via prepaid freight to the attention of our Service Center at this address General Tools Instru...

Страница 20: ...2 431 6100 FAX 212 431 6499 TOLL FREE 800 697 8665 e mail sales generaltools com www generaltools com HT08 User s Manual Specifications subject to change without notice 2014 GENERAL TOOLS INSTRUMENTS...

Отзывы: