Generac Power Systems PWRell 0009890 Скачать руководство пользователя страница 7

Safety Rules & General Information

Owner’s Manual for Generac PWRCell Battery

3

Electrical Hazards

(000104)

DANGER

Electrocution. Water contact with a power 
source, if not avoided, will result in death 
or serious injury.

(000604)

DANGER

Electrocution. PWRcell Battery front cover should be 
removed by a qualified technician only. Removing 

the front cover could result in death, serious injury, 

equipment Or property damage.

 
 

(000145)

DANGER

Electrocution. In the event of electrical accident,  
immediately shut power OFF. Use non-conductive  
implements to free victim from live conductor. Apply  
first aid and get medical help. Failure to do so will  
result in death or serious injury.

(000599)

DANGER

Electrocution. Turn battery disconnect OFF and 
de-energize REbus before touching terminals.


Failure to do so will result in death, serious injury,
equipment and property damage.

 

 
 

(000152)

DANGER

Electrocution. Verify electrical system is
properly grounded before applying power.
Failure to do so will result in death or serious
injury.

(000188)

DANGER

Electrocution. Do not wear jewelry while 
working on this equipment. Doing so will 
result in death or serious injury.

(000187)

WARNING

Electrocution. Potentially lethal voltages are generated
by this equipment. Render the equipment safe before
attempting repairs or maintenance. Failure to do so
could result in death or serious injury.

(000155a)

WARNING

Electric shock. Only a trained and licensed electrician 
should perform wiring and connections to unit. Failure 
to follow proper installation requirements could result in 
death, serious injury, and equipment or property damage.

Battery Hazards

(000162)

WARNING

Explosion. Do not dispose of batteries in a fire. 
Batteries are explosive. Electrolyte solution can cause 
burns and blindness. If electrolyte contacts skin or eyes, 
flush with water and seek immediate medical attention.

WARNING

(000228)

Environmental Hazard. Always recycle batteries at an 
official recycling center in accordance with all local 
laws and regulations. Failure to do so could result in 
environmental damage, death, or serious injury.

(000601)

CAUTION

Equipment damage. Use ONLY manufacturer approved 
battery modules. Using any other module could damage
Generac PWRcell Battery and may void the warranty.

 
 

Always recycle batteries in accordance with local laws and 
regulations. Contact your local solid waste collection site 
or recycling facility to obtain information on local recycling 
processes. For more information on battery recycling, visit 
the Battery Council International website at:  

http://batterycouncil.org

Fire Hazards

WARNING

(000603)

Fire hazard. Never attempt to fight a fire yourself. 
Evacutate the building and contact emergency services. 
Inform dispatcher that lithium-ion batteries are in the 
building. Failure to do so could result in death, serious 
injury, or property or equipment damage.

Содержание PWRell 0009890

Страница 1: ...Loss of life This product is not intended to be used in a critical life support application Failure to adhere to this warning could result in death or serious injury Register your Generac product at...

Страница 2: ...ion is performed promptly and to have the equipment checked periodically by an ASD Normal maintenance service and replacement of parts are the responsibility of the owner operator and as such are not...

Страница 3: ...rial Number Locations 6 Unit Dimensions 6 Component Locations 7 Battery Disconnect Switch 7 Battery Status LED 7 About Generac PWRcell Battery 8 Communication 8 System Operational Modes 8 Inverter Con...

Страница 4: ...iv Owner s Manual for Generac PWRcell Battery This page intentionally left blank...

Страница 5: ...m on how to correctly start operate and stop the unit in case of emergency Safety Rules The manufacturer cannot anticipate every possible cir cumstance that might involve a hazard The alerts in this m...

Страница 6: ...d result in death serious injury and equipment or property damage IMPORTANT NOTE See individual unit specifications for required maintenance and run times pertaining to use Connecting Generac PWRcell...

Страница 7: ...ould result in death or serious injury 000155a WARNING Electric shock Only a trained and licensed electrician should perform wiring and connections to unit Failure to follow proper installation requir...

Страница 8: ...Shutdown press and hold Shutdown A Safety shutdown LED B will illuminate and LCD screen C will indicate Safety Shutdown has been initiated REbus Inverter Internet Shutdown hold 009656 A C B Figure 1 1...

Страница 9: ...Ebus Communication Protocol REbus DC Nanogrid Voltage Input Output VDC 360 420 Round Trip Efficiency DC to DC 96 5 Temperature Operating Temperature Limits F C 41 113 5 45 Recommended Temperature Rang...

Страница 10: ...ameplate Record the information from these tags so it is available if the tags are lost or damaged When ordering parts or requesting assistance you may be asked to provide this information A 0009891 F...

Страница 11: ...battery monitoring system BMS electronics NOTE Battery Disconnect can be locked in the OFF position if required NOTE Turn Battery Disconnect OFF whenever system will be powered down and left inactive...

Страница 12: ...enerac PV Link Optimizers F Grid C Generac PWRcell Battery G Loads D REbus H Protected Loads Communication All communication between REbus devices takes place over the REbus conductors using Power Lin...

Страница 13: ...able for Self Supply and other non backup uses but lowers the islanding reserve in the event of an outage Raising this setpoint lowers capacity available for Self Supply and related modes but increase...

Страница 14: ...rty damage While in Sleep Mode Generac PWRcell performs Power Searches at regular intervals During a Power Search Generac PWRcell wakes up energizes the REbus Nanogrid and scans for potential sources...

Страница 15: ...PWRcell Inverter and charging from the Gen erac PWRcell PV Link and other sources Manual Enable See Figure 2 7 If LED B lights solid red when Battery Disconnect switch is turned ON the Generac PWRcel...

Страница 16: ...12 Owner s Manual for Genera PWRcell Battery General Information This page intentionally left blank...

Страница 17: ...ed air or water NOTE Allow filter to dry before reinstalling 5 Reinstall filter If air filter is damaged contact Generac Customer Service at 1 888 GENERAC 1 888 436 3722 or visit www gen erac com for...

Страница 18: ...Dealer shall prepare a written decommissioning plan that provides the overview of the decommissioning process developed specifically for the Generac PWRCell Battery system that is to be decommissioned...

Страница 19: ......

Страница 20: ...ghts reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W29290...

Отзывы: