General Ecology, Inc. —
6
STEP 5
Mounting Bracket Installation
Check location for clearances and ease of access.
STEP 4
Hose Connections to Vessel
Make sure the outlet hose going to your faucet is connected to the center outlet port.
2.
Attach Connector Hose from the
kitchen faucet or installed Esprit
Faucet to top fitting of Outlet Port
(center outlet port). Tighten
2
to
w
turn beyond finger tight (
Fig. 14
).
Do not over tighten.
1.
Attach Connector Hose from the
cold water supply valve to the
Inlet Port on the Housing. Tighten
connections (
Fig. 13
).
Figure
14
outlet
water flow – out
to faucet
Figure
13
inlet
water flow – in from cold
water supply
1. Install Residential Mounting
Bracket or Clip Mounting Bracket.
(
Figs. 15-16
) Position Mounting
Bracket on the inside wall of the
sink cabinet. Use the Self-Tapping
Screws to securely install the
Bracket. Make sure the Bracket
location permits access to the
cold water valve location and easy
access for Cartridge changes.
2. Mount unit on the Residential
Bracket by placing the V-Clamp
over the raised section on top of
the Bracket (
Fig. 17
).
3 Mount unit on the Clip Bracket as
shown (
Fig. 18
). A cotter pin or
other pin, or wire can be inserted in
the bracket, above the V-clamp to
lock in place (see arrow) after unit
is completely on the bracket.
Figure
16
Figure
15
Figure
17
INSERT HERE
Figure
18
STEP 6
Operation
4. Open the X-1F Faucet to allow
air to exhaust slowly. Open
Valve on cold water service
line (
Fig. 19
). Check for leaks.
Allow water to run for several
minutes to clear line and system
of air and any loose materials.
Please note that for the first few
days you may see entrapped air
bubbles within the water. This is
perfectly normal and will cease
after the unit has processed
several gallons of water. Also,
some black “fines” from inside of
cartridge may flow with the first
few gallons of water. These are
harmless, if consumed, or may
be discarded.
Figure
19
QUESTIONS?
Call 1-800-441-8166
for Customer Service