Additional Features
Port Monitoring & Port Alerts
076R172-000
SpectraComm ADT
5-21
Issue 6
Installation and Operation Manual
Port Alert Configuration
1. To review the available port alert commands, type:
configure ports alert ?
The following Help screen appears.
2. Enable the port monitor by tying the following commands:
configure ports monitor enable port
[#] or
all
3. Add a port alert string (up to 30 characters) by typing the following command:
configure ports alert add port
[#]
[“quoted string”]
4. Continue to add port alert strings to the same port if needed. Up to five alert strings are allowed
per port.
5. Configure the port to select for forwarding either case-sensitive matches (default) or as case-
insensitive matches. Case-sensitive matches have the least impact on throughput since the SC-
ADT will not convert case mismatches.
•
(Default) To configure the port for case-sensitive matches with the attached device, type:
configure ports alert match-case port
[#]
•
To configure the port for case-insensitive matches with the attached device, type:
configure ports alert ignore-case port
[#]
6. To check the port alert configuration for the port, type:
show ports alert port
[#]
An example display is shown below.
through
for each port individually, as needed. As an alternative, copy all
of the alert strings configured for one port to another port as follows:
•
Type
configure ports alert copy port
[#]
port
[#]
(where the first argument is the “from” port number, followed by the “to” port number).
•
Type
Y
at the confirmation prompt to copy the alert string as designated.
___________Help for "configure ports alert "______________________
add
Add port alert string; requires 2 parameter(s)
clear
Clear all alert strings for a port; requires 1 parameter(s)
copy
Copy alert strings from port to port; requires 2 parameter(s)
delete
Delete port alert string; requires 2 parameter(s)
ignore-case Ignore case of port alert strings; requires 1 parameter(s)
match-case
Match case of port alert strings; requires 1 parameter(s)
Port alert info for port8
---------------------------------------------------------------
Port Description: ACME Model 1
Match Case: NO
Monitor State: ON
Port alert compare strings:
------------------------------
"error"
"boot"
Содержание SC-ADT 16 Por
Страница 6: ...iv SpectraCommADT 076R172 000 Installation and Operation Manual Issue 6 Table of Contents...
Страница 92: ...Additional Features SNMP Traps 5 24 SpectraCommADT 076R172 000 Installation and Operation Manual Issue 6...
Страница 105: ......
Страница 106: ...The Best Connections in the Business...