background image

350 kW

437.5 kVA

15%

20%

25%

30%

35%

% of Rated Load

1,209

2,329

3,429

4,467

Heat Rejection to Coolant( Full Load )

Coolant Capacity (total)

Max air temp to radiator º F

 (derates apply) 

Max ambient temperature º F 

(derates apply) 

Flow at Rated Power  ( cfm)

0.5 inches H2O

Combinations

581

711

784

Inst Dip 

kVA

958

0.16

0.23

kW

Cu Ft / Hr

Therms/Hr.

208 Volts 1.0 PF

480 Volts 1.0 PF

90.40%

90.70%

3.50%

34,400 for the 3 units    17,200 for each unit

175

Natural Gas 950  BTU /Cu.Ft

87.5

11.49

262.5

350

22.12

32.58

1,206,000 BTU/Hr. Total for the 2 units   1@ 700,000 btu/hr  1@ 506,000btu/Hr.

42.44

90.50%

15.4 gallons for the 2 units  77 Gallons per unit

0.18

3.1

CBA

0.5%

0.07

0.0078

80% Load

100%

90.70%

91.10%

90.90%

Engine Fuel Consumption @

350 kW

MPSG350

415

637

804

208 Volt Parallel Wye Network

480 Volt Series Wye Network

Rated Amps

1214

459

1098

890

120/208

Motor Starting

277/480

600

421

1 - 200 kW, 1 - 150 kW 

TOTAL SYSTEM PARAMETERS      

50%

Neg Sequence Reactance

Time Constant Seconds

Max Harmonics

Efficiency % @ 

Output Voltage 60 Hz.

Alternator Parameters

Sub Transient Reactance

526

Transient Reactance

Synchronous Reactance

Alternator Models

75%

25%

60% Load

1128

Exhaust Flow @ FL 

120  º F

Exhaust

1174 cfm  Total.    618 cfm +  556 cfm

4017 CFM for the 2 units   2257 CFM + 1760 CFM

Engine Cooling  

                  2.0% for every 1000 ft above 

Altitude 0.7% for every 100 m above

Exhaust Temperature ( Average)

Exhaust Outlet per engine

Power Adjustments

Temperature 2% for every 10 º C above 

                          1.0% for every 10 º F above 

Maximum External Press Drop on Rad

1 @ 4.0" NPT

140 º F

Inlet Cooling Air  CFM

Combustion Air Requirements

100% Load

Zero Sequence Reactance

Voltage Balance

Phase Sequence

1-200 kW plus 1 - 150 kW  520 mm PMG Generac Alternators

* Note:  Temperatures will require necessary derates be applied.   Unless otherwise noted, all data at 480 volt wye - 1.0 PF.

3500 Feet

 350 kW Standby

40 º C

104 º F

1066 Meters

Содержание MPSG350

Страница 1: ...85 link is also available n Flexibility The Modular Power systems flexibility allows for a wide variety of configurations including single or multiple automatic transfer switch arrangements roof application where better weight distribution is required and areas with specific height or depth limitations Since MPS gensets need not be located together space can be utilized wherever it is available Sm...

Страница 2: ...8 W x 24 D 1600 Amp 80 H x 48 W x 48 D 2600 3200 Amp Wire access top side bottom NEMA 3R or 4X Optional Wt 1250 lbs 1000 1600 Amp 1850 lbs 2600 3200 Amp Connection Cabinet Optional NEMA 12 3R 80 H x 48 W x 48 D Lug capacity 16 for Generator Controller GC 12 for ATS Each lug accepts 4 4 to 750 MCM see Dwg OD4482 Floor mounting Aluminum or Copper Wire compatible 4500 amp bus Sequence of Operations 1...

Страница 3: ...90 120 208 Motor Starting 277 480 600 421 1 200 kW 1 150 kW TOTAL SYSTEM PARAMETERS 50 Neg Sequence Reactance Time Constant Seconds Max Harmonics Efficiency Output Voltage 60 Hz Alternator Parameters Sub Transient Reactance 526 Transient Reactance Synchronous Reactance Alternator Models 75 25 60 Load 1128 Exhaust Flow FL 120 º F Exhaust 1174 cfm Total 618 cfm 556 cfm 4017 CFM for the 2 units 2257 ...

Страница 4: ...laced end to end side by side or wherever room is available The transfer switch or switches are generally placed close to the main electric service Consult State Federal and Local codes for specific installation requirements Power Connections are in one area in the left rear quadrant of the genset All controls are through a single 2 wire RS485 connection that can be daisy chained between generator...

Отзывы: