Alarms Signals 

Thermal protection alarm *** Wait for automatic reset *** 

In the case of a possible use of the plant obstructed  or dirty filter, a thermal switch of protection 
stops the operation of the control unit to prevent overheating  that could damage it.  
The control unit can be reused after about 30 minutes of stop at the end of which it will 
automatically return to stand-by

 

 

 

Alarm continuous working *** Press Reset *** 

You set a time of continuous operation which, if exceeded, the control unit goes into protection. 

Set by default at 45 minutes. 

To reset the main vacuum unit in stand-by mode requires a long press of the reset button. 
The set time can be changed and customized according to your needs, follow the instructions in Chap. 6.1. 

 
Alarm accidental start *** Press Reset *** 

If the main vacuum unit is accidentally turned on for more than 7 times in one minute, the same goes for 

protection. 

Once the filter cleaning requires a long press of the reset button to reset the vacuum unit in stand-by 

mode. 

 
Alarm obstructed suction  *** Press Reset *** 

In cases where the system is obstructed or the main vacuum unit functions with all the vents closed, a 

protection system prevents its function. 

For the first two signals can be switched on again the control unit by simply sending a new command  

wireless or by removing and reinserting the working tube in the socket. 

After the third consecutive signal requires a long press of the reset button to reset the controller in stand-

by mode and re-enter the working tube in the suction inlet   

5.6.3.

 

Signaling failures 

Self-Cleanig Fault *** Press Reset and contact Assistance Centre *** 

The control unit reports that there is a fault in the system of self-cleaning filter 

To restore the self-cleaning system is necessary to call the authorized service center, by contacting the free 

number indicated on the nameplate of the unit. 

In automatic mode, the control unit sets the functionality of manual filter cleaning, see chap. 5.6.1 for 

maintenance. 

one time of cleaning the filter requires a long press of the reset button to reset the controller in stand-by 

mode. 

 
 
 

Содержание i1250

Страница 1: ...Residential Vacuum Unit GDA Series Rev 15 01 Use and Maintenance Manual...

Страница 2: ......

Страница 3: ...um unit 15 3 Handling and unpacking 17 4 Installation 18 4 1 Choice of installation position for main vacuum unit 18 4 2 Dimension and technical data 19 4 3 Installation of main vacuum unit 19 4 4 Rev...

Страница 4: ...sed of chapters divided into sections identified by a progressive numbering system at the start of each different topic Italian is the language of the first release The table of contents lists the cha...

Страница 5: ...tarting to use the system in any way whatsoever the instructions given in this manual supplied must be carefully and completely together with the indications provided directly on the system with safet...

Страница 6: ...ing plate is on the right side of the central vacuum For all requests for technical assistance in addition to details of the problem encountered customers are asked to inform the manufacturer of all s...

Страница 7: ...ifications or adaptations of the vacuum unit are permitted Any use whatsoever other than the use for which the product has been designed represents improper use that may damage the vacuum unit and con...

Страница 8: ...s of flour printer toner building site dust fine powder cement or plaster Unplug the unit from the 230V power supply wall socket in these cases I If the main vacuum unit receives an impact II If maint...

Страница 9: ...T1600 T1750 Maximum surface area mq 120 300 120 300 420 700 300 420 700 Smart electronics NO NO YES YES YES YES YES YES YES Self cleaning function NO NO NO NO NO NO YES YES YES Wireless YES YES YES YE...

Страница 10: ...Use and Maintenance Manual Residential Vacuum Units Product Description 10 2 3 Exploded diagram of main vacuum unit mod 1000 1250 Figure 2...

Страница 11: ...ALL BRACKET 10 0102320 GASKET LOWER 1000 1250 11 0901031 ENGINE 1000W 1000 11 0901036 ENGINE 1250W 1250 12 0902200 SOUNDPROOF HEADSET FOR ENGINE 1000 1250 1000 1250 13 0902205 GASKET FOR SOUNDPROOF HE...

Страница 12: ...Use and Maintenance Manual Residential Vacuum Units Product Description 12 2 5 Exploded diagram of main vacuum unit mod 1000 1250 Figure 3...

Страница 13: ...00 1750 8a 0102192 GRID FOR UNITS MOD 1600 1750 complete of sponge protection cod 0102284 and nr 1 soundproofing cylinder for lateral carter cod 0102283 1600 1750 8b 0102192 GRID FOR UNITS MOD 1600 17...

Страница 14: ...d while programming to memorize the new parameters 6 RESET button After maintenance operations press this button to zero the alarm timer 7 DISPLAY window While programming this window shows the values...

Страница 15: ...se accessories are not included but are sold separately in the central vacuum Telescopic extension The telescopic extension has an adjustable length can be connected to different brushes for cleaning...

Страница 16: ...Use and Maintenance Manual Residential Vacuum Units Product Description 16 Figure 7...

Страница 17: ...ersonal protective equipment Failure to use the appropriate DPI during handling and unpacking exhibits the operator to the risk of crushing the foot for stability loss Failure to use the glove does no...

Страница 18: ...vided that the vacuum unit is always protected from inclement weather The selected position must have a clear space around the main vacuum unit and well lit so as to make easy maintenance and repair T...

Страница 19: ...0 370 370 370 4 3 Installation of main vacuum unit Ater moving the main vacuum unit still packed to the selected room proceed to unpack paying attention to the indications on the package and begin the...

Страница 20: ...ections frontally into the corresponding recesses in the wall bracket and applying pressure until they click in Figure 10 5 Connect the system pipe to the main vacuum unit with the sleeve provided tig...

Страница 21: ...to the main vacuum unit 9 For the Intelligence and Total versions connect the 5 poles yellow green grey white blue for the direct auxiliary signal to the embedded user interface The use of this signa...

Страница 22: ...the unit from the 230 V power supply wall socket To reverse the suction connector proceed as follows 1 Unscrew the screws and remove the reversible support inlet figure 13 2 Rotate the reversible supp...

Страница 23: ...em check can be made 1 after the vacuum pipes have been installed 2 before floors are laid The installation technician and the site manager can therefore offer users a guarantee of perfect operation a...

Страница 24: ...eiver It is therefore sufficient to press the start stop button on the BRAVA Wireless Handle to turn the main vacuum unit on and off Figure 17 IMPORTANT It is not necessary for the suction points to b...

Страница 25: ...essary to replace one of these it is necessary to reset the memory and do a new programming To reset refer to the Manual of Use and Maintenance of the handle in attached to the packaging of this 5 5 S...

Страница 26: ...to reset the machine in stand by mode If the vacuum unit indicates to empty the dust container and the same is not particularly full you can change the preset time from the factory increasing it Filt...

Страница 27: ...s for protection Once the filter cleaning requires a long press of the reset button to reset the vacuum unit in stand by mode Alarm obstructed suction Press Reset In cases where the system is obstruct...

Страница 28: ...lt Models W1250 i1250 i1600 i1750 T1250 T1600 end T1750 hours 1 10 40 SELF CLEANING Models T1250 T1600 end T1750 Min 30 45 240 CONTINUOS OPERATION entire range Min 30 45 600 5 7 2 Personalization of...

Страница 29: ...age appears To leave this display press the RESET button Continuos operation This procedure is used to modify the parameter that controls alarm operation set by default at 45 minutes Enter the USER ME...

Страница 30: ...s see chap 5 7 2 6 1 Emptying the dust container The dust container must be emptied regularly every 3 6 months depending on frequency of use and acquired experience The dust container must be washed w...

Страница 31: ...undamaged and to check if it needs washing if washed the filter must be dry before being replaced It is advisable to keep a spare filter available for cleaning operations INSTRUCTION 1 Unplug the unit...

Страница 32: ...ust be completely dry before being refitted Do not throw the inverted red cone away replace it correctly above the dust container Do not use compressed air The filter must be replaced after 2 years of...

Страница 33: ...ut out breaker that stops the motor in case of overheating In case of unit stop due to thermal cut out breaker allow the motor to cool down to normal operating temperature about 25 30 minutes Then tra...

Страница 34: ...e g clogged filter full dust container partial obstruction of a brush or flexible hose etc IF THE MAIN VACUUM UNIT STILL OPERATES INCORRECTLY CONTACT THE AUTHORIZED ASSISTANCE SERVICE OR YOUR DEALER...

Страница 35: ...E MAIN VACUUM UNIT STILL OPERATES INCORRECTLY CONTACT THE AUTHORIZED ASSISTANCE SERVICE OR YOUR DEALER INDICATING THE SERIAL NUMBER AND MODEL OF YOUR SYSTEM 9 Repairs It is absolutely forbidden to car...

Страница 36: ...on recycling procedures for this product contact your local authority your local waste disposal agency or the dealer from which the product was purchased Before performing any procedure for the sale a...

Страница 37: ...CEI EN 60335 2 2 CEI EN 62233 Electromagnetic Compatibility Directive 2004 108 CE EMC CEI EN 55014 1 CEI EN 55014 CEI EN 61000 3 2 CEI EN 61000 3 3 Pressure Equipment Device 97 23 CE PED only fot Tota...

Страница 38: ...with Certified Quality System UNI EN ISO 9001 2008 General D Aspirazione via del Lavoro 9 47035 San Mauro Pascoli FC Tel 0541 93 10 12 Fax 0541 933763 info generaldaspirazione com www generaldaspirazi...

Отзывы: