Use and Maintenance Manual
Residential Vacuum Units
>>> Residential Vacuum Units Installation
19
4.2.
Dimension and technical data
WIRELESS
INTELLIGENCE
TOTAL
Model
W100
W1250
I1000
I1250
I1600
I1750
T1250
T1600
T1750
Height (mm)
600
940
600
940
1041
1041
1085
1186
1186
Diameter (mm)
300
300
300
300
300
300
300
300
300
A – Minimun (mm)
40
40
40
40
40
40
40
40
40
B (mm)
357
695
357
695
695
695
695
695
695
C (mm)
194
194
194
194
104
104
339
249
249
D (mm)
210
210
210
210
210
210
210
210
210
E
(mm)
370
370
370
370
370
370
370
370
370
4.3.
Installation of main vacuum unit
Ater moving the main vacuum unit still packed to the selected room, proceed to unpack paying attention to
the indications on the package and begin the installation steps as follows:
1.
Provide a 230 V SHUKO power supply socket.
2.
Use the template provided to mark the desired position. Verify that the position does not interfere with
the passage of electric cables in the wall. (Figure8).
3
. Fix the wall bracket to the wall in the marked position using the expansion plugs provided, inserting the
support cylinders between the bracket and the wall (not necessary for installation in box). (Figure 9).
For installation on plasterboard walls, use specific fixing plugs.