Generac Power Systems PWRell 0009890 Скачать руководство пользователя страница 18

14

Owner’s Manual for Generac PWRcell Battery

Maintenance

Decommissioning

WARNING

(000228)

Environmental Hazard. Always recycle batteries at an 
official recycling center in accordance with all local 
laws and regulations. Failure to do so could result in 
environmental damage, death, or serious injury.

WARNING

(000654)

Environmental Hazard. Decommissioning must be 
performed by qualified personnel. Decommissioning 
performed by unqualified personnel could result in
environmental damage, death, or serious injury.

Generac PWRCell Battery modules will be required to be 
decommissioned at the battery module end of life stage 
or  if  the  Generac  PWRCell  Battery  system  will  be 
removed  from  the  premises  in  accordance  with  these 
instructions,  the  requirements  in  NFPA  855,  and  all 
applicable  code  requirements.  The  authority  having 
jurisdiction  (AHJ)  shall  be  notified  prior  to  the 
decommissioning  of  the  Generac  PWRCell  Battery 
system.

Decommissioning Plan.

The owner of the Generac PWRCell Battery system and 
the  qualified  Generac  Service  Dealer  shall  prepare  a 
written decommissioning plan that provides the overview 
of  the  decommissioning  process  developed  specifically 
for  the  Generac  PWRCell  Battery  system  that  is  to  be 
decommissioned.  The  decommissioning  plan  shall 
provide  the  requirements  and  methods  necessary  to 
safety discharge the stranded energy in battery modules 
and the proper removal from the installation site including 
the  transportation  and  recycling  process  for  the  battery 
modules.    
After  the  Generac  PWRCell  Battery  system  has  been 
decommissioned,  a  decommissioning  report  shall  be 
prepared by the owner of the Generac PWRCell Battery 
system  and  the  qualified  Generac  Service  Dealer 
indicating the date the system was decommissioned, the 
final  results  of  the  decommissioning  process,  and  any 
issues  that  were  identified  during  the  decommissioning 
process  and  the  required  measures  taken  to  resolve 
those issues.

Battery Recycling

Always recycle batteries in accordance with local laws and 
regulations. Contact your local solid waste collection site 
or recycling facility to obtain information on local recycling 
processes. For more information on battery recycling, visit 
the  Battery  Council  International  website  at: 

http://

batterycouncil.org

Содержание PWRell 0009890

Страница 1: ...Loss of life This product is not intended to be used in a critical life support application Failure to adhere to this warning could result in death or serious injury Register your Generac product at...

Страница 2: ...ion is performed promptly and to have the equipment checked periodically by an ASD Normal maintenance service and replacement of parts are the responsibility of the owner operator and as such are not...

Страница 3: ...rial Number Locations 6 Unit Dimensions 6 Component Locations 7 Battery Disconnect Switch 7 Battery Status LED 7 About Generac PWRcell Battery 8 Communication 8 System Operational Modes 8 Inverter Con...

Страница 4: ...iv Owner s Manual for Generac PWRcell Battery This page intentionally left blank...

Страница 5: ...m on how to correctly start operate and stop the unit in case of emergency Safety Rules The manufacturer cannot anticipate every possible cir cumstance that might involve a hazard The alerts in this m...

Страница 6: ...d result in death serious injury and equipment or property damage IMPORTANT NOTE See individual unit specifications for required maintenance and run times pertaining to use Connecting Generac PWRcell...

Страница 7: ...ould result in death or serious injury 000155a WARNING Electric shock Only a trained and licensed electrician should perform wiring and connections to unit Failure to follow proper installation requir...

Страница 8: ...Shutdown press and hold Shutdown A Safety shutdown LED B will illuminate and LCD screen C will indicate Safety Shutdown has been initiated REbus Inverter Internet Shutdown hold 009656 A C B Figure 1 1...

Страница 9: ...Ebus Communication Protocol REbus DC Nanogrid Voltage Input Output VDC 360 420 Round Trip Efficiency DC to DC 96 5 Temperature Operating Temperature Limits F C 41 113 5 45 Recommended Temperature Rang...

Страница 10: ...ameplate Record the information from these tags so it is available if the tags are lost or damaged When ordering parts or requesting assistance you may be asked to provide this information A 0009891 F...

Страница 11: ...battery monitoring system BMS electronics NOTE Battery Disconnect can be locked in the OFF position if required NOTE Turn Battery Disconnect OFF whenever system will be powered down and left inactive...

Страница 12: ...enerac PV Link Optimizers F Grid C Generac PWRcell Battery G Loads D REbus H Protected Loads Communication All communication between REbus devices takes place over the REbus conductors using Power Lin...

Страница 13: ...able for Self Supply and other non backup uses but lowers the islanding reserve in the event of an outage Raising this setpoint lowers capacity available for Self Supply and related modes but increase...

Страница 14: ...rty damage While in Sleep Mode Generac PWRcell performs Power Searches at regular intervals During a Power Search Generac PWRcell wakes up energizes the REbus Nanogrid and scans for potential sources...

Страница 15: ...PWRcell Inverter and charging from the Gen erac PWRcell PV Link and other sources Manual Enable See Figure 2 7 If LED B lights solid red when Battery Disconnect switch is turned ON the Generac PWRcel...

Страница 16: ...12 Owner s Manual for Genera PWRcell Battery General Information This page intentionally left blank...

Страница 17: ...ed air or water NOTE Allow filter to dry before reinstalling 5 Reinstall filter If air filter is damaged contact Generac Customer Service at 1 888 GENERAC 1 888 436 3722 or visit www gen erac com for...

Страница 18: ...Dealer shall prepare a written decommissioning plan that provides the overview of the decommissioning process developed specifically for the Generac PWRCell Battery system that is to be decommissioned...

Страница 19: ......

Страница 20: ...ghts reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W29290...

Отзывы: