Owner’s Manual for Mobile Light Tower
27
Section 5: Troubleshooting
General Troubleshooting
Some of the more common problems are listed in the
table below. This information is intended to be a check or
verification that simple causes can be located and fixed.
It does not cover all types of problems. Refer to the OEM
engine operator’s manual for additional troubleshooting
information. Procedures that require in-depth knowledge
or skills should be referred to a GMASD.
If problems persist, contact Generac Mobile at 1-800-926-9768 for assistance.
(000139)
WARNING
Risk of burns. Allow engine to cool before
draining oil or coolant. Failure to do so could
result in death or serious injury.
General Troubleshooting Guide
Problem
Possible Cause
Solution
Low oil pressure
shutdown
Low oil level
Verify oil level on dipstick. Add oil, if needed.
Oil leaking from engine
Visually inspect the engine for leaks.
Oil pressure switch failure
Refer to OEM engine operator’s manual to identify corrective action.
High coolant temperature
shutdown
Low coolant level
Add coolant if needed. Allow engine to cool, then check coolant level in
radiator. Restart engine and check coolant temperature. Stop engine
immediately if coolant temperature is 210°F (99°C) or more.
Blockage in radiator
Inspect radiator shroud and ducting for blockage and remove any foreign
matter.
Leakage in coolant hoses,
engine block, or water pump
Inspect for visible leaks. Verify tension of water pump serpentine drive
belt.
Remove load on generator and restart engine. Verify coolant temperature
and shut engine down immediately if it starts to overheat. Refer to the
OEM engine operator’s manual for additional information on engine
overheating.
Unit cranks, but will not
start
Fuel level low
Check fuel level in tank.
Verify fuel pump operation.
Restricted air filter
Inspect air filter for blockage.
Refer to OEM engine operator’s manual for additional information.
Содержание MLT4150
Страница 16: ...12 Owner s Manual for Mobile Light Tower General Information This page intentionally left blank ...
Страница 24: ...20 Owner s Manual for Mobile Light Tower Operation This page intentionally left blank ...
Страница 30: ...26 Owner s Manual for Mobile Light Tower Maintenance This page intentionally left blank ...
Страница 34: ...30 Owner s Manual for Mobile Light Tower Wiring Diagrams AC Wiring ...
Страница 39: ...Owner s Manual for Mobile Light Tower 35 Wiring Diagrams DC Wiring Options If Equipped ...
Страница 41: ...Owner s Manual for Mobile Light Tower 37 Wiring Diagrams This page intentionally left blank ...
Страница 42: ...38 Owner s Manual for Mobile Light Tower Wiring Diagrams This page intentionally left blank ...
Страница 43: ......