To show the time portion of the system clock setting, press the 

UNIT

or 

STORE/ENTER

button with the date value on-screen. In the lower

screen shot at right, the time shown is 19:18:12 (7:18:12 p.m.)

Next, press the 

UP>

button to shift the 

icon one position to the

right, above 

INT

Doing so will shift the secondary display to the value of the auto
recording time interval 

INT

. Press the 

UP>

button once more to display the recording time length

TML

, and then again to display the working group 

JOB

number.

To stop displaying data logging settings and return to showing real-time readings, press the 

HOLD

button. 

Changing Data Logging Settings

To reset the system clock

, begin by pressing the 

LOG/SET

button and making sure the 

mode

selector is positioned over 

TM

.

With 

DATA

showing on-screen, press the 

LOG/SET

button. This will cause the Year field at the left

side of the LCD to begin flashing. To increment the Year value, press the 

UNIT

button. To

decrement the Year value, press the 

STORE/ENTER

button.

When the Year value is correct, press the 

LOG/SET

button to save the setting and advance to the

Month field, which should now be flashing. Use the 

UNIT

or 

STORE/ENTER

button to correct the

Month setting. Then press the 

LOG/SET

button to save the setting and advance to the Day field.

Again use the 

UNIT

or 

STORE/ENTER

button to correct the Day value and press the 

LOG/SET

button to save the setting.

Pressing the 

LOG/SET

button with the Day value of the system clock flashing switches the

secondary display to show the current time. As you did with the Date, use the 

UNIT

or

STORE/ENTER

button to correct each of the Hour, Minutes and Seconds values in turn. Once you

have finished setting the system clock, press the 

LOG/SET

button to save the setting. Complete

the process by pressing the

HOLD

button to return to displaying real-time readings.

To change the value of the data logging time interval INT

:

Press the 

LOG/SET

button to enter viewing and setting mode

Move the 

mode selector over 

INT

.

Press the 

LOG/SET

button again. This will cause the two digits on the secondary display to

flash.

Содержание RHMG700DL

Страница 1: ...14 IN 1 DATA LOGGING THERMO HYGROMETER WITH PIN PINLESS MOISTURE METER USER S MANUAL RHMG700DL Please read this manual carefully and thoroughly before using this product...

Страница 2: ...urchasing General Tools Instruments General s RHMG700DL 14 in 1 Data Logging Thermo Hygrometer with Pin Pinless Moisture Meter Please read this user s manual carefully and thoroughly before using the...

Страница 3: ...s capacitance which the meter measures by gauging its effect on an electric field that the meter generates each time it is operated in internal moisture mode In internal moisture mode the meter exploi...

Страница 4: ...using pinless sensor 6 absolute moisture level using included pin type probe 7 dew point 8 wet bulb temperature 9 surface temperature requires optional K type thermocouple probe 10 condensation temper...

Страница 5: ...e Internal or MI measurements In memory and data logging modes used to clear stored readings and data H UNIT button In measurement mode each press toggles between Imperial and metric measurement units...

Страница 6: ...logging length setting indicator Data log working group setting indicator Clear data logging setting indicator Default setting indicator Alarm limit indicators Data logging indicator Zero indicator P...

Страница 7: ...midity temperature sensor To power off the meter press and hold the HOLD button for at least 2 seconds The shutdown will be announced by two short beeps After powering off the meter replace the sensor...

Страница 8: ...lluminates whenever any button is pressed It will remain on for 30 seconds and then extinguish to extend battery life Holding readings Briefly pressing the HOLD button freezes both the primary and sec...

Страница 9: ...isplayed returns the indicator to the record number of the last pair of readings stored To exit Recall mode and resume making real time measurements press the STORE ENTER button To erase all stored re...

Страница 10: ...hange your next step must be to press the STORE ENTER button Doing so saves the value shown on the primary readout as the selected parameter s new LOW setpoint It also causes LOW to disappear and retu...

Страница 11: ...ale they exist only to provide an analog way to quickly track changes in relative moisture levels To use the included pin type probe to measure the moisture level of a material 1 Use the UP or DN butt...

Страница 12: ...of 75 Two salts of this type are available from General the HR33LJ 33 MgCl Calibration Salt and the HR75LJ 75 NaCl Calibration Salt Depending on the size and shape of the calibration salt bottle that...

Страница 13: ...decrement the Year value press the STORE ENTER button When the Year value is correct press the LOG SET button to save the setting and advance to the Month field which should now be flashing Use the UN...

Страница 14: ...button to increment the TML value or the STORE ENTER button to decrement it The default value of TML is 15 minutes The minimum possible value is 1 minute and the maximum possible value is 30 days It s...

Страница 15: ...mini disc supplied with the RHMG700DL is to display data logs captured and stored by the meter The program s secondary function is to make it easy to set the meter s system clock and to change its da...

Страница 16: ...d parameters you wish to display At the upper left side of the screen are circles you can check to select the units of key measurement parameters Below these circles are six boxes for manually enterin...

Страница 17: ...9 Pinless Moisture Measurement Depth 0 75 in 19mm Dew Point Range 76 to 140 F 60 to 60 C Atmospheric Pressure Range 30 to 120 kPA Vapor Pressure Range 0 to 20 0 kPA Sampling Rate 2X sec Memory Capaci...

Страница 18: ...if after examination the company determines it to be defective in material or workmanship The warranty period begins on the date of purchase You are encouraged to register your product online General...

Страница 19: ...ntact our Customer Service to obtain an RGA Return Goods Authorization number before forwarding the unit via prepaid freight to the attention of our Service Center at this address General Tools Instru...

Страница 20: ...20...

Страница 21: ...1 6100 FAX 212 431 6499 TOLL FREE 800 697 8665 e mail sales generaltools com www generaltools com RHMG700DL User s Manual Specifications subject to change without notice 2014 GENERAL TOOLS INSTRUMENTS...

Отзывы: