General Pipe Cleaners Gen-Eye Micro-Scope2 Скачать руководство пользователя страница 8

Gen-Eye Micro-Scope2

®

 Video Pipe Inspection/Location System  

DO NOT BEND THE PROBE ROD TIP AT AN    

ANGLE GREATER THAN 30 DEGREES!  

DO NOT BEND THE PROBE ROD WHERE IT 

CONNECTS TO THE DISPLAY UNIT! 

SKIDS 

It is highly recommended that you use a skid at all times to protect the 
camera head from abrasion in the pipe. Skids lift the camera off the 
bottom  of  the  pipe  and  center  it  in  the  line  for  a  better  view  and  to 
allow the camera to glide more easily though the line.  
Two  skids  are  sold  separately  for  the  Micro-Scope2,  a  ball 
skid (GM-28MM)  and a brush skid (GM-28MMSB).  
To attach the skid, slide it over the front of the camera 

head, with the lip of the skid at the front. Make sure the 
camera body is clean and the set screws are tightened 
only  until  they  touch  the  camera  body.  Do  not  over 

tighten,  as  you  may  damage  the  camera  housing.  The 
nylon brushes of the brush skid may be trimmed down to 
fit the pipe opening.  

5.  Make sure you have established live image on the monitor prior 

to  recording.  Use  the  ZOOM  IN  or  ZOOM  OUT  buttons  as  re-
quired to capture the image needed. You can also use the MIR-
ROR  IMAGE  &  ROTATE  button  to  flip  or  rotate  the  image  as 
needed. 

6.  Slide the camera into the line. Be sure that the push rod is rated 

for the size pipe you are inspecting. Be careful not to force the 

camera around tight bends. 

If you see an obstruction, stop. Do 

not attempt to clear the pipe by using the camera head as a 
battering ram. 

Always use the proper tool for the job. 

7.  Once the camera is in the pipe, adjust the lights to a level which 

produces the best picture with the least amount of light. This will 
vary  depending  on  pipe  conditions.  In  some  cases  white  or 

lighter colored objects may cause the picture to “flare” or “wash 
out”.  If  this  happens,  simply  adjust  the  light  level  until  a  good 

picture is achieved. 

8.  Push  the  camera  slowly  and  carefully  during  the  inspection  - 

taking  note  of  the  pipe  condition  for  possible  hazards  that  may 
entangle or damage the camera on entry or retrieval. 

9.  When negotiating a corner, care should be taken not to butt the 

nose of the camera against the sidewall with any force. It would 

be better to let the camera “work” its way around the corner.

 

10.  Should  resistance  become  extreme,  or  the  camera  gets  entan-

gled or stuck, slowly push and pull back and forth to free it. Do 
not force the camera through a collapsed pipe. 

11.  To record video or snapshots of inspection, see page 7. 
12.  When  inspection  is  complete,  retract  Push-Rod  from  drain  and 

secure in the reel. 

Tip: It's often helpful to have a small stream of water running in the 

line to clean the Push-

Rod and Camera Head while it’s still in the 

drain line. 

NOTE: The micro push rod is designed to be used in 1-1/2” to 3” 
lines ONLY. Do not use it in larger or smaller lines, or you may 
damage the push rod. 

INSPECTION CAMERA OPERATION 

CAMERA REEL

 

Reel Type

 

Pipe Sizes

 

Lengths

 

Available

 

Micro-Reel

 

1-

1/2” to 3”

 

(38 to 100mm)

 

100 ft.

 

(30 m)

 

NOTE: The micro push rod is designed to be used in 1-1/2” to 3” 

lines ONLY. Do not use it in larger or smaller lines, or you may 
damage the push rod. 

1.  Connect camera cable and power cord. 
2.  Insert USB Flash Drive (Part #184490) 

into  port  of  the  left  side  of  the        
Command Module. 

3.  Press and hold POWER button. Start up screen will appear in a 

few seconds. 

4.  When the image from the camera appears on the screen, begin 

the inspection. To adjust the brightness of the camera lights, use 
the  LED  Dimmer  Control  located  on  the  face  of  the  Command 
Module. 

Содержание Gen-Eye Micro-Scope2

Страница 1: ...ars of trouble free profitable service However no machine is better than its op erator Read understand and follow all safety warnings and instructions provided with the product Failure to follow the warnings and instructions may result in electric shock and or serious injury Save all warnings and instructions for future reference SAVE THESE INSTRUCTIONS ...

Страница 2: ...situation Use a UL approved tester to determine if the outlet is safe Do not operate power tools in explosive atmospheres such as in the presence of flamma ble liquids gases or dust Power tools create sparks which may ignite the dust or fumes Always wear safety glasses and rubber soled non slip shoes Use of this safety equip ment may prevent serious injury These instructions are intended to famili...

Страница 3: ...ituations 5 Always wear safety glasses and rubber soled non slip shoes Dust mask non skid safety shoes hard hat or hearing protection must be used for appropriate conditions 6 Rubber glove inserts should be worn for health and safety reasons Sewer lines are unsanitary and may contain harmful bacteria 7 Check to make sure pipes are not electrically hot In some cases ground circuits may be returned ...

Страница 4: ...od condition Using lighter cords can result in severe power loss and motor overheat ing 12 Be careful when inspecting drains where cleaning chemicals have been used Avoid direct contact with corrosive drain clean ers Drain cleaning chemicals can cause serious burns as well as damage the cable Neutralize or remove corrosive drain cleaners in the drain before starting the job 13 Do not operate machi...

Страница 5: ...amming value Press to start stop video recording Increment a programming value Open the video trash utility from the video viewer Rotate the record image 90 degree While in live image mode press this bottom to set Brightness Contrast and Grey scale GEN EYE MICRO SCOPE2 COMMAND MODULE The Command Module should not be used in wet locations or in the rain as moisture may cause damage to the unit THE ...

Страница 6: ...in menu Factory Default Reset and Firmware Version 1 From the main menu use the arrow buttons to scroll to the Fac tory Default icon and press OK to open it 2 There are three rows of options in this menu The top row is the Factory Default reset icon To revert to factory settings highlight this icon with the arrow buttons and pres the OK button 3 The middle row is the abort function Press OK with t...

Страница 7: ...internal 4 hr battery will power the Micro Scope2 when AC power is not available Recharging time varies depending upon air tempera tures and the condition of the battery The battery does not have to be deep cycled but the battery may have to be replaced over time de pending on usage and conditions The battery can be recharged from either an AC outlet or from an AC inverter outlet in your car or tr...

Страница 8: ...pe conditions In some cases white or lighter colored objects may cause the picture to flare or wash out If this happens simply adjust the light level until a good picture is achieved 8 Push the camera slowly and carefully during the inspection taking note of the pipe condition for possible hazards that may entangle or damage the camera on entry or retrieval 9 When negotiating a corner care should ...

Страница 9: ...dule is turned up Check cable for possible breaks or intermittent open circuits by flexing the cable Disconnect main power and contact the factory service depart ment No Picture Lights OK Check Monitor power switch is ON Check to make sure the power source is live for 120 volt AC or that the battery is charged Check the interface cord for possible damage or intermittent problem by flexing the cabl...

Страница 10: ... to fully recharge battery Cold weather can reduce battery life Keep unit warm in cold weather Do not charge the battery in extreme weather temperatures below 30 F or above 104 F When charging via DC you must use the AC inverter Battery is worn out and need to be replaced Disconnect the main power source and contact the factory ser vice department NOTE Command Module is shipped without a charge Ch...

Отзывы: