7 / 10
WARNING!
Please do not connect the modem with another product's supply line.
Risk of fire and injury due to short circuit!
Please comply with local regulations when determining power cable diameters.
Please supply the power line from a fuse.
WARNING!
The product is subject to the European Directive 2012/19 / EU as it is included in the electronic product
category.
It cannot be considered as domestic waste.
You can leave the product in electronic waste collection areas.
Follow all local and applicable laws and regulations.
WARNING!
There is no internal fuse inside the product.
External fuses must be used on all supply lines.
SYNC ROOM THERMOSTAT AND RECEIVER
Each room thermostat is matched with a modem inside the factory. In case of any signal loss, you can perform the
matching by following the steps below.
Press the button for 3 seconds when room thermostat is off. You will see the heating calibration setting menu,
after you press one more time, you will see sync menu which written as “Adr”.
Primarily press the sync button of receiver for 2 seconds and see blinking green light of receiver. Then turn up the
button to right or left way.
Green light on the receiver will be stable and signal sound will be heard from receiver.
Room Thermostat and Receiver synced.
ROOM THERMOSTAT HEATING CALIBRATION
If you want to take the temperature on your thermometers in your living space as reference, you need to calibrate
your room thermostat. For this:
Press the button for 3 seconds when the device is off.
In order to see the desired temperature, set the temperature difference by turning the button to right or left. This
o
o
value can be set between -8 C and +8 C.
Exit the menu by pressing the button.
o
Note:
Recommended tempreture calibration is “0.0 C”.
generallife.com.tr