AF500 AIR-SCRUB-R

®

 Portable HEPA Air Filter 

FORM GOM24101701US, VERSION 1.0 

 

 

 

 

 

       

English-EN

 

 

5

 

 

 
DETERMINATION OF POTENTIAL ABOVE SURFACE HAZARDS IN 
PROPOSED JOBSITE LOCATION(S) 

 
Normal AIR-SCRUB-R use is on a level surface. Avoid other surface conditions 
which can be dangerous. Special care must be exercised on slippery, and/or 
difficult/uneven surfaces. Watch for surface irregularities or drop offs to lower 
floor levels. Identify any objects that could puncture ducting. Check for large, 
heavy debris that could be pulled into the AIR-SCRUB-R. Remove any trip/fall 
hazard BEFORE operating AIR-SCRUB-R. Check for such hazards as water, 
flammable/combustible/toxic liquids, gases, vapors, dusts fibers or filings. 
 

OPERATIONAL HAZARDS 

 
1. 

The air filtering process can produce sparks, dusts and other foreign 
particle contamination that can result in fire and/or explosion depending 
on existing jobsite conditions.  
 

2. 

Dust, dirt and debris can contain asbestos and other chemicals that are 
known to cause physical harm and/or affect the environment.  

 

3. 

Excessive water, and/or other conductive materials on work surface can 
result in electrocution of operator and/or other personnel. 

 

4. 

When used in negative air ducting applications, to prevent airborne 
particulates from escaping space, exhausting too much air from a space 
with open combustion devices (e.g. furnace, fireplace or water heater) 
can cause those devices to backdraft and contaminate space with 
potentially fatal gases.  

 

IMPORTANT:

 Only professionals with appropriate training should set up 

negative pressure containment areas.    

 

Preventive Measures: 

 

Operator must maintain physical and mental alertness. Be prepared for 
unexpected dirt and/or debris coming in contact or entering                  
AIR-SCRUB-R. DO NOT allow inlet to become blocked or place object in 
inlet and/or outlet opening. Operator must be capable of sensing level of   
AIR-SCRUB-R control operator has.  

 

 

DO NOT operate AIR-SCRUB-R in areas where flammable or 
combustible liquids, gases, vapors, dust, fibers or filings may be present. 
DO NOT discharge flammable liquids or chemicals through                  
AIR-SCRUB-R.  

 

 

DO NOT place AIR-SCRUB-R in standing water or operate when raining. 
DO NOT allow water inside AIR-SCRUB-R or motor. If motor/             
AIR-SCRUB-R becomes wet for any reason, dry thoroughly BEFORE 
operating. Remove water and/or conductive materials by industry-
approved and/or accepted practice BEFORE operating AIR-SCRUB-R. 
Determine AIR-SCRUB-R is properly grounded and power cords are free 
of cuts, abrasions and/or exposed cable strands. 

 

 

For negative air ducting applications, AIR-SCRUB-R must be used in one 
of three ways: 

a) 

As filtering unit only.  Exhaust no air from space preventing 
negative pressure or back drafting. 
 

b) 

Exhaust very limited amount of air preventing backdraft. Open 
combustion devices must be thoroughly checked to guarantee 
devices do not backdraft while AIR-SCRUB-R is operating. 

c) 

Route outlet duct from AIR-SCRUB-R to room with open 
combustion devices to create positive pressure with filtered 
air. Open combustion devices must be thoroughly checked to 
guarantee devices do not backdraft while AIR-SCRUB-R is 
operating. 

6  MACHINE SPECIFICATIONS 

 
                      FIGURE 1 
          

 

AF500 SPECIFICATIONS  

AIR FLOW TYPE 

Radial 

HOUSING 

High density, UV resistant polyethylene 

FAN 

Aluminum blades and hub 

ELECTRIC MOTOR 

1/4 HP, 115 VAC, 60 Hz, variable speed 

POWER CORD 

16-3 SJT X 25 ft. (8 M) length 

VOLUME FLOW 

Variable up to 500 CFM (14.2 CMM) 

PRE-FILTER 

30% efficient @ 0.5 microns, 18 x 18 x 1 inch 
(457.2 x 457.2 x 25.4 mm) pleated media,      
H-13 classification 

HEPA SECONDARY 
FILTER 

99.7% efficient @ 0.3 microns, 18, 18 x 2.5 
inch (457.2 x 457.2 x 63.5 mm) pleated HEPA 

NOMINAL INLET 
DIAMETER 

16 inches (406.4 mm) 

NOMINAL OUTLET 
CONFIGURATION 

10 inches (254 mm) lay flat 

WIDTH 

14 inches (355.6 mm) 

LENGTH 

22 inches (558.8 mm) 

HEIGHT 

24 inches (609.6 mm) 

WEIGHT 

33 lbs (15 Kg) 

OPERATING 
ENVIRONMENTS 

Non-hazardous type locations.  

REQUIRED NUMBER 
OF OPERATORS 

 

7  STANDARD PRODUCT & ACCESSORIES 

Refer to FIGURE 1 for overview description of standard components included 
in machine. Included in shipment for AIR-SCRUB-R should be the following: 

1 each, Model AF500 
1 each, operator manual 
1 each, safety and operational DVD 
1 each, final inspection form 

 
ACCESSORIES 

 

Part # 

Description 

Weight 
(in lbs) 

FD1625 

DUC-PAC 16 inch 
(400 mm) diameter x 
25 ft. (7.6 M) long 
ducting.   

39.9 

  WARNING      

 

 

BEFORE attempting to ventilate an area, identify/mark all potential 
subsurface hazards in proposed ventilation locations(s). Potential 
subsurface hazards may include, but may not be limited to the 
following: 
 

1. 

Buried debris, rotted timbers or wood planking. 

2. 

Buried pressurized pipelines (e.g. natural gas, propane, 
etc.) 

3. 

Buried electrical cables. 

4. 

Water, flammable/combustible/toxic liquids, gases, 
vapors, dusts, fibers, or filings.  

 

Содержание AIR-SCRUB-R AF500

Страница 1: ...on or when servicing product Before operation read and comprehend operator manual content Customer Service 001 507 451 5510 Customer Service Telefax 001 507 451 5511 Note There is no charge for Custom...

Страница 2: ...tering negative pressure job requirements The basic concept is proven and well accepted within the associated marketplaces Use of an AIR SCRUB R requires strenuous work activity when moving the equipm...

Страница 3: ...NFORMATION VIDEO TAPE _________________________________ Operator ______________________________ Owner Instructor __________ Date _________________________________ Operator ____________________________...

Страница 4: ...designate the degree or level of hazard seriousness Other safety symbols may be used to represent the type of hazard in combination with general warning symbol in highlighted boxes or individually DAN...

Страница 5: ...3 Develop a consistent exercise routine 4 Maintain good posture while walking or sitting 5 Watch how you twist bend your body while bending to prevent injury Twisting bending incorrectly can exert to...

Страница 6: ...EFORE operating Remove water and or conductive materials by industry approved and or accepted practice BEFORE operating AIR SCRUB R Determine AIR SCRUB R is properly grounded and power cords are free...

Страница 7: ...bag end containing strap and buckle Slip duct dust cuff over AIR SCRUB R inlet flange Using fingers tighten cinch strap to secure 3 Loosen draw string on opposite end of duct storage bag and extend du...

Страница 8: ...ST button on GFCI receptacle RESET button should pop out and small LED light on face of receptacle will not be lit While still connected to power press RESET button until noticeable click is heard Sma...

Страница 9: ...IMPORTANT Motor will restart if power is lost then comes back on There is no automatic shut off feature on the AIR SCRUB R 11 Monitor change filter indicator light throughout operation When light indi...

Страница 10: ...cal becomes damaged and or unreadable replace 10 Inspect primary ducting for dirt and oil build up on inside and outside surfaces Clean as necessary with mild soap and water for improved air flow perf...

Страница 11: ...w at AIR SCRUB R outlet If airflow is unacceptable and or change filter light remains lit proceed to next step NOTE To substitute a standard 30 pre filter with an activated carbon filter follow STEPS...

Страница 12: ...s failed Replace unit non serviceable item Housing damaged presses against fan blade Replace unit non serviceable item Roll pin locking fan to motor shaft is faulty Replace unit non serviceable item U...

Страница 13: ...AF500 AIR SCRUB R Portable HEPA Air Filter FORM GOM24101701US VERSION 1 0 English EN 12 THIS PAGE INTENTIONALLY LEFT BLANK...