GENERAL ECOLOGY Seagull IV X-1KF Скачать руководство пользователя страница 5

1.

 Loosen faucet stem nut and 

remove the split washer for step 
4 of installation keeping the 
escutcheon plate in-place.

2.

 Attach connector hose to faucet 

stem and tighten 

2

 to 

w

 turn 

beyond finger tight.

3.

 Drop connector hose through 

mounting hole in counter top. 

4.

 Slide split washer (

Fig. 11

)  

with indented surface facing up 
(used to center the faucet in the 
mounting hole), between bottom  
of countertop and faucet stem nut.

5.

 

Slide the open end of the supplied 
wrench onto the faucet stem 
beneath sink. Slide the wrench 
up the stem; fitting the wrench on 
to the stem nut, (

Fig. 12

) position 

and orient the faucet, then turn the 
wrench to secure faucet.

General Ecology, Inc. —

 5

1. Install Connector Hose.

 

  If kitchen faucet has 

2

” pipe thread 

stem, connect 

2

” Female Pipe 

Thread x 

a

” Compression Fitting to 

cold side of kitchen faucet (

Fig. 9

). 

Install Connector Hose to this Fitting. 
Tighten 

2

 turn beyond “finger tight.” 

Do not overtighten.

2. Install Connector Hose.

 

If kitchen faucet has 

a

” tubing 

tails, install a Compression Fitting 
(owner supplied), to cold water side 
being sure to seat “self-Align” Nut 
and Ferrule in proper orientation 
(

Fig. 10

). Install Connector Hose 

to Fitting. Tighten 

2

 turn beyond 

“finger tight.” Use wrench to hold 
Fitting—do not twist faucet tail.

 

STEP 3

 Connecting to existing Kitchen Faucet Configurations

Follow this step if you are using the X-2KB model

Figure

 

10

Figure

 

9

General Ecology, Inc. Esprit Faucet is designed to fit a mounting hole 1

a

” diameter. 

If a suitable hole is not available, prepare by referring to Mounting Hole Pattern on 

page 7

.

STEP 3

 Installation and Connecting X-1KF/X-2KF with Esprit™ Faucet

Follow this step if you are using the supplied Esprit faucet. 

Cut out Mounting Pattern supplied 
on the following page and use for 
rough positioning. Tape pattern in 
place, then for final positioning place 
Faucet on pattern on top of sink 
and check for correct position of 
faucet body, spout and lever. Make 
sure of clearance, above and below 
sink before drilling mounting hole. 
Porcelain sinks  require special 
care. For best results we suggest 
you contact your dealer or others 
with experience in making cutout 
in porcelain sinks. We have had 
good success with the following 
procedure. First cover the area 
being penetrated with masking or 
duct tape and from beneath drill a 

z

” pilot hole upward...a 

v

” hole and 

then a 1

8

” hole and finally the 1

a

” 

hole necessary to mount the faucet. 
For man-made and stone products 
consult counter top manufacturer’s 
guidelines. For stainless steel sinks 
use a “Greenlee” type punch / die 
tool. If you do not have a “Greenlee” 
punch and are installing on stainless, 
follow the same procedure as on 
porcelain/cast iron sinks. Be sure 
sink ledge at drill hole is “flat” and 
burr free.

Split 
Washer

Faucet 

Wrench

Faucet 

Stem Nut

Escutcheon 

Plate

Connector 
Hose

Figure

 

12

a

 

fitting  

not 

included

Faucet Wrench

Countertop

Indented Surface 

Facing Up

Figure

 

11

Содержание Seagull IV X-1KF

Страница 1: ...on the following pages Follow steps 1 through 6 for installation Steps A through F found on page 8 are additional instructions for cartridge changing Configuration dimensions are shown on page 7 Gener...

Страница 2: ...ication Cartridge 1 788000 5 X 1 Pressure Vessel 1 6 Gasket Housing Blue 1 710550 7 V Clamp for Housing 1 710534 No Description Qty Part No 8 Wing Nut for V Clamp 1 710032 9 Esprit Designer Faucet 1 8...

Страница 3: ...ication Cartridge 1 789000 5 X 2 Pressure Vessel 1 6 Gasket Housing Blue 1 710550 7 V Clamp for Housing 1 710534 No Description Qty Part No 8 Wing Nut for V Clamp 1 710032 9 Esprit Designer Faucet 1 8...

Страница 4: ...3 Figure 1 Seagull IV X 1KF X 2KF Systems you may need to purchase a Compression T with a male fitting to install in the existing cold water line See parts illustration on page 2 1 Attach a Connector...

Страница 5: ...X 2KB model Figure 10 Figure 9 General Ecology Inc Esprit Faucet is designed to fit a mounting hole 1a diameter If a suitable hole is not available prepare by referring to Mounting Hole Pattern on pa...

Страница 6: ...mits access to the cold water valve location and easy access for Cartridge changes 2 Mount unit on the Residential Bracket by placing the V Clamp over the raised section on top of the Bracket Fig 17 3...

Страница 7: ...faucet surfaces properly use a small amount of a nonabrasive liquid detergent and a soft wet cloth Gently rub the soiled surface until the dirt is removed Then rinse clean and wipe with a dry soft cl...

Страница 8: ...to Step 6 on Page 7 to place unit back in service If you have difficulty separating the upper and lower halves of the pressure vessel water pressure can help Turn off cold water supply remove the V cl...

Отзывы: