INSTALATION
P/N GENSLICERMAN
RevA 10-2011
8
GSE-109-110-112 SLICER
1. Place the unit on a sturdy, level table or other
solid work surface.
CAUTION
WHEN USING CHEMICAL CLEANERS, BE SURE
THEY ARE SAFE TO USE ON CAST ALUMINUM
SURFACES. SOME CLEANERS WILL TARNISH AND
PIT THE SURFACE
WARNING
FAILURE TO FOLLOW ESTABLISHED OPERATING
PROCEDURES CAN BE HAZZARDOUS TO YOUR
HEALTH. FAILURE TO COMPLY CAN RESULT IN
ELETRICAL SHOCK, SERIOUS INJURY OR DEATH.
When placing the unit into service, pay attention to the
following guidelines:
• Assure the appliance is placed upon a solid, sta-
ble platform.
• Do not block or cover any openings on your GSE
slicer.
• Assure the chosen installation location is solid
and level.
• Do not use extention cords
• Install the slicer in a well-lighted area with ade-
quate unobstructed space to allow free move-
ment by the operator..
1. Carefully open the box. It should contain the fol-
lowing:
• GSE-109, GSE-110 or GSE-112 Slicer,
• Warranty Packet,
• Operation Manual,
• Plexi-Gard
2. Remove information packet.
3. Remove all packing materials and protective cov-
erings from the slicer.
3. Install Plexi-Gard
NOTE: Do not use a dripping wet cloth. Wring out
before use.
4. Wash all removable parts in soap and water.
Rinse with clean hot water and allow to air dry.
5. Wipe all surfaces of the unit with a hot damp
cloth and a mild detergent.
6. Re-install all removed parts.
• Do not allow the cord to hang over edge of table
or counter.
• Before attaching any accessories or attachments
to the slicer, refer to the operating instructions.
• Tighten the black thumb screw to secure the knife
sharpener located at the top of the slicer.
• Tighten the black thumb screw to secure the knife
cover, located on the rear of the slicer directly
behind the knife
• Tighten the large black hand screw locate on the
front slide to secure the product pusher arm.
• Turn the depth gage to assure free movement of
the product tray.
2. Ensure that the line voltage corresponds to the
stated voltage on the mixer specification label
and power cord warning tag.
3. Connect the unit to the power supply.
NOTE: Do not use extension cords with this appli-
ance.
NOTE: Do not conncet without an approved earth
ground.
UNPACKING
EQUIPMENT SETUP
(CONTINUED)
EQUIPMENT SETUP
ELECTRICAL
Содержание GSE-109
Страница 1: ......
Страница 14: ...13 P N GENSLICERMAN RevA 10 2011 GEM 110 120 130 MIXER REPLACEMENT PARTS GSE 110...
Страница 15: ...GSE 109 110 112 SLICER 14 P N GENSLICERMAN RevA 10 2011 REPLACEMENT PARTS GSE 110...
Страница 16: ...GSE 109 110 112 SLICER 15 P N GENSLICERMAN RevA 10 2011 REPLACEMENT PARTS GSE 110...
Страница 17: ...GSE 109 110 112 SLICER 16 P N GENSLICERMAN RevA 10 2011 REPLACEMENT PARTS GSE 112...
Страница 18: ...GSE 109 110 112 SLICER 17 P N GENSLICERMAN RevA 10 2011 REPLACEMENT PARTS GSE 112...
Страница 19: ...GSE 109 110 112 SLICER 18 P N GENSLICERMAN RevA 10 2011 NOTES...